Read the latest articles and case studies by top engineering professionals.

Filters
Jesus A. Barreda, P.E., MBA
Reading time: < 15 minutes
Article

Behind the Rainscreen Facade: Are You Making One of the Most Common Subframing Design Mistakes?

Jesus A. Barreda, P.E., MBA
Reading time: < 15 minutes
The same panel loads can produce very different demands on the rainscreen subframing system. Why architects should verify how panel connections transfer those loads before accepting a subframing design.
Facade Structural Connections
Structural Connections
Annie Chen
Reading time: < 10 minutes
Article

What is the Hilti HDA Undercut Anchor and When Should Engineers Use It?

Annie Chen
Reading time: < 10 minutes
Learn how the updated ICC-ES ESR-1546 evaluation report enhances Hilti HDA performance, reduces edge and spacing requirements, and supports high-capacity static, seismic, and nuclear applications.
Baseplate
Structural Connections
Richard T. Morgan, P.E.
Reading time: < 10 minutes
Article

How Can ACI 318-19 Shear-Friction Provisions Be Used for Post-Installed Reinforcing Bars?

Richard T. Morgan, P.E.
Reading time: < 10 minutes
Provisions for Reinforced Concrete Design
Richard T. Morgan, P.E.
Reading time: < 5 minutes
Article

Shear Friction Design ACI 318-19 Anchoring-to-Concrete Provisions for Post-installed Reinforcing Bar

Richard T. Morgan, P.E.
Reading time: < 5 minutes
Utilize the anchoring-to-concrete provisions to resist shear using post-installed rebar
Ali Ahrabi
Reading time: < 5 minutes
Ryan Kolodetsky and Matthew Winston
Reading time: < 10 minutes
Annie Chen
Reading time: < 10 minutes
Article

Why Should Engineers Design Post-Installed Rebar Connections for Fire Exposure?`

Annie Chen
Reading time: < 10 minutes
How connection type, concrete cover, embedment depth, fire duration, and qualified bond data affect fire-safe concrete-to-concrete design
Structural Connections
Richard T. Morgan, P.E.
Reading time: < 10 minutes
Article

How Can ACI 318-19 Provisions be used for Extension Design of Post-Installed Reinforcing Bar?

Richard T. Morgan, P.E.
Reading time: < 10 minutes
Post-installed reinforcing bars evaluated per AC308 Table 3.8 can be designed using the ACI 318-19 development and lap splice provisions applicable to cast-in reinforcing bars. Development length (ℓd) and tension lap splice length (ℓst) are calculated using Chapter 25 requirements.
Facade Structural Connections
Structural Connections
Zachary Forbes
Reading time: < 15 minutes
Article

Baseplate Design for Axial Compression and Bending Using AISC Design Guide 1

Zachary Forbes
Reading time: < 15 minutes
Introducing New Biaxial Bending Provisions in AISC Design Guide 1, 3rd Edition
Baseplate
Software & Services
Structural Connections
Showing 1-10 of 34 Results