Save $60 on insertsUse code SYSTEM26Shop now

Firestop devices and sleeves

Explore our pre-formed firestop sleeves and cast-in devices, designed for easier installations and inspections when firestopping cable and pipe penetrations

20 Products

Filter
Cast-in firestop sleeve for metal decks CFS-CID MD P on white background
Description
One-step firestop cast-in sleeve for plastic pipe penetrations through corrugated metal deck slabs
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
Application temperature range
-5 - 50 °C
Product Class
Ultimate
Cast-in firestop sleeve for metal decks CFS-CID MD P on white background
Description
One-step firestop cast-in sleeve for plastic pipe penetrations through corrugated metal deck slabs
Application temperature range
-5 - 50 °C
Product Class
Ultimate
Cast-in firestop sleeve for metal decks CFS-CID MD M on white background
Description
One-step firestop cast-in sleeve for metal pipe penetrations through corrugated metal deck slabs
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
Application temperature range
-5 - 50 °C
Product Class
Ultimate
CP CFS-CID P 8", Cast-in device
Description
One-step firestop cast-in sleeve for 8" and 10" plastic and insulated metal pipe penetrations through floors. Place it and forget it
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
0 g/l
W-rating
Yes, with sealant
CP CFS-CID M 8" & 10", Cast-in device
Description
One-step firestop cast-in sleeve for 8" and 10" metal pipe penetrations through floors. Place it and forget it
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
0 g/l
W-rating
Yes, with sealant

New

CFS-MSL L Large modular sleeve with CFS-MSL P L singe plate


Description
Modular fire-rated cable pathway for optimal flexibility, cable capacity needs and retrofit ability
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
Product Class
Ultimate
Application temperature range
-5 - 50 °C
easy sleeve
Description
Pathway device for high-traffic cabling with optimal airflow control
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
Product Class
Ultimate
Application temperature range
-5 - 50 °C
Firestop Sleeve CFS-SL GA L
Description
Pathway device for high-traffic cabling with optimal airflow control
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
Product Class
Ultimate
Application temperature range
-5 - 50 °C
Sleeve_Kit_CFS-SL_SK_2"
Description
Two-step solution for sealing cable penetrations requiring a sleeved opening
Surface burning characteristics UL 723 (ASTM E84)
Flame spread: 10<BR>Smoke development: 15
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
4.9 g/l
Retrofit Sleeve Kit CFS-SL RK 2"
Description
Retrofit cable pathway device for firestopping existing cable applications
Surface burning characteristics UL 723 (ASTM E84)
Flame spread: 10<BR>Smoke development: 15
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
4.9 g/l
061915002 rev.tif
Description
Non-fire-rated cable pathway for smoke and acoustic sealing
Chemical basis
Polyurethane
Shelf life
Not relevant
Acoustics performance
Test report available
Firestop, metallic sleeve
Description
Conduit sleeve (1" diameter) with bushing and rigid attachment
No technical data available
L047387.tif


Description
One-step firestop cast-in solution for pipe floor penetrations
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
0.19 g/l
W-rating
Yes, with W-rating module
85296.tif
Description
One-step firestop cast-in sleeve for plastic pipe penetrations through floors. Place it and forget it
VOC Emission (LEED)
low-emitting material in LEEDv4 and 4.1 Rating System
LEED VOC
1.4 g/l
W-rating
Yes, with W-rating module

New

CFS-MSL P S Small modular sleeve frame offset
Description
Complimentary frame for fastening one modular fire sleeve to walls
Product Class
Ultimate
Application temperature range
-5 - 50 °C
Storage and transportation temperature range
-5 - 50 °C
CFS-MSL GPR Retrofit Gangplate 12x4 offset
Description
Surface-mounted gangplates for installing modular fire sleeves after drywall
Product Class
Ultimate
Application temperature range
-5 - 50 °C
Storage and transportation temperature range
-5 - 50 °C
CFS-MSL GPP Pre-install Gangplate 16x4
Description
Stud-mounted gangplates for installing modular fire sleeves before drywall
Application temperature range
-5 - 50 °C
Storage and transportation temperature range
-5 - 50 °C
Temperature resistance range
-30 - 75 °C
CFS-MSL GPA Gangplate adjustable offset
Description
Easily adjustable gangplate for varying capacity requirements in future cable additions
Product Class
Ultimate
Application temperature range
-5 - 50 °C
Storage and transportation temperature range
-5 - 50 °C

New

CFS-MSL FGR 24x19&quot; 4 row floor grid frame
Description
Floor grid frame for high-capacity, fire-rated cable installations through floors
Application temperature range
-5 - 50 °C
Storage and transportation temperature range
-5 - 50 °C
Temperature resistance range
-30 - 75 °C
Gangplate CFS-SL GP 16’’
Description
Stud- or surface-mounted gangplate to increase the capacity of firestop speed sleeves and simplify cable management
Maximum wall thickness
300
Product Class
Ultimate
Application temperature range
-5 - 50 °C