Define your requirements
15914 Technical documents
-
C-AJ-5044
(Firestop System Details / UL Detail Drawing)
Max. 3" steel or copper with Nom. 1" glass fiber insulation (max qty 4) (Max Opening = 24" x 8")
English
-
C-AJ-2054
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Polypropylene (PP, PP-R, PP-RCT) or max. 2" PVC-HR plastic pipe (closed or vented) with HILTI FS-ONE MAX firesetop intumsescent sealant and HILTI CP 648E firestop endless wrap strip + retaining collar.
English
Related products: CP 648-E firestop endless wrap strips
-
C-AJ-2659
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")
English
Related products: CP 618 Firestop putty stick
-
C-AJ-4035
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 4" Aluminum or Steel Open Ladder or Solid Back Cable Tray (CFS-BL Firestop Block) (AS=1" to 4")
English
Related products: CFS-BL Firestop Block
-
ASSET_DOC_LOC_16707969
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")
English
Related products: CFS-SP SIL Silicone-based joint sealant spray, Mineral wool
-
C-AJ-2065
(Firestop System Details / UL Detail Drawing)
Max. 125mm or 200mm Fusiotherm or Greenpipe SDR 11 or 7.4 PP (closed) (mfd. by Aquatherm) (AS=0" to 1")
English
Related products: CP 648-E firestop endless wrap strips
-
C-AJ-2022
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, ABS, FRPP, CPVC, RNC, or Aquarise CPVC (CP 648E wrap insert & FS-ONE MAX)
English
Related products: CP 648-E firestop endless wrap strips
-
C-AJ-4093
(CAD/BIM Typicals / Auto CAD drawing file)
Max 24" x 4" Aluminum or Steel Open Ladder or Solid Back Cable Tray(s) (CFS-BL Firestop Block) (AS varies)
English
Related products: CFS-BL Firestop Block
-
C-AJ-5265
(Approval document / Penetration)
Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve) (AS=1/4" to 1-5/8")
English
Related products: CP 606 Firestop acrylic sealant
-
C-AJ-2659
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")
English
Related products: CP 618 Firestop putty stick
-
C-AJ-2065
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)
English
Related products: CP 648-E firestop endless wrap strips
-
C-AJ-4071
(Firestop System Details / UL Detail Drawing)
Max. 24" x 6" Aluminum or Steel Open Ladder Cable Tray (FS-ONE MAX & Mineral Wool) (AS=0" to 6")
English
-
F-A-2013
(Firestop System Details / UL Detail Drawing)
Max. 2" PEX Tubing (SDR 9) (CP 680-P or PX Cast-In Device)
English
Related products: CP 680-P Cast-in firestop sleeve
-
C-AJ-5320
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated Max. 4" PVC or CPVC with 1" Glass Fiber (AS=0" to 1/2") or Max. 1" PVC or CPVC with 3/4" AB/PVC (AS=0" to 3/16")
English
Related products: CP 648-E firestop endless wrap strips
-
C-AJ-3152
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve)
English
Related products: CFS-BL Firestop Block, CP 618 Firestop putty stick
-
C-AJ-5184
(Approval document / Penetration)
Max. 24" steel or Max. 6" copper pipe with max. 3" thick mineral fiber insulation (AS=1/2" to 1-1/2")
English
-
C-AJ-2021
(Firestop System Details / UL Detail Drawing)
Max. 6" PVC, ABS, CPVC, Aquarise CPVC, 4" FRPP or RNC (optional hub on max. 4'" PVC or ABS)
English
Related products: CP 648-E firestop endless wrap strips
-
F-A-2005
(Approval document / Penetration)
CP 681 Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-2056
(Approval document / Penetration)
Max. 2" PP (Sch 80) (AS=3/16" to 7/16") (CP 648S wrap strip & FS-ONE MAX)
English
Related products: CP 648-S firestop single wrap strips
-
C-AJ-4017
(Approval document / Penetration)
Max. 24" x 4" Steel or Aluminum Open Ladder Cable Tray(s) (only one aluminum) (CP 637 Firestop Mortar)
English
Related products: CP 637 Firestop mortar