Define your requirements
15925 Technical documents
-
F-C-8026
(Approval document / Penetration)
Double HVAC Line Set (pvc drain) (FS-ONE MAX only)
English
-
W-J-5042
(Approval document / Penetration)
Max. 12" steel, cast iron, or 6" copper with 1, 1-1/2, or 2" glass-fiber insulation (FS-ONE MAX only)
English
-
F-C-7042
(Firestop System Details / UL Detail Drawing)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle) (AS=1/8" to 7/8")
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-3092
(Approval document / Penetration)
Cable bundle (various cables) (PVC Sleeve) (AS=0" to 1-3/8")
English
Related products: CP 618 Firestop putty stick
-
F-E-1018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-3198
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CFS-SL RK Firestop Retrofit Sleeve Kit with CFS-PL Firestop Plug
English
Related products: CFS-SL RK Firestop retrofit sleeve kit
-
W-J-3199
(Firestop System Details / UL Detail Drawing)
Blank or cables through CFS-SL SK Firestop Sleeve Kit with CFS-PL Firestop Plug
English
Related products: CFS-SL SK Firestop sleeve kit
-
W-J-1128
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (CP 606 only) (AS=0" to 1-7/8")
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-5067
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall) (One Sided) (AS=1/4" to 1-1/8")
English
-
F-C-5004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)
English
-
W-J-1202
(Approval document / Penetration)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-J-5057
(Firestop System Details / UL Detail Drawing)
Max. 10" steel pipe with max. 3" thick glass-fiber insulation (AS=1/2" to 3/4")
English
Related products: CP 648-E firestop endless wrap strips
-
W-J-3060
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeved) (AS=0" to 1")
English
Related products: CP 618 Firestop putty stick, CP 606 Firestop acrylic sealant
-
W-J-3188
(Approval document / Penetration)
Cable bundle on Max. 20" wide steel cable rack through concrete wall or block wall assembly
English
Related products: CFS-BL Firestop Block, CP 620 Firestop foam
-
W-J-4016
(Approval document / Penetration)
Max. 18" x 6" Aluminum Spine Cable Tray with One max 2" ENT, and max. 22% cable fill (AS=1" to 4-1/2")
English
Related products: CFS-BL Firestop Block, CP 618 Firestop putty stick
-
W-J-1193
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" copper, steel conduit, or EMT (sleeved) (AS=0" to 3-7/8")
English
-
W-J-1215
(Approval document / Penetration)
Max. 3" steel, cast iron, steel conduit or EMT (CP 653 or CFS-SL GA L Speed Sleeve)
English
Related products: CP 606 Firestop acrylic sealant
-
F-E-7008
(Firestop System Details / UL Detail Drawing)
Max. 12" x 10" sheet metal duct through Concrete & Steel Joist Floor/Ceiling Assembly (UL G500 Series) (AS=0" to 1")
English
Related products: CP 606 Firestop acrylic sealant
-
F-E-5004
(Firestop System Details / UL Detail Drawing)
Max. 2" steel or copper pipe with nom. 3/4" AB/PVC through Concrete & Steel Joist Floor/Ceiling Assembly (UL G500 Series) (AS=1/2" to 1")
English
-
W-J-1191
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 2" steel, steel conduits, or EMT
English
Related products: CP 606 Firestop acrylic sealant