15674 Technical documents
-
C-AJ-3239
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional) (bottom side access)
English
-
C-AJ-3070
(Firestop System Details / UL Detail Drawing)
Cables (separated)
English
-
C-AJ-4017
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
C-AJ-2023
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC, CPVC, or Aquarise CPVC
English
-
C-AJ-5044
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple insulated steel and copper pipes (max. 3")
English
-
C-AJ-3070
(CAD/BIM Typicals / Auto CAD drawing file)
Cables (separated)
English
-
C-AJ-2070
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Fusiotherm and Climatherm
English
-
C-AJ-4035
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
C-AJ-5342
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)
English
-
C-AJ-0004
(Firestop System Details / UL Detail Drawing)
Max. 6" diameter blank opening (optional steel sleeve)
English
-
C-AJ-2061
(Approval document / Penetration)
Max. 2" PVC, CPVC, RNC, PEX (closed)
English
-
C-AJ-3070
(Approval document / Penetration)
Cables (separated)
English
-
C-AJ-4094
(Approval document / Penetration)
cable tray through concrete floor/wall or block wall assembly
English
-
F-A-1004
(Approval document / Penetration)
Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT
English
-
C-AJ-5343
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")
English
-
C-AJ-3232
(Approval document / Penetration)
Cable bundle (various cables) (PW Sleeve)
English
-
C-AJ-5342
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)
English
-
C-AJ-3279
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in PVC sleeve (2-1/2" concrete)
English
-
HW-S-0053
(Approval document / Joint)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
F-A-2006
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-3208
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (PVC or steel sleeve)
English
-
C-AJ-5342
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)
English
-
C-AJ-3279
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in PVC sleeve (2-1/2" concrete)
English
-
F-A-3001
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
C-AJ-3208
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (PVC or steel sleeve)
English
-
C-AJ-1016
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
C-AJ-2024
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC, CPVC, or Aquarise CPVC (knock-out sleeve)
English
-
C-AJ-5265
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)
English
-
C-AJ-4035
(Approval document / Penetration)
Cable Tray
English
-
C-AJ-2042
(Approval document / Penetration)
Max. 2" Blazemaster CPVC plastic pipe
English
-
C-AJ-5048
(Approval document / Penetration)
Max. 2" steel pipe with max. 1" glass fiber insulation
English
-
C-AJ-3210
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional)
English
-
F-A-2025
(Approval document / Penetration)
Max.6" PVC, ABS, CPVC, FRPP, max. 4" RNC or 3" Aquarise CPVC plastic pipe (metal deck)
English
-
C-AJ-1010
(Approval document / Penetration)
Max. 2" steel, cast iron, copper, steel conduit, EMT (Bottom Side Install for Floors) (AS=0" to 3-7/8")
English
-
C-AJ-5265
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)
English
-
C-AJ-5044
(Firestop System Details / UL Detail Drawing)
Multiple insulated steel and copper pipes (max. 3")
English
-
C-AJ-2054
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP plastic pipe
English
-
C-AJ-2659
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")
English
-
F-A-0040
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-4035
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
ASSET_DOC_LOC_16707969
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")
English
-
C-AJ-2065
(Firestop System Details / UL Detail Drawing)
Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)
English
-
C-AJ-2022
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, ABS, FRPP, CPVC, RNC, or 3" Aquarise CPVC
English
-
C-AJ-4093
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple cable trays through concrete floor/wall or block wall
English
-
C-AJ-5265
(Approval document / Penetration)
Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)
English
-
C-AJ-2659
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")
English
-
C-AJ-2065
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)
English
-
C-AJ-4071
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
F-A-2013
(Firestop System Details / UL Detail Drawing)
Max. 2" PEX Tubing (SDR 9)
English
-
C-AJ-3152
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve)
English
-
C-AJ-5184
(Approval document / Penetration)
Max. 6" steel or copper pipe with max. 3" thick mineral fiber insulation (AS=1/2" to 1-1/2")
English
-
C-AJ-2021
(Firestop System Details / UL Detail Drawing)
Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)
English
-
F-A-2005
(Approval document / Penetration)
Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-2056
(Approval document / Penetration)
Max. 2" PP plastic pipe
English
-
C-AJ-4017
(Approval document / Penetration)
Cable Tray
English
-
C-AJ-3236
(Firestop System Details / UL Detail Drawing)
Single Cable (4/C 750 kcmil TEK Cable)
English
-
C-AJ-3210
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3181
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3236
(CAD/BIM Typicals / Auto CAD drawing file)
Single Cable (4/C 750 kcmil TEK Cable)
English
-
F-A-2026
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP
English
-
C-AJ-5198
(Approval document / Penetration)
Max. 4" steel or copper pipe with max. 3/4" AB/PVC insulation (2-1/2" concrete) (AS=0" to 1-3/8")
English
-
C-AJ-3210
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3096
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-1011
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)
English
-
C-AJ-5289
(Firestop System Details / UL Detail Drawing)
Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)
English
-
C-AJ-2053
(Approval document / Penetration)
Max. 6" PVC, ABS, FRPP, CPVC, or XFR (optional sleeve) (oversized opening)
English
-
C-AJ-5289
(Approval document / Penetration)
Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)
English
-
C-AJ-3318
(Approval document / Penetration)
Blank or cables through Firestop Cable Transit
English
-
HI/BPF 120-31
(Approval document / Joint)
Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")
English
-
C-AJ-5289
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)
English
-
C-AJ-4093
(Firestop System Details / UL Detail Drawing)
Multiple cable trays through concrete floor/wall or block wall
English
-
HI/BPF 120-31
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")
English
-
C-AJ-2056
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP plastic pipe
English
-
C-AJ-5090
(Approval document / Penetration)
Max. 4" steel, copper pipe with max. 3/4" AB/PVC insulation (AS=1/2" to 2-1/4")
English
-
C-AJ-4071
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
FW-D-1141
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")
English
-
C-AJ-2061
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC, CPVC, RNC, PEX (closed)
English
-
C-AJ-4077
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack
English
-
C-AJ-2057
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation
English
-
C-AJ-4083
(Firestop System Details / UL Detail Drawing)
Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")
English
-
C-AJ-2071
(Firestop System Details / UL Detail Drawing)
Max. 2" Fusiotherm and Climatherm
English
-
C-AJ-5295
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation
English
-
F-A-1005
(Firestop System Details / UL Detail Drawing)
Max. 24" steel, cast iron; max. 6" copper, steel conduit; and max. 4" EMT
English
-
F-A-2009
(Approval document)
Max. 2" PVC, CPVC, Aquarise CPVC, or PEX
English
-
C-AJ-2054
(Approval document / Penetration)
Max. 2" PP plastic pipe
English
-
C-AJ-2659
(Approval document / Penetration)
Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")
English
-
C-AJ-5295
(Firestop System Details / UL Detail Drawing)
Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation
English
-
C-AJ-1010
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, copper, steel conduit, EMT (Bottom Side Install for Floors) (AS=0" to 3-7/8")
English
-
C-AJ-3284
(Approval document / Penetration)
Blank or cables (various cables) through CP 653 Speed Sleeve
English
-
C-AJ-3216
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve)
English
-
HW-S-0053
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
F-A-2025
(CAD/BIM Typicals / Auto CAD drawing file)
Max.6" PVC, ABS, CPVC, FRPP, max. 4" RNC or 3" Aquarise CPVC plastic pipe (metal deck)
English
-
C-AJ-3232
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (PW Sleeve)
English
-
C-AJ-3216
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve)
English
-
C-AJ-3232
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (PW Sleeve)
English
-
C-AJ-0004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" diameter blank opening (optional steel sleeve)
English
-
C-AJ-5301
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")
English
-
C-AJ-2055
(Approval document)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation
English
-
F-A-0040
(Approval document / Penetration)
English
-
F-A-2006
(Approval document)
Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-3281
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve (access both sides)
English
-
C-AJ-2072
(Firestop System Details / UL Detail Drawing)
Max. 1" PEX (includes hollow core)
English
-
C-AJ-5301
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")
English
-
F-A-1004
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT
English
-
C-AJ-4077
(Firestop System Details / UL Detail Drawing)
Cable Rack
English
-
C-AJ-2061
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC, CPVC, RNC, PEX (closed)
English
-
C-AJ-2042
(Firestop System Details / UL Detail Drawing)
Max. 2" Blazemaster CPVC plastic pipe
English
-
C-AJ-4083
(CAD/BIM Typicals / Auto CAD drawing file)
Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")
English
-
C-AJ-2049
(Firestop System Details / UL Detail Drawing)
Nom. 2", 3", or 4" PVDF plastic pipe
English
-
C-AJ-4054
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
C-AJ-2055
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation
English
-
C-AJ-4094
(Firestop System Details / UL Detail Drawing)
Cable tray through concrete floor/wall or block wall assembly
English
-
C-AJ-5277
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete
English
-
C-AJ-0004
(Approval document)
Max. 6" diameter blank opening (optional steel sleeve)
English
-
HW-D-0155
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
C-AJ-2049
(Approval document)
Nom. 2", 3", or 4" PVDF plastic pipe
English
-
C-AJ-5277
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete
English
-
C-AJ-1012
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron; 6" copper, steel conduit; or 4" EMT (optional steel sleeve)
English
-
FW-D-1141
(Approval document / Joint)
Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")
English
-
C-AJ-3209
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeve w/ welded flange)
English
-
F-A-2034
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" XFR-PVC (bottom side access)
English
-
C-AJ-3239
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional) (bottom side access)
English
-
F-A-1193
(Approval document / Penetration)
English
-
C-AJ-4077
(Approval document / Penetration)
Cable Rack
English
-
C-AJ-4093
(Approval document / Penetration)
Multiple cable trays through concrete floor/wall or block wall
English
-
C-AJ-3236
(Approval document / Penetration)
Single Cable (4/C 750 kcmil TEK Cable)
English
-
C-AJ-3209
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve w/ welded flange)
English
-
F-A-2009
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC, CPVC, Aquarise CPVC, or PEX
English
-
C-AJ-3239
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional) (bottom side access)
English
-
C-AJ-5341
(Firestop System Details / UL Detail Drawing)
Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)
English
-
F-A-1193
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-2057
(Approval document)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation
English
-
F-A-2026
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP
English
-
C-AJ-6006
(Approval document / Penetration)
Electrical busway (23" x 4-1/2") (2-1/2" concrete)
English
-
C-AJ-4054
(Approval document / Penetration)
Cable Tray
English
-
C-AJ-5341
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)
English
-
C-AJ-4054
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
C-AJ-2066
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 50mm Fusiotherm SDR11 PP (closed)
English
-
C-AJ-2660
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")
English
-
HW-D-0955
(Firestop System Details / UL Detail Drawing)
Gypsum Shaft Wall to Flat Concrete Floor (includes Hollow-Core) with CFS-TTS Top Track Seal (Max. JW=19mm)
English
-
C-AJ-4094
(CAD/BIM Typicals / Auto CAD drawing file)
Cable tray through concrete floor/wall or block wall assembly
English
-
C-AJ-1011
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)
English
-
C-AJ-2053
(Firestop System Details / UL Detail Drawing)
Max. 6" PVC, ABS, FRPP, CPVC or XFR (optional sleeve) (oversized opening)
English
-
C-AJ-4034
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
C-AJ-2660
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")
English
-
C-AJ-2053
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" PVC, ABS, FRPP, CPVC or XFR (optional sleeve) (oversized opening)
English
-
C-AJ-5048
(Firestop System Details / UL Detail Drawing)
Max. 2" steel pipe with max. 1" glass fiber insulation
English
-
C-AJ-5230
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)
English
-
C-AJ-1011
(Approval document)
Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)
English
-
HW-D-1125
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall (with RipTRAK) to concrete over fluted metal deck or flat concrete (Max. JW=4")
English
-
C-AJ-2070
(Firestop System Details / UL Detail Drawing)
Max. 2" Fusiotherm and Climatherm
English
-
C-AJ-1023
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, 6" copper, steel conduit, or 4" EMT (sleeve optional)
English
-
C-AJ-5061
(Approval document / Penetration)
Max. 20" steel, cast iron, max. 6" copper pipe with max. 3" Glass fiber insulation (Steel sleeve optional)
English
-
F-A-2026
(Approval document)
Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP
English
-
C-AJ-3209
(Approval document / Penetration)
Cable bundle (various cables) (sleeve w/ welded flange)
English
-
C-AJ-2036
(Approval document)
Max. 4" PVC, ABS, or CPVC Plastic Pipe
English
-
C-AJ-5230
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)
English
-
C-AJ-1022
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, 6" copper, steel conduit or 4" EMT (sleeve optional)
English
-
FF-D-0155
(Approval document / Joint)
Concrete floor to floor joint
English
-
C-AJ-3198
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (PVC sleeve)
English
-
C-AJ-3281
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve (access both sides)
English
-
F-A-2005
(Firestop System Details / UL Detail Drawing)
Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-3320
(Approval document / Penetration)
Cable bundle (various cables)
English
-
C-AJ-5301
(Approval document / Penetration)
Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")
English
-
C-AJ-3198
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (PVC sleeve)
English
-
F-A-2005
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2” PVC waste/overflow fittings
English
-
C-AJ-3281
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve (access both sides)
English
-
C-AJ-3298
(Approval document / Penetration)
Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)
English
-
C-AJ-5343
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")
English
-
C-AJ-3084
(Approval document / Penetration)
Cable bundle (telephone cables) PVC sleeve
English
-
C-AJ-2057
(Firestop System Details / UL Detail Drawing)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation
English
-
C-AJ-3198
(Approval document / Penetration)
Cable bundle (various cables) (PVC sleeve)
English
-
F-A-1003
(Approval document)
Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)
English
-
C-AJ-2065
(Approval document)
Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)
English
-
C-AJ-5343
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")
English
-
C-AJ-4034
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
C-AJ-2071
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Fusiotherm and Climatherm
English
-
C-AJ-3084
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (telephone cables) PVC sleeve
English
-
C-AJ-5048
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel pipe with max. 1" glass fiber insulation
English
-
C-AJ-1012
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron; 6" copper, steel conduit; or 4" EMT (optional steel sleeve)
English
-
C-AJ-3320
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
C-AJ-5096
(Approval document / Penetration)
Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")
English
-
F-A-3001
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
C-AJ-3084
(Firestop System Details / UL Detail Drawing)
Cable bundle (telephone cables) PVC sleeve
English
-
HW-D-0155
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
C-AJ-2042
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Blazemaster CPVC plastic pipe
English
-
C-AJ-5069
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")
English
-
C-AJ-5185
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")
English
-
C-AJ-1016
(Approval document)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
C-AJ-3193
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-5230
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)
English
-
HW-S-0053
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
C-AJ-5091
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")
English
-
C-AJ-3095
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional) (2-1/2" Concrete)
English
-
C-AJ-2056
(Firestop System Details / UL Detail Drawing)
Max. 2" PP plastic pipe
English
-
C-AJ-1022
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, 6" copper, steel conduit or 4" EMT (sleeve optional)
English
-
C-AJ-5295
(Approval document / Penetration)
Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation
English
-
F-A-2034
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" XFR-PVC (bottom side access)
English
-
C-AJ-2024
(Approval document)
Max. 2" PVC, CPVC, or Aquarise CPVC (knock-out sleeve)
English
-
C-AJ-5185
(Firestop System Details / UL Detail Drawing)
Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")
English
-
C-AJ-2021
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)
English
-
C-AJ-3181
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3283
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve (top side access)
English
-
WW-D-0270
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Optional one side installation) (Max. JW=2")
English
-
C-AJ-3208
(Approval document / Penetration)
Cable bundle (various cables) (PVC or steel sleeve)
English
-
C-AJ-3181
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional)
English
-
F-A-1004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT
English
-
C-AJ-3283
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve (top side access)
English
-
C-AJ-5069
(Approval document / Penetration)
Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")
English
-
C-AJ-2660
(Approval document / Penetration)
Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")
English
-
C-AJ-6017
(Firestop System Details / UL Detail Drawing)
Electrical busway (26" x 6")
English
-
C-AJ-3285
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve (top side access)
English
-
HW-D-0930
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")
English
-
F-A-0001
(Approval document)
Max. 10" dia blank opening
English
-
C-AJ-2070
(Approval document)
Max. 2" Fusiotherm and Climatherm
English
-
F-A-2009
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC, CPVC, Aquarise CPVC, or PEX
English
-
C-AJ-6017
(CAD/BIM Typicals / Auto CAD drawing file)
Electrical busway (26" x 6")
English
-
C-AJ-3320
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
C-AJ-3096
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3319
(Approval document / Penetration)
Cables (various) through Firestop Cable Transit
English
-
C-AJ-5069
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")
English
-
C-AJ-3318
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Firestop Cable Transit
English
-
C-AJ-3096
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional)
English
-
HW-D-0930
(Approval document / Joint)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")
English
-
FF-D-1216
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint with CFS-SP SIL Firestop Silicone Joint Spray (Max. JW=3")
English
-
C-AJ-2035
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" PVC, ABS, FRPP, or CPVC,max 4" RNC or 3" Aquarise CPVC
English
-
C-AJ-5091
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")
English
-
C-AJ-1023
(Approval document)
Max. 30" steel, cast iron, 6" copper, steel conduit, or 4" EMT (sleeve optional)
English
-
C-AJ-1016
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
C-AJ-2055
(Firestop System Details / UL Detail Drawing)
Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation
English
-
F-A-0001
(Firestop System Details / UL Detail Drawing)
Max. 10" dia blank opening
English
-
C-AJ-2022
(Approval document)
Max. 4" PVC, ABS, FRPP, CPVC, RNC, or 3" Aquarise CPVC
English
-
C-AJ-4071
(Approval document / Penetration)
Cable Tray
English
-
F-A-1002
(Firestop System Details / UL Detail Drawing)
Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)
English
-
C-AJ-2023
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC, CPVC, or Aquarise CPVC
English
-
WW-D-0270
(Approval document / Joint)
Concrete wall to wall joint (Optional one side installation) (Max. JW=2")
English
-
C-AJ-3152
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve)
English
-
C-AJ-3285
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve (top side access)
English
-
C-AJ-6017
(Approval document / Penetration)
Electrical busway (26" x 6")
English
-
C-AJ-5091
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")
English
-
C-AJ-3152
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve)
English
-
F-A-1002
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)
English
-
C-AJ-3285
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve (top side access)
English
-
C-AJ-2072
(Approval document)
Max. 1" PEX (includes hollow core)
English
-
C-AJ-4083
(Approval document / Penetration)
Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")
English
-
W-L-2027
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" PVC or CPVC
English
-
C-AJ-1184
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")
English
-
F-A-5005
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber
English
-
C-AJ-1342
(Approval document / Penetration)
Max. 8" aluminum tubing (AS=1/2" to 1-1/2")
English
-
W-L-2056
(Firestop System Details / UL Detail Drawing)
Max. 2" PP, Fusiotherm or Climatherm
English
-
C-AJ-1388
(Approval document / Penetration)
Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)
English
-
W-J-2028
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
W-L-2044
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (sch 80)
English
-
C-AJ-1453
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")
English
-
C-AJ-1291
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")
English
-
C-AJ-1453
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")
English
-
C-AJ-1453
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")
English
-
C-AJ-0058
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" blank opening (no sleeve)
English
-
W-J-2011
(Approval document / Penetration)
Max/ 1-1/2" PVC or 1" PEX
English
-
C-AJ-1184
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")
English
-
C-AJ-0055
(Approval document / Penetration)
Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)
English
-
C-AJ-0086
(Approval document / Penetration)
Max. 6" un-sleeved blank opening
English
-
C-AJ-1498
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")
English
-
C-AJ-0058
(Firestop System Details / UL Detail Drawing)
Max. 4" blank opening (no sleeve)
English
-
C-AJ-1498
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")
English
-
C-AJ-1277
(Approval document / Penetration)
Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")
English
-
C-AJ-1498
(Approval document / Penetration)
Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")
English
-
W-J-2016
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)
English
-
F-C-2007
(Firestop System Details / UL Detail Drawing)
Max 4” PVC, CPVC, or 4" Aquarise CPVC Plastic Pipe
English
-
W-L-2038
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more)
English
-
W-L-2050
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
C-AJ-1156
(Firestop System Details / UL Detail Drawing)
Max. 21" steel pipe (AS=0" to 3")
English
-
C-AJ-1575
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)
English
-
W-L-2038
(Approval document / Penetration)
Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more))
English
-
F-A-3002
(Approval document / Penetration)
Cable bundle (various cables)
English
-
C-AJ-1156
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" steel pipe (AS=0" to 3")
English
-
W-L-2031
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC
English
-
W-L-2019
(CAD/BIM Typicals / Auto CAD drawing file)
Max/ 1-1/2" PVC or 1" PEX
English
-
C-AJ-1276
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, conduit, or EMT pipe (AS=3/4")
English
-
F-B-2006
(Approval document / Penetration)
Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc
English
-
C-AJ-1226
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")
English
-
W-L-2047
(Approval document / Penetration)
Max 1" PEX (SDR 9) (max qty = 6) (closed)
English
-
C-AJ-1276
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, conduit, or EMT pipe (AS=3/4")
English
-
F-C-2005
(Firestop System Details / UL Detail Drawing)
Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe
English
-
W-L-8001
(Firestop System Details / UL Detail Drawing)
Multiple HVAC Line Sets
English
-
C-AJ-1435
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
C-AJ-1435
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
C-AJ-0074
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)
English
-
F-E-2005
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" PEX or Aquarise CPVC
English
-
C-AJ-1517
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")
English
-
C-AJ-0074
(Firestop System Details / UL Detail Drawing)
Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)
English
-
C-AJ-1517
(Firestop System Details / UL Detail Drawing)
Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")
English
-
F-A-5004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel or cast iron with 1-1/2" glass fiber
English
-
C-AJ-1154
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")
English
-
F-B-2009
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC transitioning to steel
English
-
W-L-2031
(Approval document / Penetration)
Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC
English
-
F-A-8002
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening
English
-
C-AJ-1154
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")
English
-
W-J-2012
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC
English
-
W-J-2016
(Approval document / Penetration)
Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)
English
-
W-L-2038
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more)
English
-
C-AJ-1149
(Approval document / Penetration)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")
English
-
C-AJ-1610
(Approval document / Penetration)
Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")
English
-
W-L-0003
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" blank steel sleeve
English
-
C-AJ-1609
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")
English
-
C-AJ-1278
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")
English
-
F-C-2005
(Approval document / Penetration)
Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe
English
-
W-L-2056
(Approval document / Penetration)
Max. 2" PP, Fusiotherm or Climatherm
English
-
C-AJ-1278
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")
English
-
W-L-7007
(Firestop System Details / UL Detail Drawing)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-1421
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")
English
-
F-C-2009
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" PVC or ABS bathtub fittings
English
-
W-J-2246
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (sch 80)
English
-
C-AJ-1421
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")
English
-
W-J-2012
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC
English
-
W-L-8001
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple HVAC Line Sets
English
-
C-AJ-0082
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)
English
-
C-AJ-1276
(Approval document / Penetration)
Max. 4" steel, conduit, or EMT pipe (AS=3/4")
English
-
F-C-2378
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX
English
-
C-AJ-1572
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")
English
-
W-J-2028
(Approval document / Penetration)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
C-AJ-0082
(Firestop System Details / UL Detail Drawing)
Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)
English
-
C-AJ-1572
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")
English
-
C-AJ-1572
(Approval document / Penetration)
Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")
English
-
C-AJ-1149
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")
English
-
C-AJ-1454
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)
English
-
W-L-2027
(Approval document / Penetration)
Max. 12" PVC or CPVC
English
-
F-B-2009
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" PVC transitioning to steel
English
-
C-AJ-1149
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")
English
-
W-L-0003
(Firestop System Details / UL Detail Drawing)
Max. 4" blank steel sleeve
English
-
W-L-2044
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (sch 80)
English
-
W-J-7001
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-1326
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")
English
-
F-C-2007
(Approval document / Penetration)
Max 4” PVC, CPVC, or 4" Aquarise CPVC Plastic Pipe
English
-
W-L-7007
(Approval document / Penetration)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-0082
(Approval document / Penetration)
Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)
English
-
C-AJ-1326
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")
English
-
C-AJ-1449
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")
English
-
C-AJ-1326
(Approval document / Penetration)
Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")
English
-
C-AJ-1382
(Firestop System Details / UL Detail Drawing)
Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")
English
-
C-AJ-2218
(Approval document / Penetration)
Max. 3" PVC or CPVC (closed or open)
English
-
C-AJ-1382
(Approval document / Penetration)
Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")
English
-
F-A-3074
(Approval document / Penetration)
English
-
C-AJ-1382
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")
English
-
W-J-2019
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" PVC or CPVC
English
-
F-B-2006
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc
English
-
W-L-5010
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)
English
-
F-E-2005
(Firestop System Details / UL Detail Drawing)
Max. 1" PEX or Aquarise CPVC
English
-
F-C-2010
(CAD/BIM Typicals / Auto CAD drawing file)
Nom. 4" ABS or PVC closet flange
English
-
C-AJ-1597
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" steel conduit, 4" EMT or copper (AS=0" to 2")
English
-
C-AJ-0090
(Firestop System Details / UL Detail Drawing)
Max. 6" blank opening (optional steel pipe sleeve)
English
-
C-AJ-1346
(Approval document / Penetration)
Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")
English
-
C-AJ-1610
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")
English
-
C-AJ-1421
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")
English
-
C-AJ-0138
(Firestop System Details / UL Detail Drawing)
Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block
English
-
C-AJ-0058
(Approval document / Penetration)
Max. 4" blank opening (no sleeve)
English
-
W-L-2019
(Approval document / Penetration)
Max/ 1-1/2" PVC or 1" PEX
English
-
C-AJ-1610
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")
English
-
F-C-2006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe
English
-
C-AJ-1278
(Approval document / Penetration)
Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")
English
-
C-AJ-0138
(CAD/BIM Typicals / Auto CAD drawing file)
Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block
English
-
W-L-2047
(CAD/BIM Typicals / Auto CAD drawing file)
Max 1" PEX (SDR 9) (max qty = 6) (closed)
English
-
W-L-2019
(Firestop System Details / UL Detail Drawing)
Max/ 1-1/2" PVC or 1" PEX
English
-
W-J-2246
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (sch 80)
English
-
C-AJ-1346
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")
English
-
F-C-2010
(Approval document)
Nom. 4" ABS or PVC closet flange
English
-
C-AJ-1346
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")
English
-
F-E-2006
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, ABS, CPVC, or Aquarise CPVC Plastic Pipe
English
-
C-AJ-1372
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")
English
-
C-AJ-1513
(Approval document / Penetration)
Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")
English
-
F-C-2011
(Approval document)
Max 4" PVC, ABS, CPVC, Aquarise CPVC or XFR-PVC Plastic Pipe
English
-
C-AJ-1372
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")
English
-
W-J-2245
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
C-AJ-0105
(Approval document / Penetration)
Max. 24" x 24" opening
English
-
W-L-2050
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
W-L-2031
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC
English
-
C-AJ-0105
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 24" opening
English
-
F-C-2007
(CAD/BIM Typicals / Auto CAD drawing file)
Max 4” PVC, CPVC, or 3" Aquarise CPVC Plastic Pipe
English
-
C-AJ-1609
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")
English
-
W-L-2018
(Approval document)
Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC
English
-
C-AJ-0105
(Firestop System Details / UL Detail Drawing)
Max. 24" x 24" opening
English
-
C-AJ-1609
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")
English
-
C-AJ-1184
(Approval document / Penetration)
Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")
English
-
C-AJ-1606
(Firestop System Details / UL Detail Drawing)
One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")
English
-
C-AJ-0097
(Firestop System Details / UL Detail Drawing)
Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)
English
-
C-AJ-1140
(Approval document / Penetration)
Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)
English
-
W-L-0003
(Approval document)
Max. 4" blank steel sleeve
English
-
C-AJ-1606
(CAD/BIM Typicals / Auto CAD drawing file)
One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")
English
-
C-AJ-0097
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)
English
-
W-J-2247
(Approval document / Penetration)
Nom. 2" PP (sch 80)
English
-
W-L-2056
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP, Fusiotherm or Climatherm
English
-
F-C-2378
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX
English
-
W-L-2043
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
W-J-2028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
C-AJ-1380
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")
English
-
F-C-2378
(Approval document)
Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX
English
-
C-AJ-1380
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")
English
-
C-AJ-1342
(Firestop System Details / UL Detail Drawing)
Max. 8" aluminum tubing (AS=1/2" to 1-1/2")
English
-
W-L-8001
(Approval document)
Multiple HVAC Line Sets
English
-
F-C-2009
(Approval document)
Max. 1-1/2" PVC or ABS bathtub fittings
English
-
C-AJ-1342
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" aluminum tubing (AS=1/2" to 1-1/2")
English
-
F-A-5005
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber
English
-
W-J-2247
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (sch 80)
English
-
W-L-2047
(Firestop System Details / UL Detail Drawing)
Max 1" PEX (SDR 9) (max qty = 6) (closed)
English
-
W-L-2045
(CAD/BIM Typicals / Auto CAD drawing file)
Nom. 2" PP (sch 80)
English
-
C-AJ-1140
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)
English
-
F-C-2005
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe
English
-
W-L-2020
(Approval document)
Max. 2" PVC
English
-
C-AJ-1606
(Approval document / Penetration)
One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")
English
-
C-AJ-1154
(Approval document / Penetration)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")
English
-
C-AJ-1140
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)
English
-
C-AJ-1575
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)
English
-
C-AJ-0086
(Firestop System Details / UL Detail Drawing)
Max. 6" un-sleeved blank opening
English
-
W-J-7001
(Approval document)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-1575
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)
English
-
F-C-2011
(CAD/BIM Typicals / Auto CAD drawing file)
Max 4" PVC, ABS, CPVC, Aquarise CPVC or XFR-PVC Plastic Pipe
English
-
C-AJ-0086
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" un-sleeved blank opening
English
-
W-L-7007
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-1156
(Approval document / Penetration)
Max. 20" steel pipe (AS=0" to 3")
English
-
W-J-2016
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)
English
-
C-AJ-1388
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)
English
-
F-E-2005
(Approval document)
Max. 1" PEX or Aquarise CPVC
English
-
W-J-2245
(Firestop System Details / UL Detail Drawing)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
F-A-5004
(Firestop System Details / UL Detail Drawing)
Max. 6" steel or cast iron with 1-1/2" glass fiber
English
-
C-AJ-1388
(Firestop System Details / UL Detail Drawing)
Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)
English
-
C-AJ-2218
(Firestop System Details / UL Detail Drawing)
Max. 3" PVC or CPVC (closed or open)
English
-
C-AJ-1291
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")
English
-
C-AJ-1534
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")
English
-
W-L-5010
(Approval document)
Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)
English
-
C-AJ-2218
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" PVC or CPVC (closed or open)
English
-
F-C-2006
(Approval document)
Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe
English
-
C-AJ-1291
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")
English
-
W-L-2043
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
W-L-2045
(Firestop System Details / UL Detail Drawing)
Nom. 2" PP (sch 80)
English
-
F-B-2006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc
English
-
W-L-2028
(Approval document)
Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC
English
-
C-AJ-1150
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, conduit or max. 4" EMT pipe (AS=0" to 1-3/8")
English
-
W-J-2246
(Approval document / Penetration)
Max. 2" PP (sch 80)
English
-
F-A-3002
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
C-AJ-0081
(Approval document / Penetration)
Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)
English
-
C-AJ-1534
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")
English
-
C-AJ-0081
(Firestop System Details / UL Detail Drawing)
Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)
English
-
C-AJ-1435
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
W-J-2019
(Approval document)
Max. 12" PVC or CPVC
English
-
C-AJ-1534
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")
English
-
F-A-3074
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-0081
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)
English
-
W-J-2011
(CAD/BIM Typicals / Auto CAD drawing file)
Max/ 1-1/2" PVC or 1" PEX
English
-
C-AJ-1380
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")
English
-
C-AJ-1425
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
C-AJ-1425
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
W-L-2028
(Firestop System Details / UL Detail Drawing)
Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC
English
-
C-AJ-1372
(Approval document / Penetration)
Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")
English
-
C-AJ-1277
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")
English
-
W-L-2050
(Approval document)
Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)
English
-
F-B-2009
(Approval document)
Max. 4" PVC transitioning to steel
English
-
C-AJ-1277
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")
English
-
C-AJ-1425
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")
English
-
W-L-2018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC
English
-
W-L-2032
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 6" PVC
English
-
C-AJ-1155
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")
English
-
F-A-3001
(Approval document)
Cable bundle (various cables)
English
-
W-L-2032
(Approval document)
Nominal 6" PVC
English
-
C-AJ-0074
(Approval document / Penetration)
Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)
English
-
C-AJ-1155
(Firestop System Details / UL Detail Drawing)
Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")
English
-
F-A-5005
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber
English
-
W-L-2020
(Firestop System Details / UL Detail Drawing)
Max. 2" PVC
English
-
F-A-3002
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
C-AJ-0097
(Approval document / Penetration)
Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)
English
-
F-C-2010
(Firestop System Details / UL Detail Drawing)
Nom. 4" ABS or PVC closet flange
English
-
C-AJ-1513
(Firestop System Details / UL Detail Drawing)
Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")
English
-
C-AJ-0070
(Firestop System Details / UL Detail Drawing)
Max. 7" un-sleeved blank opening
English
-
W-J-2012
(Approval document)
Max. 2" PVC
English
-
C-AJ-1513
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")
English
-
F-E-2006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" PVC, ABS, CPVC, or Aquarise CPVC Plastic Pipe
English
-
C-AJ-1517
(Approval document / Penetration)
Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")
English
-
C-AJ-1449
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")
English
-
C-AJ-0138
(Approval document / Penetration)
Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block
English
-
W-J-2245
(Approval document / Penetration)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
C-AJ-1449
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")
English
-
W-L-5010
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)
English
-
W-L-2032
(Firestop System Details / UL Detail Drawing)
Nominal 6" PVC
English
-
F-C-2006
(Firestop System Details / UL Detail Drawing)
Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe
English
-
W-J-7001
(Firestop System Details / UL Detail Drawing)
Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation
English
-
C-AJ-1226
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")
English
-
C-AJ-1158
(Approval document / Penetration)
Max/ 10" steel or cast iron pipe (AS=0" to 1-1/4")
English
-
W-L-2045
(Approval document)
Nom. 2" PP (sch 80)
English
-
F-A-8002
(Approval document)
Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening
English
-
C-AJ-1226
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")
English
-
W-L-2020
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC
English
-
W-L-2028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC
English
-
C-AJ-1158
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel or cast iron pipe (AS=0" to 1-1/4")
English
-
F-A-5004
(Approval document)
Max. 6" steel or cast iron with 1-1/2" glass fiber
English
-
W-L-2043
(Approval document)
Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation
English
-
C-AJ-1158
(Firestop System Details / UL Detail Drawing)
Max. 10" steel or cast iron pipe (AS=0" to 1-1/4")
English
-
W-L-2027
(Firestop System Details / UL Detail Drawing)
Max. 12" PVC or CPVC
English
-
C-AJ-1155
(Approval document / Penetration)
Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")
English
-
W-J-2011
(Firestop System Details / UL Detail Drawing)
Max/ 1-1/2" PVC or 1" PEX
English
-
W-L-2018
(Firestop System Details / UL Detail Drawing)
Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC
English
-
C-AJ-1454
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)
English
-
C-AJ-0055
(Firestop System Details / UL Detail Drawing)
Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)
English
-
C-AJ-1454
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)
English
-
C-AJ-0055
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)
English
-
C-BJ-4026
(Approval document / Penetration)
Cable Rack (Telecom)
English
-
C-AJ-8044
(Firestop System Details / UL Detail Drawing)
Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")
English
-
F-A-1192
(Approval document / Penetration)
English
-
F-A-1018
(Approval document / Penetration)
Max. 1" flexible steel conduit
English
-
C-AJ-8041
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)
English
-
C-BJ-8014
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack (Telecom)
English
-
F-A-1016
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)
English
-
C-AJ-6036
(CAD/BIM Typicals / Auto CAD drawing file)
Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")
English
-
F-A-1017
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-7006
(Firestop System Details / UL Detail Drawing)
Max. 36" grease duct manufactured by Metal-Fab (AS=1")
English
-
C-AJ-8210
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through concrete floor/wall or block wall
English
-
C-AJ-7104
(Approval document / Penetration)
Max. 24" x 12" sheet metal duct w/o damper (bottom side access)
English
-
C-BJ-8027
(Firestop System Details / UL Detail Drawing)
Single HVAC Line set (8" hollow core)
English
-
C-AJ-8177
(Approval document / Penetration)
Insulated or non-insulated metallic pipes, conduits, non-metallic pipes cables, and sheet metal duct
English
-
F-A-1023
(Approval document / Penetration)
Max. 2" and 3" Steel conduit or EMT
English
-
F-A-0005
(Firestop System Details / UL Detail Drawing)
Blank CP 680-P (2-1/2" Concrete)
English
-
C-AJ-8208
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through concrete floor/wall or block wall
English
-
C-AJ-6036
(Firestop System Details / UL Detail Drawing)
Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")
English
-
F-A-0014
(Approval document / Penetration)
Blank CP 680-M or CP 680-P
English
-
C-AJ-8210
(Approval document / Penetration)
Multiple penetrating items through concrete floor/wall or block wall
English
-
F-A-1014
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, 6" copper, conduit or 4" EMT pipe
English
-
C-AJ-7006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 36" grease duct manufactured by Metal-Fab (AS=1")
English
-
W-J-1088
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
C-AJ-8209
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through concrete floor/wall or block wall
English
-
C-BJ-8024
(CAD/BIM Typicals / Auto CAD drawing file)
One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")
English
-
C-AJ-7145
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation
English
-
C-AJ-7098
(Approval document / Penetration)
Max. 49" x 49" steel grease duct with 1-1/2" Firemaster« Fast Wrap manufactured by Thermal Ceramics
English
-
C-AJ-8058
(Firestop System Details / UL Detail Drawing)
Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)
English
-
W-J-1088
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
W-J-1042
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
C-AJ-8038
(Firestop System Details / UL Detail Drawing)
Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")
English
-
C-BJ-8010
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle
English
-
C-AJ-8056
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)
English
-
C-AJ-7084
(Approval document / Penetration)
Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)
English
-
C-BJ-8010
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle
English
-
C-AJ-8110
(Approval document / Penetration)
Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)
English
-
C-AJ-8178
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set w/ PVC drain
English
-
C-BJ-8027
(Approval document / Penetration)
Single HVAC Line set (8" hollow core)
English
-
F-A-1022
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)
English
-
C-AJ-7046
(Firestop System Details / UL Detail Drawing)
Max. 32" x 32" sheet metal duct w/o damper
English
-
C-BJ-0022
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" unsleeved opening
English
-
C-BJ-8020
(Firestop System Details / UL Detail Drawing)
Multiple bundle of metallic pipes and cables
English
-
C-AJ-8180
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)
English
-
C-AJ-8099
(Approval document / Penetration)
Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)
English
-
F-A-0012
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 12" or 12" diameter blank opening
English
-
C-AJ-7030
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated Flamebar BW11 Coated Fire Rated Ductwork
English
-
C-AJ-7029
(Approval document / Penetration)
Flamebar BW 11 Fire Rated Duct Work
English
-
C-BJ-3032
(Approval document / Penetration)
Cables (various) through Firestop Cable Transit
English
-
C-BJ-1046
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
W-J-0007
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 36" blank opening
English
-
C-AJ-7123
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")
English
-
C-BJ-1045
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-8095
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
F-A-1029
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe
English
-
C-AJ-8107
(Approval document / Penetration)
Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)
English
-
C-BJ-3024
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
C-AJ-6042
(Approval document / Penetration)
electrical busway through concrete floor/wall or block wall
English
-
C-AJ-8096
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-J-1028
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")
English
-
C-AJ-7140
(Firestop System Details / UL Detail Drawing)
Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")
English
-
C-BJ-8013
(Approval document / Penetration)
Cable Rack (Telecom)
English
-
C-AJ-8081
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel tube and cables (AS varies)
English
-
C-BJ-5018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
C-AJ-8166
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set (optional sleeve) (bottom side access)
English
-
F-A-1028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)
English
-
C-AJ-7095
(Approval document / Penetration)
Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")
English
-
C-AJ-7084
(Firestop System Details / UL Detail Drawing)
Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)
English
-
C-AJ-8081
(Approval document / Penetration)
Max. 6" steel tube and cables (AS varies)
English
-
C-BJ-1037
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete
English
-
C-BJ-7005
(Approval document / Penetration)
Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)
English
-
C-BJ-8013
(Firestop System Details / UL Detail Drawing)
Cable Rack (Telecom)
English
-
F-A-0014
(Firestop System Details / UL Detail Drawing)
Blank CP 680-M or CP 680-P
English
-
F-A-0006
(CAD/BIM Typicals / Auto CAD drawing file)
Blank CP 680-P
English
-
C-AJ-7051
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 30" sheet metal duct w/o damper
English
-
W-J-1042
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
C-BJ-1034
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, conduit or EMT pipe
English
-
C-BJ-1059
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")
English
-
W-J-0010
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" blank opening (optional sleeve)
English
-
C-AJ-8056
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)
English
-
F-A-1192
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-BJ-5015
(Approval document / Penetration)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
W-J-1058
(Approval document / Penetration)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
C-AJ-8099
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)
English
-
F-A-1014
(Approval document / Penetration)
Max. 12" steel, 6" copper, conduit or 4" EMT pipe
English
-
C-BJ-4026
(Firestop System Details / UL Detail Drawing)
Cable Rack (Telecom)
English
-
W-J-1020
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, copper, conduit or EMT pipe
English
-
C-AJ-7122
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")
English
-
F-A-1022
(Approval document / Penetration)
Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)
English
-
C-AJ-8178
(Approval document / Penetration)
HVAC line set w/ PVC drain
English
-
C-AJ-7111
(Approval document / Penetration)
Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)
English
-
C-AJ-8096
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
C-BJ-4025
(Approval document / Penetration)
Cable Rack (Telecom)
English
-
C-BJ-5013
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper with max. 1" glass fiber insulation
English
-
C-BJ-3031
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or Cables (various) through Firestop Cable Transit
English
-
C-BJ-5006
(Approval document / Penetration)
Max. 20" steel with max. 3" Glass Fiber insulation
English
-
F-A-1037
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
W-J-0007
(Firestop System Details / UL Detail Drawing)
Max. 24" x 36" blank opening
English
-
C-BJ-1046
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-BJ-7005
(Firestop System Details / UL Detail Drawing)
Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)
English
-
F-A-1017
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
F-A-1014
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, 6" copper, conduit or 4" EMT pipe
English
-
C-AJ-7122
(Approval document / Penetration)
Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")
English
-
C-AJ-8148
(Firestop System Details / UL Detail Drawing)
HVAC line set (optional sleeve)
English
-
C-AJ-7095
(CAD/BIM Typicals / Auto CAD drawing file)
Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")
English
-
W-J-1028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")
English
-
C-BJ-1045
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-2420
(Firestop System Details / UL Detail Drawing)
Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")
English
-
C-BJ-1049
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)
English
-
W-J-0022
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2-1/2" dia or 2" x 2" blank opening
English
-
C-AJ-7104
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" sheet metal duct w/o damper (bottom side access)
English
-
W-J-1020
(Approval document / Penetration)
Max. 4" steel, copper, conduit or EMT pipe
English
-
C-AJ-2420
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")
English
-
C-AJ-8209
(Approval document / Penetration)
Multiple penetrating items through concrete floor/wall or block wall
English
-
C-AJ-8107
(Firestop System Details / UL Detail Drawing)
Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)
English
-
F-A-1018
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit
English
-
C-BJ-5013
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper with max. 1" glass fiber insulation
English
-
W-J-0015
(Firestop System Details / UL Detail Drawing)
Max. area of opening - 240 sq. in. with max. dimension of 20"
English
-
C-AJ-7111
(Firestop System Details / UL Detail Drawing)
Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)
English
-
C-AJ-7103
(Approval document / Penetration)
Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)
English
-
C-AJ-8166
(Approval document / Penetration)
HVAC line set (optional sleeve) (bottom side access)
English
-
F-A-1028
(Approval document / Penetration)
Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)
English
-
C-AJ-8100
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated copper or cables (single or bundled) (AS varies)
English
-
C-BJ-4026
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack (Telecom)
English
-
C-BJ-4025
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack (Telecom)
English
-
F-A-0012
(Approval document / Penetration)
Max. 30" x 12" or 12" diameter blank opening
English
-
C-AJ-8107
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)
English
-
C-AJ-8038
(Approval document / Penetration)
Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")
English
-
W-J-1068
(Approval document / Penetration)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve
English
-
C-AJ-7104
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" sheet metal duct w/o damper (bottom side access)
English
-
W-J-0010
(Approval document / Penetration)
Max. 4" blank opening (optional sleeve)
English
-
W-J-0010
(Firestop System Details / UL Detail Drawing)
Max. 4" blank opening (optional sleeve)
English
-
C-BJ-1049
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)
English
-
C-BJ-5015
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
F-A-1037
(Approval document / Penetration)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
F-A-1017
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-8110
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)
English
-
C-AJ-7103
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)
English
-
W-J-1020
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, copper, conduit or EMT pipe
English
-
C-BJ-1047
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel or cast iron (2 hour T-rating)
English
-
C-BJ-1046
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
W-J-0007
(Approval document / Penetration)
Max. 24" x 36" blank opening
English
-
W-J-1021
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 18" steel or max. 4" copper pipe
English
-
C-AJ-7098
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 49" x 49" steel grease duct with 1-1/2" Firemaster® Fast Wrap manufactured by Thermal Ceramics
English
-
C-AJ-7051
(Approval document / Penetration)
Max. 30" x 30" sheet metal duct w/o damper
English
-
C-BJ-8024
(Approval document / Penetration)
One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")
English
-
F-A-1016
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)
English
-
C-BJ-5018
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
C-BJ-1047
(Firestop System Details / UL Detail Drawing)
Max. 8" steel or cast iron (2 hour T-rating)
English
-
W-J-0008
(Firestop System Details / UL Detail Drawing)
Max. 24" x 36" blank opening
English
-
C-AJ-7103
(Firestop System Details / UL Detail Drawing)
Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)
English
-
C-AJ-8110
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)
English
-
C-AJ-8100
(Approval document / Penetration)
Insulated or non-insulated copper or cables (single or bundled) (AS varies)
English
-
C-AJ-7006
(Approval document / Penetration)
Max. 36" grease duct manufactured by Metal-Fab (AS=1")
English
-
C-BJ-3032
(CAD/BIM Typicals / Auto CAD drawing file)
Cables (various) through Firestop Cable Transit
English
-
C-BJ-5006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" steel with max. 3" Glass Fiber insulation
English
-
C-AJ-8099
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)
English
-
C-BJ-1055
(Approval document / Penetration)
Max. 2" steel or cast iron
English
-
C-BJ-8014
(Approval document / Penetration)
Cable Rack (Telecom)
English
-
C-BJ-1047
(Approval document / Penetration)
Max. 8" steel or cast iron (2 hour T-rating)
English
-
C-BJ-3031
(Approval document / Penetration)
Blank or Cables (various) through Firestop Cable Transit
English
-
W-J-0022
(Firestop System Details / UL Detail Drawing)
Max. 2-1/2" dia or 2" x 2" blank opening
English
-
C-BJ-1037
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete
English
-
C-BJ-1059
(Firestop System Details / UL Detail Drawing)
Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")
English
-
C-BJ-5006
(Firestop System Details / UL Detail Drawing)
Max. 20" steel with max. 3" Glass Fiber insulation
English
-
F-A-1022
(Firestop System Details / UL Detail Drawing)
Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)
English
-
C-AJ-8100
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated copper or cables (single or bundled) (AS varies)
English
-
C-AJ-6036
(Approval document / Penetration)
Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")
English
-
C-AJ-8095
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-7111
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)
English
-
W-J-0015
(CAD/BIM Typicals / Auto CAD drawing file)
Max. area of opening - 240 sq. in. with max. dimension of 20"
English
-
C-BJ-1055
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel or cast iron
English
-
C-BJ-1037
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete
English
-
W-J-1041
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
C-AJ-2420
(Approval document / Penetration)
Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")
English
-
C-AJ-7084
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)
English
-
F-A-0005
(CAD/BIM Typicals / Auto CAD drawing file)
Blank CP 680-P (2-1/2" Concrete)
English
-
C-BJ-0022
(Approval document / Penetration)
Max. 24" x 12" unsleeved opening
English
-
C-AJ-8166
(Firestop System Details / UL Detail Drawing)
HVAC line set (optional sleeve) (bottom side access)
English
-
C-AJ-7030
(Approval document / Penetration)
Insulated Flamebar BW11 Coated Fire Rated Ductwork
English
-
C-BJ-8010
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle
English
-
C-BJ-1045
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-8058
(Approval document / Penetration)
Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)
English
-
W-J-0006
(Firestop System Details / UL Detail Drawing)
Max. 30" x 15" blank opening
English
-
C-AJ-7095
(Firestop System Details / UL Detail Drawing)
Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")
English
-
C-BJ-5018
(Approval document / Penetration)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
F-A-1029
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe
English
-
C-AJ-8148
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set (optional sleeve)
English
-
C-BJ-3024
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
C-BJ-5015
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)
English
-
C-AJ-8095
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe
English
-
C-AJ-7123
(Firestop System Details / UL Detail Drawing)
Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")
English
-
C-AJ-8044
(Approval document / Penetration)
Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")
English
-
W-J-1021
(Firestop System Details / UL Detail Drawing)
Max. 18" steel or max. 4" copper pipe
English
-
F-A-0006
(Approval document / Penetration)
Blank CP 680-P
English
-
C-BJ-3024
(Approval document / Penetration)
Cable bundle (various cables)
English
-
C-BJ-5013
(Approval document / Penetration)
Max. 4" steel or copper with max. 1" glass fiber insulation
English
-
W-J-1042
(Approval document / Penetration)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
C-BJ-4025
(Firestop System Details / UL Detail Drawing)
Cable Rack (Telecom)
English
-
F-A-1028
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)
English
-
C-AJ-8096
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
C-AJ-7122
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")
English
-
W-J-0008
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 36" blank opening
English
-
C-AJ-8180
(Approval document / Penetration)
Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)
English
-
C-BJ-0022
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" unsleeved opening
English
-
W-J-1058
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
C-AJ-7046
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 32" x 32" sheet metal duct w/o damper
English
-
W-J-1028
(Approval document / Penetration)
Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")
English
-
C-AJ-8178
(Firestop System Details / UL Detail Drawing)
HVAC line set w/ PVC drain
English
-
F-A-0012
(Firestop System Details / UL Detail Drawing)
Max. 30" x 12" or 12" diameter blank opening
English
-
C-BJ-8014
(Firestop System Details / UL Detail Drawing)
Cable Rack (Telecom)
English
-
C-BJ-1034
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, conduit or EMT pipe
English
-
W-J-0022
(Approval document / Penetration)
Max. 2-1/2" dia or 2" x 2" blank opening
English
-
C-AJ-7051
(Firestop System Details / UL Detail Drawing)
Max. 30" x 30" sheet metal duct w/o damper
English
-
C-AJ-8208
(Approval document / Penetration)
Multiple penetrating items through concrete floor/wall or block wall
English
-
F-A-1023
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" and 3" Steel conduit or EMT
English
-
C-AJ-7123
(Approval document / Penetration)
Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")
English
-
C-AJ-7140
(Approval document / Penetration)
Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")
English
-
C-AJ-8177
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated metallic pipes, conduits, non-metallic pipes cables, and sheet metal duct
English
-
C-BJ-7005
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)
English
-
C-AJ-8058
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)
English
-
C-AJ-7145
(Firestop System Details / UL Detail Drawing)
Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation
English
-
W-J-1041
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
W-J-1021
(Approval document / Penetration)
Max. 18" steel or max. 4" copper pipe
English
-
F-A-1037
(Firestop System Details / UL Detail Drawing)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
C-AJ-7145
(Approval document / Penetration)
Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation
English
-
C-AJ-8081
(Firestop System Details / UL Detail Drawing)
Max. 6" steel tube and cables (AS varies)
English
-
W-J-0015
(Approval document / Penetration)
Max. area of opening - 240 sq. in. with max. dimension of 20"
English
-
C-AJ-7140
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")
English
-
W-J-0006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 15" blank opening
English
-
C-BJ-8027
(CAD/BIM Typicals / Auto CAD drawing file)
Single HVAC Line set (8" hollow core)
English
-
C-AJ-8148
(Approval document / Penetration)
HVAC line set (optional sleeve)
English
-
F-A-1029
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe
English
-
C-AJ-8210
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through concrete floor/wall or block wall
English
-
W-J-1068
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve
English
-
C-AJ-7029
(CAD/BIM Typicals / Auto CAD drawing file)
Flamebar BW 11 Fire Rated Duct Work
English
-
F-A-0014
(CAD/BIM Typicals / Auto CAD drawing file)
Blank CP 680-M or CP 680-P
English
-
W-J-1041
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
C-AJ-8041
(Approval document / Penetration)
Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)
English
-
C-BJ-8024
(Firestop System Details / UL Detail Drawing)
One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")
English
-
W-J-1088
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
W-J-0008
(Approval document / Penetration)
Max. 24" x 36" blank opening
English
-
C-AJ-7029
(Firestop System Details / UL Detail Drawing)
Flamebar BW 11 Fire Rated Duct Work
English
-
F-A-1018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit
English
-
C-AJ-8180
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)
English
-
C-BJ-8013
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack (Telecom)
English
-
F-A-0005
(Approval document / Penetration)
Blank CP 680-P (2-1/2" Concrete)
English
-
C-AJ-8044
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")
English
-
C-AJ-8041
(Firestop System Details / UL Detail Drawing)
Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)
English
-
W-J-0006
(Approval document / Penetration)
Max. 30" x 15" blank opening
English
-
W-J-1058
(Firestop System Details / UL Detail Drawing)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
C-AJ-7046
(Approval document / Penetration)
Max. 32" x 32" sheet metal duct w/o damper
English
-
W-J-1068
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve
English
-
C-BJ-1059
(Approval document / Penetration)
Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")
English
-
C-AJ-8056
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)
English
-
C-BJ-8020
(Approval document / Penetration)
Multiple bundle of metallic pipes and cables
English
-
C-AJ-8038
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")
English
-
C-BJ-8020
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple bundle of metallic pipes and cables
English
-
C-AJ-8208
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through concrete floor/wall or block wall
English
-
C-AJ-6042
(CAD/BIM Typicals / Auto CAD drawing file)
Electrical busway through concrete floor/wall or block wall
English
-
F-A-1016
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)
English
-
C-AJ-6042
(Firestop System Details / UL Detail Drawing)
Electrical busway through concrete floor/wall or block wall
English
-
C-BJ-1034
(Approval document / Penetration)
Max. 4" steel, conduit or EMT pipe
English
-
C-BJ-1049
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)
English
-
C-AJ-8209
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through concrete floor/wall or block wall
English
-
F-A-1066
(Firestop System Details / UL Detail Drawing)
Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)
English
-
F-A-5009
(Approval document / Penetration)
Max. 10" steel pipe with 2" glass fiber insulation
English
-
F-A-3022
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (PW Sleeve)
English
-
F-A-1134
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")
English
-
F-C-1106
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
F-C-1106
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
F-A-5019
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")
English
-
F-C-1147
(Approval document / Penetration)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
F-A-8004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel tube and cables
English
-
F-A-5032
(Firestop System Details / UL Detail Drawing)
Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)
English
-
F-C-1009
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")
English
-
F-C-1135
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings
English
-
F-A-5046
(Approval document / Penetration)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber
English
-
F-A-3022
(Approval document / Penetration)
Cable bundle (various cables) (PW Sleeve)
English
-
F-A-1137
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)
English
-
F-A-2156
(Approval document / Penetration)
Max. 2" PVC shower drain fitting with CP 681 75/2"N Firestop Drain Flange or CP 681 SD-FD
English
-
F-A-1038
(Firestop System Details / UL Detail Drawing)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
F-B-4006
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" x 2" cable rack
English
-
F-A-1091
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper
English
-
F-A-1105
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT
English
-
F-A-3012
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)
English
-
F-A-1127
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)
English
-
F-A-5036
(Approval document / Penetration)
Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)
English
-
F-C-3094
(Firestop System Details / UL Detail Drawing)
Multiple SER cables in slotted opening
English
-
F-C-1009
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")
English
-
F-A-5017
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)
English
-
F-B-5003
(Approval document / Penetration)
Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")
English
-
F-A-1127
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)
English
-
F-A-8027
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)
English
-
F-A-1134
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")
English
-
F-A-5021
(Approval document / Penetration)
Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation
English
-
F-A-6002
(CAD/BIM Typicals / Auto CAD drawing file)
Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")
English
-
F-A-5042
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron or max. 4" copper with 1-1/2" glass fiber insulation (AS varies)
English
-
F-C-1147
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
F-A-5019
(Approval document / Penetration)
Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")
English
-
F-B-4006
(Approval document / Penetration)
Max. 20" x 2" cable rack
English
-
F-B-1026
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-5009
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel pipe with 2" glass fiber insulation
English
-
F-B-5004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation
English
-
F-A-1108
(Firestop System Details / UL Detail Drawing)
Max. 3" steel or cast iron with closet flange (AS=min 3/8")
English
-
F-C-3044
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (AS=3/4")
English
-
F-A-1194
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-5032
(Approval document / Penetration)
Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)
English
-
F-A-1108
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" steel or cast iron with closet flange (AS=min 3/8")
English
-
F-A-1105
(Approval document / Penetration)
Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT
English
-
F-C-3071
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-B-5005
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber
English
-
F-A-5015
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)
English
-
F-A-3019
(Approval document / Penetration)
Cable bundle (various cables) (Unique Sleeve)
English
-
F-B-1010
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)
English
-
F-C-1147
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
F-A-1066
(Approval document / Penetration)
Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)
English
-
F-C-0002
(Approval document / Penetration)
Max. 2" dia blank opening
English
-
F-A-6002
(Firestop System Details / UL Detail Drawing)
Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")
English
-
F-B-1009
(Firestop System Details / UL Detail Drawing)
Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)
English
-
F-A-5016
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation
English
-
F-C-1059
(Approval document / Penetration)
Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit
English
-
F-C-0002
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" dia blank opening
English
-
F-A-1127
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)
English
-
F-C-3074
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-A-3012
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)
English
-
F-C-1142
(Approval document / Penetration)
Max. 1" copper, steel, cast iron, steel conduit, or EMT
English
-
F-A-1105
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT
English
-
F-A-4003
(Approval document / Penetration)
Cable Tray
English
-
F-C-3012
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
F-A-5015
(Approval document / Penetration)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)
English
-
F-B-5003
(Firestop System Details / UL Detail Drawing)
Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")
English
-
F-A-4003
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
F-C-1135
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings
English
-
F-A-5032
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)
English
-
F-A-8004
(Firestop System Details / UL Detail Drawing)
Max. 6" steel tube and cables
English
-
F-A-5018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation
English
-
F-A-6002
(Approval document / Penetration)
Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")
English
-
F-C-1059
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit
English
-
F-A-1134
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")
English
-
F-A-3033
(Approval document / Penetration)
Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)
English
-
F-A-3022
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (PW Sleeve)
English
-
F-A-1066
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)
English
-
F-A-7018
(Approval document / Penetration)
Max. 6" dia sheet metal duct w/o damper
English
-
F-A-1051
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Copper, brass or cast iron waste/overflow fittings
English
-
F-A-5042
(Approval document / Penetration)
Max. 8" steel, cast iron or max. 4" copper with 1-1/2" glass fiber insulation (AS varies)
English
-
F-A-3033
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)
English
-
F-A-2156
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC shower drain (System tested to 50 Pa)
English
-
F-A-1135
(Firestop System Details / UL Detail Drawing)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)
English
-
F-C-1106
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
F-A-8012
(Approval document / Penetration)
Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening
English
-
F-A-5019
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")
English
-
F-A-8016
(Firestop System Details / UL Detail Drawing)
Multiple HVAC Line Set
English
-
F-B-5004
(Approval document / Penetration)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation
English
-
F-A-1128
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-8012
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening
English
-
F-A-8023
(Approval document / Penetration)
Multiple bundle consisting of steel pipe, ENT, cable bundle
English
-
F-A-5021
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation
English
-
F-A-5018
(Approval document / Penetration)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation
English
-
F-C-1134
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" cast iron closet flange with cast iron fittings
English
-
F-C-3012
(Approval document / Penetration)
Cable bundle (various cables)
English
-
F-A-1137
(Firestop System Details / UL Detail Drawing)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)
English
-
F-A-1119
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")
English
-
F-A-3034
(Firestop System Details / UL Detail Drawing)
Nom. 4/C No 500 kcmill TEK Cable
English
-
F-A-1038
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
F-B-4006
(Firestop System Details / UL Detail Drawing)
Max. 20" x 2" cable rack
English
-
F-A-1194
(Approval document / Penetration)
English
-
F-B-1009
(Approval document / Penetration)
Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)
English
-
F-A-1091
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper
English
-
F-A-3019
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Unique Sleeve)
English
-
F-C-3094
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple SER cables in slotted opening
English
-
F-A-1128
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-1106
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit, or EMT
English
-
F-C-1009
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")
English
-
F-A-5017
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)
English
-
F-A-8027
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)
English
-
F-A-3012
(Approval document / Penetration)
Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)
English
-
F-B-1026
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-7018
(Firestop System Details / UL Detail Drawing)
Max. 6" dia sheet metal duct w/o damper
English
-
F-A-5036
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)
English
-
F-C-1142
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper, steel, cast iron, steel conduit, or EMT
English
-
F-B-1026
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-5009
(Firestop System Details / UL Detail Drawing)
Max. 10" steel pipe with 2" glass fiber insulation
English
-
F-B-5004
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation
English
-
F-C-3044
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (AS=3/4")
English
-
F-A-1051
(Approval document / Penetration)
Max. 2" Copper, brass or cast iron waste/overflow fittings
English
-
F-A-1106
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit, or EMT
English
-
F-A-3007
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
F-C-3071
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-A-1119
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")
English
-
F-C-3071
(Approval document / Penetration)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-A-5016
(Approval document / Penetration)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation
English
-
F-A-5015
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)
English
-
F-B-1010
(Firestop System Details / UL Detail Drawing)
Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)
English
-
F-A-1137
(Approval document / Penetration)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)
English
-
F-C-1135
(Approval document / Penetration)
Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings
English
-
F-C-3094
(Approval document / Penetration)
Multiple SER cables in slotted opening
English
-
F-A-5046
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber
English
-
F-A-5046
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber
English
-
F-B-1009
(CAD/BIM Typicals / Auto CAD drawing file)
Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)
English
-
F-A-5016
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation
English
-
F-C-0002
(Firestop System Details / UL Detail Drawing)
Max. 2" dia blank opening
English
-
F-C-3074
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-A-1119
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")
English
-
F-A-3007
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
F-C-3012
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
F-A-1106
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit, or EMT
English
-
F-B-5003
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")
English
-
F-A-4003
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
F-B-1029
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit, copper or EMT
English
-
F-A-8004
(Approval document / Penetration)
Max. 6" steel tube and cables
English
-
F-C-1142
(Firestop System Details / UL Detail Drawing)
Max. 1" copper, steel, cast iron, steel conduit, or EMT
English
-
F-A-5036
(Firestop System Details / UL Detail Drawing)
Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)
English
-
F-C-3074
(Approval document / Penetration)
Cable bundle (various cables) (AS=0" to 1")
English
-
F-A-7018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" dia sheet metal duct w/o damper
English
-
F-A-1135
(Approval document / Penetration)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)
English
-
F-A-8023
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple bundle consisting of steel pipe, ENT, cable bundle
English
-
F-A-5018
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation
English
-
F-A-1038
(Approval document / Penetration)
Tub Box with max. 1-1/2" brass waste/overflow fittings
English
-
F-C-1059
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit
English
-
F-A-5017
(Approval document / Penetration)
Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)
English
-
F-C-3044
(Approval document / Penetration)
Cable bundle (various cables) (AS=3/4")
English
-
F-A-1128
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit, copper or 4" EMT
English
-
F-A-3019
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Unique Sleeve)
English
-
F-A-1091
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper
English
-
F-A-1051
(Firestop System Details / UL Detail Drawing)
Max. 2" Copper, brass or cast iron waste/overflow fittings
English
-
F-A-8027
(Approval document / Penetration)
Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)
English
-
F-A-3033
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)
English
-
F-A-1135
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)
English
-
F-A-1108
(Approval document / Penetration)
Max. 3" steel or cast iron with closet flange (AS=min 3/8")
English
-
F-C-1134
(Firestop System Details / UL Detail Drawing)
Max. 4" cast iron closet flange with cast iron fittings
English
-
F-A-5021
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation
English
-
F-A-3007
(Approval document / Penetration)
Cable bundle (various cables)
English
-
F-B-1010
(Approval document / Penetration)
Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)
English
-
F-A-8012
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening
English
-
W-J-4050
(Firestop System Details / UL Detail Drawing)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
W-J-3143
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve optional)
English
-
F-E-3012
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple SER cables in slotted opening
English
-
F-E-5013
(Approval document / Penetration)
Max. 2" steel or copper pipe with max. 1-1/2" glass fiber
English
-
W-J-1226
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, steel conduit or EMT
English
-
W-J-1095
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit
English
-
F-C-5036
(Approval document / Penetration)
Max. 2" copper, or steel pipe with max. 1-1/2" glass fiber
English
-
W-J-2229
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" PEX (bundled) (c,v) through CP 653 Speed Sleeve
English
-
W-J-5150
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
F-C-7037
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" sheet metal duct with 1-1/2" thick duct wrap
English
-
F-C-8032
(Approval document / Penetration)
Double HVAC Line Set (no pvc drain)
English
-
W-J-4060
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray (36" x 6")
English
-
W-J-5041
(Approval document / Penetration)
Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")
English
-
W-J-1221
(Firestop System Details / UL Detail Drawing)
Multiple Max. 1" Flexible steel conduits
English
-
W-J-1214
(Firestop System Details / UL Detail Drawing)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-J-3111
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through Unique Threaded Sleeve
English
-
W-J-4050
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
F-C-7043
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
F-A-3071
(Approval document / Penetration)
English
-
F-C-5065
(Firestop System Details / UL Detail Drawing)
Max. 4" copper, cast iron or steel pipe with 3/4" AB/PVC insulation
English
-
F-E-1018
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
F-C-5065
(Approval document / Penetration)
Max. 4" copper, cast iron or steel pipe with " AB/PVC insulation
English
-
W-J-1201
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
W-J-3168
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-4027
(Approval document / Penetration)
Cable Tray
English
-
W-J-1116
(Approval document / Penetration)
Max. 2" steel conduit or EMT (one or more)
English
-
W-J-3168
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-4048
(Firestop System Details / UL Detail Drawing)
Cable Rack in max. 24" x 36" opening
English
-
W-J-1221
(Approval document / Penetration)
Multiple Max. 1" Flexible steel conduits
English
-
W-J-4050
(Approval document / Penetration)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
W-J-5150
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
W-J-4060
(Firestop System Details / UL Detail Drawing)
Cable Tray (36" x 6")
English
-
W-J-3111
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through unique threaded sleeve
English
-
F-E-5004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel or copper pipe with max. 3/4" AB/PVC
English
-
W-J-1221
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple Max. 1" Flexible steel conduits
English
-
W-J-3050
(Approval document / Penetration)
Cable bundle (various cables) (sleeved)
English
-
W-J-1124
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-1123
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-5067
(Approval document / Penetration)
Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)
English
-
W-J-5140
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)
English
-
F-C-7025
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper
English
-
W-J-5003
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation
English
-
W-J-3074
(Firestop System Details / UL Detail Drawing)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
W-J-1226
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, steel conduit or EMT
English
-
W-J-1202
(Firestop System Details / UL Detail Drawing)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-J-4048
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack in max. 24" x 36" opening
English
-
F-C-7036
(Approval document / Penetration)
Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics
English
-
F-C-8044
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")
English
-
W-J-3189
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-J-4029
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
W-J-1095
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit
English
-
W-J-5140
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)
English
-
W-J-5003
(Firestop System Details / UL Detail Drawing)
Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation
English
-
W-J-3036
(Approval document / Penetration)
Cable bundle (various cables) (sleeve optional)
English
-
F-A-3071
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-7013
(Approval document / Penetration)
Max. 4" diameter sheet metal duct w/o damper (min 28Ga)
English
-
F-E-8008
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC Line Set
English
-
W-J-1214
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-J-3196
(Approval document / Penetration)
Blank or Cables (various) through Firestop Cable Transit
English
-
W-J-4059
(Approval document / Penetration)
Cable Tray
English
-
W-J-1128
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT
English
-
W-J-4029
(Approval document / Penetration)
Cable Tray
English
-
W-J-3167
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-5134
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
F-E-1018
(Approval document / Penetration)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
W-J-1193
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)
English
-
W-J-5041
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")
English
-
F-C-5066
(Approval document / Penetration)
Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber
English
-
W-J-1193
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)
English
-
W-J-3168
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-4029
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
F-C-8026
(CAD/BIM Typicals / Auto CAD drawing file)
Double HVAC Line Set (pvc drain)
English
-
W-J-3110
(Approval document / Penetration)
Cable bundle (various cables) through Unique Split Sleeve
English
-
W-J-1095
(Approval document / Penetration)
Max. 1" flexible steel conduit
English
-
F-C-7025
(Firestop System Details / UL Detail Drawing)
Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper
English
-
F-C-8032
(Firestop System Details / UL Detail Drawing)
Double HVAC Line Set (no pvc drain)
English
-
F-E-8008
(Approval document / Penetration)
HVAC Line Set
English
-
W-J-5028
(Approval document / Penetration)
Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)
English
-
F-C-8044
(Approval document / Penetration)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")
English
-
F-C-5037
(Approval document / Penetration)
Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation
English
-
W-J-3196
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or Cables (various) through Firestop Cable Transit
English
-
W-J-4016
(Firestop System Details / UL Detail Drawing)
Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")
English
-
W-J-1123
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-5134
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
W-J-5041
(Firestop System Details / UL Detail Drawing)
Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")
English
-
W-J-5140
(Approval document / Penetration)
Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)
English
-
W-J-3074
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
F-E-5004
(Approval document / Penetration)
Max. 2" steel or copper pipe with max. 3/4" AB/PVC
English
-
W-J-1202
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 4" steel, steel conduit, or EMT
English
-
F-E-3012
(Firestop System Details / UL Detail Drawing)
Multiple SER cables in slotted opening
English
-
W-J-1174
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" cast iron with "No-Hub" Connector
English
-
F-E-3012
(Approval document / Penetration)
Multiple SER cables in slotted opening
English
-
W-J-2242
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-5150
(Approval document / Penetration)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
W-J-5067
(Firestop System Details / UL Detail Drawing)
Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)
English
-
F-C-5065
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" copper, cast iron or steel pipe with 3/4" AB/PVC insulation
English
-
W-J-5057
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel pipe with max. 3" thick glass-fiber insulation
English
-
W-J-3036
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeve optional)
English
-
W-J-1175
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
W-J-3189
(Firestop System Details / UL Detail Drawing)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-J-4016
(CAD/BIM Typicals / Auto CAD drawing file)
Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")
English
-
F-C-8038
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")
English
-
F-C-5004
(Approval document / Penetration)
Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)
English
-
F-C-8026
(Approval document / Penetration)
Double HVAC Line Set (pvc drain)
English
-
W-J-5042
(Approval document / Penetration)
Max. 12" steel or 6" copper with 2" glass-fiber insulation
English
-
F-C-7042
(Firestop System Details / UL Detail Drawing)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-J-3092
(Approval document / Penetration)
Cable bundle (various cables) (PVC Sleeve)
English
-
F-E-1018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
-
W-J-3198
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Firestop Retrofit Sleeve Kit
English
-
W-J-3199
(Firestop System Details / UL Detail Drawing)
Blank or cables through Firestop Sleeve Kit
English
-
W-J-1128
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT
English
-
W-J-5067
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)
English
-
F-C-5004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)
English
-
W-J-1202
(Approval document / Penetration)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-J-5057
(Firestop System Details / UL Detail Drawing)
Max. 10" steel pipe with max. 3" thick glass-fiber insulation
English
-
W-J-3060
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeved) (AS=0" to 1")
English
-
W-J-3188
(Approval document / Penetration)
Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")
English
-
W-J-4016
(Approval document / Penetration)
Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")
English
-
W-J-1193
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)
English
-
W-J-1215
(Approval document / Penetration)
Max. 3" steel, cast iron, steel conduit or EMT
English
-
F-E-7008
(Firestop System Details / UL Detail Drawing)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
F-E-5004
(Firestop System Details / UL Detail Drawing)
Max. 2" steel or copper pipe with max. 3/4" AB/PVC
English
-
W-J-1191
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 2" steel, steel conduits, or EMT
English
-
W-J-3050
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeved)
English
-
W-J-3060
(Approval document / Penetration)
Cable bundle (various cables) (sleeved) (AS=0" to 1")
English
-
W-J-5058
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation
English
-
F-C-5036
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" copper, or steel pipe with max. 1-1/2" glass fiber
English
-
W-J-5066
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)
English
-
W-J-2241
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-1123
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-1168
(Firestop System Details / UL Detail Drawing)
Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT
English
-
W-J-3198
(Firestop System Details / UL Detail Drawing)
Blank or cables through Firestop Retrofit Sleeve Kit
English
-
W-J-5066
(Approval document / Penetration)
Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)
English
-
W-J-3199
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Firestop Sleeve Kit
English
-
F-C-7055
(Approval document / Penetration)
Max. 4" sheet metal duct with 1" thick duct wrap
English
-
F-E-1004
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")
English
-
W-J-1222
(Approval document / Penetration)
Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve
English
-
F-C-7043
(Firestop System Details / UL Detail Drawing)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
W-J-1128
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT
English
-
F-C-8044
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")
English
-
W-J-3200
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Cable Management Devices using Firestop Gangplate
English
-
W-J-3190
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (optional 45º angle)
English
-
W-J-1174
(Firestop System Details / UL Detail Drawing)
Max. 6" cast iron with "No-Hub" Connector
English
-
F-C-7042
(Approval document / Penetration)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-J-2242
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-5058
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation
English
-
F-C-5037
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation
English
-
W-J-5066
(Firestop System Details / UL Detail Drawing)
Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)
English
-
W-J-3036
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve optional)
English
-
W-J-1175
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
F-E-5013
(Firestop System Details / UL Detail Drawing)
Max. 2" steel or copper pipe with max. 1-1/2" glass fiber
English
-
F-E-8008
(Firestop System Details / UL Detail Drawing)
HVAC Line Set
English
-
W-J-1174
(Approval document / Penetration)
Max. 6" cast iron with "No-Hub" Connector
English
-
W-J-2242
(Approval document / Penetration)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-1201
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
F-C-7025
(Approval document / Penetration)
Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper
English
-
W-J-5042
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or 6" copper with 2" glass-fiber insulation
English
-
W-J-3199
(Approval document / Penetration)
Blank or cables through Firestop Sleeve Kit
English
-
W-J-4060
(Approval document / Penetration)
Cable Tray (36" x 6")
English
-
W-J-1124
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-3200
(Firestop System Details / UL Detail Drawing)
Blank or cables through Cable Management Devices using Firestop Gangplate
English
-
W-J-3197
(CAD/BIM Typicals / Auto CAD drawing file)
Cables (various) through Firestop Cable Transit
English
-
W-J-4030
(Approval document / Penetration)
Cable Tray
English
-
W-J-3143
(Approval document / Penetration)
Cable bundle (various cables) (sleeve optional)
English
-
W-J-1191
(Approval document / Penetration)
Multiple max. 2" steel, steel conduits, or EMT
English
-
F-C-7036
(Firestop System Details / UL Detail Drawing)
Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics
English
-
W-J-3111
(Approval document / Penetration)
English
-
W-J-4049
(Approval document / Penetration)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
F-C-8032
(CAD/BIM Typicals / Auto CAD drawing file)
Double HVAC Line Set (no pvc drain)
English
-
W-J-4027
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
F-C-8038
(Approval document / Penetration)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")
English
-
W-J-3188
(Firestop System Details / UL Detail Drawing)
Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")
English
-
W-J-1191
(Firestop System Details / UL Detail Drawing)
Multiple max. 2" steel, steel conduits, or EMT
English
-
W-J-3050
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeved)
English
-
W-J-5003
(Approval document / Penetration)
Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation
English
-
W-J-5042
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or 6" copper with 2" glass-fiber insulation
English
-
F-E-1004
(Approval document / Penetration)
Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")
English
-
F-C-5066
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber
English
-
W-J-2241
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-1168
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT
English
-
F-E-3005
(Firestop System Details / UL Detail Drawing)
Cable bundle (various) (AS = 3/4")
English
-
W-J-1210
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")
English
-
W-J-5136
(Approval document / Penetration)
Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-J-1089
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
F-E-7008
(Approval document / Penetration)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
W-J-3092
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (PVC Sleeve)
English
-
W-J-5028
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)
English
-
W-J-5136
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-J-1116
(Firestop System Details / UL Detail Drawing)
Max. 2" steel conduit or EMT (one or more)
English
-
W-J-4027
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
W-J-3190
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (optional 45º angle)
English
-
F-E-3005
(Approval document / Penetration)
Cable bundle (various) (AS = 3/4")
English
-
F-C-8038
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")
English
-
F-C-7013
(Firestop System Details / UL Detail Drawing)
Max. 4" diameter sheet metal duct w/o damper (min 28Ga)
English
-
W-J-4030
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
W-J-5057
(Approval document / Penetration)
Max. 10" steel pipe with max. 3" thick glass-fiber insulation
English
-
W-J-2229
(Approval document / Penetration)
Max. 1" PEX (bundled) (c,v) through CP 653 Speed Sleeve
English
-
W-J-3167
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-1201
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
W-J-3197
(Approval document / Penetration)
Cables (various) through Firestop Cable Transit
English
-
W-J-3061
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (shaft wall)
English
-
W-J-5028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)
English
-
F-C-7013
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" diameter sheet metal duct w/o damper (min 28Ga)
English
-
W-J-5136
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-J-3074
(Approval document / Penetration)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
W-J-1124
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-1210
(Approval document / Penetration)
Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")
English
-
W-J-1215
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" steel, cast iron, steel conduit or EMT
English
-
W-J-3189
(Approval document / Penetration)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-J-3190
(Approval document / Penetration)
Cable bundle (various cables) (optional 45┬║ angle)
English
-
F-E-7008
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
W-J-3110
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through Unique Split Sleeve
English
-
W-J-4072
(Firestop System Details / UL Detail Drawing)
Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)
English
-
W-J-1214
(Approval document / Penetration)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-J-3200
(Approval document / Penetration)
English
-
W-J-1089
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
W-J-4030
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
W-J-3188
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")
English
-
W-J-3061
(Approval document / Penetration)
Cable bundle (various cables) (shaft wall)
English
-
F-E-1004
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")
English
-
F-C-7037
(Approval document / Penetration)
Max. 4" sheet metal duct with 1-1/2" thick duct wrap
English
-
F-C-5066
(Firestop System Details / UL Detail Drawing)
Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber
English
-
W-J-2230
(Approval document / Penetration)
Max. 2" ENT (one or more) through CP 653 Speed Sleeve
English
-
W-J-5058
(Approval document / Penetration)
Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation
English
-
F-C-7055
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" sheet metal duct with 1" thick duct wrap
English
-
W-J-4049
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
W-J-3112
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in Unique Split Sleeve or Threaded Sleeve
English
-
W-J-1210
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")
English
-
W-J-1222
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve
English
-
W-J-3092
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (PVC Sleeve)
English
-
W-J-4072
(CAD/BIM Typicals / Auto CAD drawing file)
Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)
English
-
F-C-7036
(CAD/BIM Typicals / Auto CAD drawing file)
Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics
English
-
W-J-2230
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" ENT (one or more) through CP 653 Speed Sleeve
English
-
W-J-1116
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel conduit or EMT (one or more)
English
-
F-C-7043
(Approval document / Penetration)
Max. 12" x 10" sheet metal duct (AS=0" to 1")
English
-
W-J-1226
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, steel conduit or EMT
English
-
F-C-5004
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)
English
-
W-J-1222
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve
English
-
F-E-5013
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel or copper pipe with max. 1-1/2" glass fiber
English
-
W-J-3112
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in unique split sleeve or threaded sleeve
English
-
W-J-5134
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
W-J-4059
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
W-J-1168
(Approval document / Penetration)
Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT
English
-
W-J-4049
(Firestop System Details / UL Detail Drawing)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
W-J-2241
(Approval document / Penetration)
Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")
English
-
W-J-3167
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve
English
-
F-E-3005
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various) (AS = 3/4")
English
-
W-J-4072
(Approval document / Penetration)
Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)
English
-
F-C-5037
(Firestop System Details / UL Detail Drawing)
Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation
English
-
W-J-1089
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)
English
-
W-J-4048
(Approval document / Penetration)
Cable Rack in max. 24" x 36" opening
English
-
W-J-3112
(Approval document / Penetration)
English
-
W-J-1175
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT
English
-
F-C-7042
(CAD/BIM Typicals / Auto CAD drawing file)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-J-4059
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
W-J-3110
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through Unique Split Sleeve
English
-
W-J-1215
(Firestop System Details / UL Detail Drawing)
Max. 3" steel, cast iron, steel conduit or EMT
English
-
W-L-0019
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel pipe sleeve
English
-
W-L-1402
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
W-J-8017
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-0015
(Approval document / Penetration)
Max. 24" x 36" blank opening
English
-
W-L-1176
(Firestop System Details / UL Detail Drawing)
Max. 2" EMT or steel conduits (one or more)
English
-
W-L-1462
(Approval document / Penetration)
Medical gas station outlet
English
-
W-L-1465
(Approval document / Penetration)
Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve
English
-
W-L-1389
(Firestop System Details / UL Detail Drawing)
Multiple max. 2" steel, steel conduit, or EMT
English
-
W-L-0015
(Firestop System Details / UL Detail Drawing)
Max. 24" x 36" blank opening
English
-
W-L-1176
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" EMT or steel conduits (one or more)
English
-
W-J-8022
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC Line Set
English
-
W-J-8017
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-1206
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-L-1111
(Approval document / Penetration)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
W-L-1249
(Approval document / Penetration)
Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)
English
-
W-L-0019
(Firestop System Details / UL Detail Drawing)
Max. 4" steel pipe sleeve
English
-
W-L-1402
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
W-L-1170
(Firestop System Details / UL Detail Drawing)
Max. 6" copper, (sleeved)
English
-
W-L-1359
(Approval document / Penetration)
Max. 6" cast iron with "No-Hub" Connector
English
-
W-J-8009
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle
English
-
W-L-1392
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)
English
-
W-L-1176
(Approval document / Penetration)
Max. 2" EMT or steel conduits (one or more)
English
-
W-L-1389
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 2" steel, steel conduit, or EMT
English
-
W-J-7021
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-L-0015
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 36" blank opening
English
-
W-L-0030
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)
English
-
W-J-8017
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-1408
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-J-7110
(Approval document / Penetration)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-J-8022
(Firestop System Details / UL Detail Drawing)
HVAC Line Set
English
-
W-L-1206
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-L-1406
(Approval document / Penetration)
Max. 8" steel, cast iron, steel conduit, max. 4" copper or EMT (UL Classified U336 or U366 Wall)
English
-
W-L-1367
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT
English
-
W-J-8049
(Approval document / Penetration)
Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)
English
-
W-L-0013
(Firestop System Details / UL Detail Drawing)
Max. 4" threaded steel conduit with plastic or metal bushings
English
-
W-J-7038
(Approval document / Penetration)
Max. 6" sheet metal duct w/o damper (Shaft Wall)
English
-
W-L-1170
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" copper, (sleeved)
English
-
W-J-8009
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle
English
-
W-L-1243
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" aluminum or steel flexible conduit
English
-
W-J-7021
(Firestop System Details / UL Detail Drawing)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-L-0042
(Approval document / Penetration)
Blank opening through Gypsum wall assembly
English
-
W-L-0030
(Firestop System Details / UL Detail Drawing)
Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)
English
-
W-L-1408
(Firestop System Details / UL Detail Drawing)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-L-1164
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-J-7039
(Approval document / Penetration)
Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)
English
-
W-J-8007
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)
English
-
W-J-8050
(Approval document / Penetration)
Multiple penetrating items through concrete block wall assembly (min. 5" thick)
English
-
W-L-1367
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT
English
-
W-L-1408
(Approval document / Penetration)
Multiple max. 4" steel, steel conduit, or EMT
English
-
W-J-7029
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation
English
-
W-L-0013
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" threaded steel conduit with plastic or metal bushings
English
-
W-L-0042
(CAD/BIM Typicals / Auto CAD drawing file)
Blank opening through gypsum wall assembly
English
-
W-L-1412
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")
English
-
W-L-1243
(Firestop System Details / UL Detail Drawing)
Max. 2" aluminum or steel flexible conduit
English
-
W-J-8018
(Approval document / Penetration)
Cable bundle Cable Rack (Telecom) (various cables)
English
-
W-L-1359
(Firestop System Details / UL Detail Drawing)
Max. 6" cast iron with "No-Hub" Connector
English
-
W-L-1175
(Approval document / Penetration)
Max. 4" EMT or steel conduit
English
-
W-L-1402
(Approval document / Penetration)
Max. 4" steel, cast iron, steel conduit or EMT (one or more)
English
-
W-L-1304
(Approval document / Penetration)
Max. 4" steel, cast iron, conduit, or EMT
English
-
W-L-1164
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-J-8007
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)
English
-
W-J-7112
(Approval document / Penetration)
Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/2" to 2")
English
-
W-L-1248
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-J-7029
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation
English
-
W-L-1252
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-L-0042
(Firestop System Details / UL Detail Drawing)
Blank opening through gypsum wall assembly
English
-
W-L-1148
(Approval document / Penetration)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
W-L-1412
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")
English
-
W-L-1111
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
W-J-7112
(Firestop System Details / UL Detail Drawing)
Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/4" to 3-1/2")
English
-
W-L-1359
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" cast iron with "No-Hub" Connector
English
-
W-J-7039
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)
English
-
W-L-1441
(Approval document / Penetration)
Max. 3" steel, cast iron, steel conduit, or EMT
English
-
W-L-1441
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3" steel, cast iron, steel conduit, or EMT
English
-
W-L-0014
(Approval document / Penetration)
Max. 24" x 36" blank opening
English
-
W-L-1248
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-L-1297
(Firestop System Details / UL Detail Drawing)
Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe
English
-
W-J-8049
(Firestop System Details / UL Detail Drawing)
Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)
English
-
W-L-0018
(Approval document / Penetration)
Max. 4" steel pipe sleeve
English
-
W-L-1464
(Approval document / Penetration)
Max. 1" single or bundled fledxible steel conduits
English
-
W-L-1111
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, max. 6" copper, conduit or max. 4" EMT
English
-
W-L-1243
(Approval document / Penetration)
Max. 2" aluminum or steel flexible conduit
English
-
W-J-7112
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/2" to 2")
English
-
W-L-1252
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-7039
(Firestop System Details / UL Detail Drawing)
Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)
English
-
W-J-8044
(Approval document / Penetration)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-1441
(Firestop System Details / UL Detail Drawing)
Max. 3" steel, cast iron, steel conduit, or EMT
English
-
W-L-1465
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve
English
-
W-L-1110
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
W-L-1095
(Firestop System Details / UL Detail Drawing)
Max. 1" steel, conduit or EMT pipes (one or more)
English
-
W-L-1248
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-L-1297
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe
English
-
W-J-8007
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)
English
-
W-J-7091
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 2-1/4")
English
-
W-J-8049
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)
English
-
W-L-1058
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 16" steel, max. 4" copper, in wire mesh sleeve
English
-
W-L-1464
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" single or bundled fledxible steel conduits
English
-
W-L-1360
(Approval document / Penetration)
Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT
English
-
W-L-1389
(Approval document / Penetration)
Multiple max. 2" steel, steel conduit, or EMT
English
-
W-L-1205
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-L-1252
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-J-7021
(Approval document / Penetration)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-J-8016
(Approval document / Penetration)
ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct
English
-
W-L-1289
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT pipe
English
-
W-L-1465
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve
English
-
W-L-1056
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve
English
-
W-L-1095
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" steel, conduit or EMT pipes (one or more)
English
-
W-J-8048
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)
English
-
W-J-7109
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 100" x 100" sheet metal duct (w/o damper) ((AS=0" to 2"))
English
-
W-J-8048
(Approval document / Penetration)
Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)
English
-
W-J-7091
(Firestop System Details / UL Detail Drawing)
Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 3-1/2")
English
-
W-J-7029
(Approval document / Penetration)
Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation
English
-
W-L-1058
(Firestop System Details / UL Detail Drawing)
Max. 16" steel, max. 4" copper, in wire mesh sleeve
English
-
W-L-1464
(Firestop System Details / UL Detail Drawing)
Max. 1" single or bundled fledxible steel conduits
English
-
W-J-7109
(Approval document / Penetration)
Max. 100" x 100" sheet metal duct (w/o damper) ((AS=0" to 2"))
English
-
W-L-1462
(Firestop System Details / UL Detail Drawing)
Medical gas station outlet
English
-
W-L-1056
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve
English
-
W-L-0043
(Approval document / Penetration)
Blank opening through Gypsum wall assembly
English
-
W-L-0030
(Approval document / Penetration)
Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)
English
-
W-J-7085
(Firestop System Details / UL Detail Drawing)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-L-1289
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, conduit, or EMT pipe
English
-
W-J-7110
(CAD/BIM Typicals / Auto CAD drawing file)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-L-1110
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
W-J-7085
(Approval document / Penetration)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-J-8048
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)
English
-
W-L-1290
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, copper, conduit, or EMT
English
-
W-L-1249
(Firestop System Details / UL Detail Drawing)
Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)
English
-
W-J-8044
(Firestop System Details / UL Detail Drawing)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-1462
(CAD/BIM Typicals / Auto CAD drawing file)
Medical gas station outlet
English
-
W-J-8022
(Approval document / Penetration)
HVAC Line Set
English
-
W-L-1056
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve
English
-
W-J-8050
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through concrete block wall assembly (min. 5" thick)
English
-
W-J-7085
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-L-1304
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, conduit, or EMT
English
-
W-L-1170
(Approval document / Penetration)
Max. 6" copper, (sleeved)
English
-
W-J-7110
(Firestop System Details / UL Detail Drawing)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-L-1297
(Approval document / Penetration)
Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe
English
-
W-L-1110
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve
English
-
W-L-1440
(Firestop System Details / UL Detail Drawing)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-L-0043
(Firestop System Details / UL Detail Drawing)
Blank opening through gypsum wall assembly
English
-
W-L-1289
(Approval document / Penetration)
Max. 4" steel, cast iron, copper, conduit, or EMT pipe
English
-
W-J-7038
(Firestop System Details / UL Detail Drawing)
Max. 6" sheet metal duct w/o damper (Shaft Wall)
English
-
W-L-1164
(Approval document / Penetration)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-L-1249
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)
English
-
W-J-8044
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-1148
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
W-J-8050
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through concrete block wall assembly (min. 5" thick)
English
-
W-L-1304
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, conduit, or EMT
English
-
W-L-1440
(Approval document / Penetration)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-L-1247
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-L-0013
(Approval document / Penetration)
Max. 4" threaded steel conduit with plastic or metal bushings
English
-
W-L-1440
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")
English
-
W-L-0043
(CAD/BIM Typicals / Auto CAD drawing file)
Blank opening through gypsum wall assembly
English
-
W-L-0012
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 15" blank opening
English
-
W-J-7038
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" sheet metal duct w/o damper (Shaft Wall)
English
-
W-L-1360
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT
English
-
W-L-0019
(Approval document / Penetration)
Max. 4" steel pipe sleeve
English
-
W-L-1148
(Firestop System Details / UL Detail Drawing)
Max. 8" steel or cast iron pipe or max. 4" conduit or EMT
English
-
W-L-1214
(Approval document / Penetration)
Max. 1" flexible steel conduit
English
-
W-L-0040
(Firestop System Details / UL Detail Drawing)
Max. 2-1/2" dia or 2" x 2" blank
English
-
W-L-1247
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-J-8008
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)
English
-
W-L-1165
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-L-1095
(Approval document / Penetration)
Max. 1" steel, conduit or EMT pipes (one or more)
English
-
W-L-1247
(Approval document / Penetration)
Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)
English
-
W-L-0012
(Firestop System Details / UL Detail Drawing)
Max. 30" x 15" blank opening
English
-
W-L-1360
(Firestop System Details / UL Detail Drawing)
Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT
English
-
W-J-8008
(Approval document / Penetration)
Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)
English
-
W-L-1214
(Firestop System Details / UL Detail Drawing)
Max. 1" flexible steel conduit
English
-
W-L-1367
(Approval document / Penetration)
Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT
English
-
W-J-8034
(Firestop System Details / UL Detail Drawing)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-1380
(Approval document / Penetration)
Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)
English
-
W-J-6003
(Approval document / Penetration)
Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")
English
-
W-L-0014
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 36" blank opening
English
-
W-J-7022
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct
English
-
W-J-8009
(Approval document / Penetration)
Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle
English
-
W-L-1380
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)
English
-
W-J-8008
(Firestop System Details / UL Detail Drawing)
Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)
English
-
W-L-1165
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-L-1058
(Approval document / Penetration)
Max. 16" steel, max. 4" copper, in wire mesh sleeve
English
-
W-L-1406
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, steel conduit, max. 4" copper or EMT (UL Classified U336 or U366 Wall)
English
-
W-L-0023
(Firestop System Details / UL Detail Drawing)
Max. 4" blank steel sleeve
English
-
W-J-7022
(Approval document / Penetration)
Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct
English
-
W-J-6003
(Firestop System Details / UL Detail Drawing)
Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")
English
-
W-L-1214
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" flexible steel conduit
English
-
W-J-8016
(CAD/BIM Typicals / Auto CAD drawing file)
ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct
English
-
W-J-8034
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-1206
(Approval document / Penetration)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-L-1175
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" EMT or steel conduit
English
-
W-L-0023
(Approval document / Penetration)
Max. 4" blank steel sleeve
English
-
W-L-0014
(Firestop System Details / UL Detail Drawing)
Max. 24" x 36" blank opening
English
-
W-L-1380
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)
English
-
W-L-1205
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-J-7091
(Approval document / Penetration)
Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 2-1/4")
English
-
W-J-8018
(Firestop System Details / UL Detail Drawing)
Cable bundle Cable Rack (Telecom) (various cables)
English
-
W-L-0012
(Approval document / Penetration)
Max. 30" x 15" blank opening
English
-
W-L-1412
(Approval document / Penetration)
Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")
English
-
W-L-0023
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" blank steel sleeve
English
-
W-L-0018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel pipe sleeve
English
-
W-J-6003
(CAD/BIM Typicals / Auto CAD drawing file)
Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")
English
-
W-L-1392
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)
English
-
W-J-8016
(Firestop System Details / UL Detail Drawing)
ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct
English
-
W-L-1175
(Firestop System Details / UL Detail Drawing)
Max. 4" EMT or steel conduit
English
-
W-J-8034
(Approval document / Penetration)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-1392
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)
English
-
W-L-1165
(Approval document / Penetration)
Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve
English
-
W-L-0018
(Firestop System Details / UL Detail Drawing)
Max. 4" steel pipe sleeve
English
-
W-L-1205
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)
English
-
W-J-8018
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle Cable Rack (Telecom) (various cables)
English
-
W-L-5029
(Approval document / Penetration)
Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation
English
-
W-L-8035
(Firestop System Details / UL Detail Drawing)
Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)
English
-
W-L-8013
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
F-A-5070
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-3185
(Firestop System Details / UL Detail Drawing)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
W-L-5261
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation
English
-
W-L-5240
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)
English
-
W-L-4060
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
W-L-5029
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation
English
-
W-L-3382
(Firestop System Details / UL Detail Drawing)
Cable bundle through gypsum wall assembly (0-12" annular space)
English
-
W-L-7069
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)
English
-
W-L-7143
(Firestop System Details / UL Detail Drawing)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-L-4019
(Approval document / Penetration)
Spine Cable Tray
English
-
W-L-3071
(Approval document / Penetration)
Cable bundle (SER power cables)
English
-
W-L-3296
(Approval document / Penetration)
Cable bundle (various cables)
English
-
W-L-5244
(Approval document / Penetration)
Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)
English
-
W-L-2537
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" PEX (bundled) through CP 653 Speed Sleeve
English
-
W-L-7124
(Firestop System Details / UL Detail Drawing)
Max. 32"Metal Fab Grease Duct (AS varies)
English
-
W-L-7040
(Approval document / Penetration)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-L-7059
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" sheet metal duct w/o damper with max. 1 1/2" thickness foil scrim glass fiber duct insulation
English
-
W-L-3335
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-3385
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (optional 45º angle)
English
-
W-L-5027
(Firestop System Details / UL Detail Drawing)
Max 2" steel, copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation within a steel sleeve
English
-
W-L-4049
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
W-L-5257
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
W-L-5274
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)
English
-
W-L-3139
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(sleeved)
English
-
W-L-3111
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-8015
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrants through gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)
English
-
W-L-8058
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, copper, conduit or EMT, cable bundle
English
-
W-L-3226
(Approval document / Penetration)
Cable bundle (various cables)(PW Southern steel sleeve)
English
-
W-L-3161
(Approval document / Penetration)
Cable bundle (various cables)(sleeved)(shaft wall)
English
-
W-L-3391
(Approval document / Penetration)
Blank or Cables (various) through Firestop Cable Transit
English
-
W-L-7153
(Approval document / Penetration)
Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")
English
-
W-L-3334
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-8019
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-7198
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" sheet metal duct (30 Ga)
English
-
W-L-3161
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeved)(shaft wall)
English
-
W-L-2568
(Approval document / Penetration)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-5259
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-5025
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)
English
-
W-L-5047
(Firestop System Details / UL Detail Drawing)
Max. 20" steel, max. 6" copper, conduit or max. 4" EMT pipe with max. 3" Paroc insulation (Steel sleeve optional)
English
-
W-L-3334
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-8086
(Approval document / Penetration)
Cable bundle and metallic pipe through CP 653 Speed Sleeve
English
-
W-L-2537
(Firestop System Details / UL Detail Drawing)
Max. 1" PEX (bundled) through CP 653 Speed Sleeve
English
-
W-L-3310
(CAD/BIM Typicals / Auto CAD drawing file)
MC Cables (max qty 3) (membrane penetration)
English
-
W-L-7121
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 30" x 24" air or grease duct with 1-1/2" thick Firemaster® Fast Wrap manufactured by Thermal Ceramics
English
-
W-L-7153
(Firestop System Details / UL Detail Drawing)
Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")
English
-
W-L-4050
(Approval document / Penetration)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
W-L-5126
(Approval document / Penetration)
Max. 10" steel pipe with max. 3" glass fiber insulation
English
-
W-L-2537
(Approval document / Penetration)
Max. 1" PEX (bundled) through CP 653 Speed Sleeve
English
-
W-L-8023
(Approval document / Penetration)
Max. 6" steel tube (16 Ga) and cables (Translogic)
English
-
W-L-8086
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle and metallic pipe through CP 653 Speed Sleeve
English
-
W-L-8019
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-7096
(Firestop System Details / UL Detail Drawing)
Max. 13" x 12" sheet metal duct w/o damper (no angles)
English
-
W-L-7040
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-L-3384
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-L-3394
(Firestop System Details / UL Detail Drawing)
Blank or cables through Firestop Sleeve Kit
English
-
W-L-5125
(Approval document / Penetration)
Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation
English
-
W-L-4081
(Firestop System Details / UL Detail Drawing)
Cable tray through gypsum wall assembly
English
-
W-L-4038
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
-
W-L-5260
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-4060
(Approval document / Penetration)
Cable Tray
English
-
W-L-3112
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(sleeved)
English
-
W-L-3071
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (SER power cables)
English
-
W-L-8023
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel tube (16 Ga) and cables (Translogic)
English
-
W-L-8085
(Approval document / Penetration)
HVAC Line Set through CP 653 Speed Sleeve
English
-
W-L-2567
(Approval document / Penetration)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-3335
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-8014
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
W-L-3213
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(PVC sleeve)
English
-
W-L-5244
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)
English
-
W-L-5144
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper with max. 2" thick glass fiber (Shaft Wall) (sleeved)
English
-
W-L-5028
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation
English
-
W-L-7154
(Approval document / Penetration)
Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")
English
-
W-L-5096
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)
English
-
W-L-3316
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through Unique Sleeves with "gang plate"
English
-
W-L-3296
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)
English
-
W-L-7130
(CAD/BIM Typicals / Auto CAD drawing file)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-L-7155
(Firestop System Details / UL Detail Drawing)
Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")
English
-
W-L-3139
(Approval document / Penetration)
Cable bundle (various cables)(sleeved)
English
-
W-L-3272
(Approval document / Penetration)
Cable bundle (various cables)(sleeved)
English
-
W-L-7096
(Approval document / Penetration)
Max. 13" x 12" sheet metal duct w/o damper (no angles)
English
-
W-L-7042
(Approval document / Penetration)
Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct
English
-
W-L-5257
(Approval document / Penetration)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
W-L-3282
(Approval document / Penetration)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-2567
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-3079
(Approval document / Penetration)
Cable bundle (various cables)(sleeve optional)
English
-
W-L-7068
(Firestop System Details / UL Detail Drawing)
Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)
English
-
W-L-7017
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" diameter sheet metal duct w/o damper
English
-
W-L-3391
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or Cables (various) through Firestop Cable Transit
English
-
W-L-3396
(Firestop System Details / UL Detail Drawing)
Cable Bundle (various cables) (optional steel pipe sleeve)
English
-
W-L-3394
(Approval document / Penetration)
Blank or cables through Firestop Sleeve Kit
English
-
W-L-4050
(Firestop System Details / UL Detail Drawing)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
W-L-7158
(Approval document / Penetration)
Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-4019
(CAD/BIM Typicals / Auto CAD drawing file)
Spine Cable Tray
English
-
W-L-5263
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-L-6017
(Firestop System Details / UL Detail Drawing)
Max. 12" x 4" Fiber Optic Cable Tray (ABS)
English
-
W-L-5292
(Approval document / Penetration)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
W-L-3079
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(sleeve optional)
English
-
W-L-3058
(CAD/BIM Typicals / Auto CAD drawing file)
Cable (telephone cable)
English
-
W-L-8047
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC Line Set (AS varies)
English
-
W-L-8079
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)
English
-
W-L-7157
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-3224
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-3273
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-5028
(Approval document / Penetration)
Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. " AB/PVC insulation
English
-
W-L-5126
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel pipe with max. 3" glass fiber insulation
English
-
W-L-5046
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve
English
-
W-L-5126
(Firestop System Details / UL Detail Drawing)
Max. 10" steel pipe with max. 3" glass fiber insulation
English
-
W-L-5046
(Approval document / Penetration)
Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve
English
-
W-L-3307
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (UL Classified U336 or U366 Wall)
English
-
W-L-3278
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (shaft wall) (AS=0" to 1")
English
-
W-L-7151
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 60" x 36" sheet metal duct (w/o damper) with max. 2" thick glass fiber duct insulation (optional angles fastened through insulation) (AS=1/4" to 2-1/4")
English
-
W-L-7157
(Firestop System Details / UL Detail Drawing)
Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-8059
(Approval document / Penetration)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-4034
(Approval document / Penetration)
Aluminum Cable Tray (24" x 4") (AS=0" to 5")
English
-
W-L-8079
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)
English
-
W-L-3046
(Firestop System Details / UL Detail Drawing)
Cable bundle (power cables)Steel sleeve
English
-
W-L-6017
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" x 4" Fiber Optic Cable Tray (ABS)
English
-
W-L-3393
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Firestop Retrofit Sleeve Kit
English
-
W-L-7188
(Approval document / Penetration)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-L-4019
(Firestop System Details / UL Detail Drawing)
Spine Cable Tray
English
-
W-L-4048
(Firestop System Details / UL Detail Drawing)
Cable Rack in max. 24" x 36" opening
English
-
W-L-3396
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Bundle (various cables) (optional steel pipe sleeve)
English
-
W-L-5292
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
W-L-7017
(Firestop System Details / UL Detail Drawing)
Max. 6" diameter sheet metal duct w/o damper
English
-
W-L-3065
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")
English
-
W-L-3065
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")
English
-
W-L-3046
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (power cables)Steel sleeve
English
-
W-L-8059
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-3307
(Approval document / Penetration)
Cable bundle (various cables) (UL Classified U336 or U366 Wall)
English
-
W-L-5240
(Approval document / Penetration)
Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)
English
-
W-L-7018
(Approval document / Penetration)
Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)
English
-
W-L-7124
(Approval document / Penetration)
Max. 32" Metal Fab Grease Duct (AS varies)
English
-
W-L-3224
(Approval document / Penetration)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-3185
(Approval document / Penetration)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
W-L-7188
(Firestop System Details / UL Detail Drawing)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-L-7155
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")
English
-
W-L-3272
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeved)
English
-
W-L-3278
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (shaft wall) (AS=0" to 1")
English
-
W-L-7151
(Approval document / Penetration)
Max. 60" x 36" sheet metal duct (w/o damper) with max. 2" thick glass fiber duct insulation (optional angles fastened through insulation) (AS=1/4" to 2-1/4")
English
-
W-L-5096
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)
English
-
W-L-5073
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve
English
-
W-L-3282
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-3273
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-7154
(CAD/BIM Typicals / Auto CAD drawing file)
Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")
English
-
W-L-6017
(Approval document / Penetration)
Max. 12" x 4" Fiber Optic Cable Tray (ABS)
English
-
W-L-3046
(Approval document / Penetration)
Cable bundle (power cables)Steel sleeve
English
-
W-L-8085
(Firestop System Details / UL Detail Drawing)
HVAC Line Set through CP 653 Speed Sleeve
English
-
W-L-2568
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-3058
(Firestop System Details / UL Detail Drawing)
Cable (telephone cable)
English
-
W-L-4049
(Approval document / Penetration)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
W-L-7018
(Firestop System Details / UL Detail Drawing)
Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)
English
-
W-L-3395
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Cable Mangagment Devices using Firestop Gangplate
English
-
W-L-5143
(Approval document / Penetration)
Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)
English
-
W-L-4034
(Firestop System Details / UL Detail Drawing)
Aluminum Cable Tray (24" x 4") (AS=0" to 5")
English
-
W-L-3394
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through Firestop Sleeve Kit
English
-
W-L-7040
(Firestop System Details / UL Detail Drawing)
Max. 48" x 24" sheet metal duct w/o damper
English
-
W-L-3047
(Firestop System Details / UL Detail Drawing)
Cable bundle (power cables)
English
-
W-L-8035
(Approval document / Penetration)
Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)
English
-
W-L-2567
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-8086
(Firestop System Details / UL Detail Drawing)
Cable bundle and metallic pipe through CP 653 Speed Sleeve
English
-
W-L-8015
(Approval document / Penetration)
Multiple penetrants through Gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)
English
-
W-L-5096
(Approval document / Penetration)
Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)
English
-
W-L-4081
(Approval document / Penetration)
Cable tray through Gypsum wall assembly
English
-
W-L-2538
(Approval document / Penetration)
Max. 2" ENT (one or more) through CP 653 Speed Sleeve
English
-
W-L-7158
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-7153
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")
English
-
W-L-3277
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeved)
English
-
W-L-3296
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)
English
-
W-L-5143
(Firestop System Details / UL Detail Drawing)
Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)
English
-
W-L-5125
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation
English
-
W-L-3277
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(sleeved)
English
-
W-L-3226
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(PW Southern steel sleeve)
English
-
W-L-7156
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/2" to 2")
English
-
W-L-7198
(Firestop System Details / UL Detail Drawing)
Max. 4" sheet metal duct (30 Ga)
English
-
W-L-3382
(Approval document / Penetration)
Cable bundle through Gypsum wall assembly (0-12" annular space)
English
-
W-L-7155
(Approval document / Penetration)
Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")
English
-
F-A-5070
(Approval document / Penetration)
English
-
W-L-3273
(Approval document / Penetration)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-8081
(Firestop System Details / UL Detail Drawing)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-5261
(Approval document / Penetration)
Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation
English
-
W-L-8058
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, copper, conduit or EMT, cable bundle
English
-
W-L-3047
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (power cables)
English
-
W-L-3071
(Firestop System Details / UL Detail Drawing)
Cable bundle (SER power cables)
English
-
W-L-6019
(Firestop System Details / UL Detail Drawing)
Max. 11-1/4" x 4-1/4" Electrical Busway
English
-
W-L-7069
(Approval document / Penetration)
Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)
English
-
W-L-5274
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)
English
-
W-L-4049
(Firestop System Details / UL Detail Drawing)
Multiple Cable Racks (optional) in max. 24" x 36" opening
English
-
W-L-4011
(Firestop System Details / UL Detail Drawing)
Aluminum Cable Tray (24" x 6") (AS=0" to 4")
English
-
W-L-3392
(CAD/BIM Typicals / Auto CAD drawing file)
Cables (various) through Firestop Cable Transit
English
-
W-L-6019
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 11-1/4" x 4-1/4" Electrical Busway
English
-
W-L-7059
(Approval document / Penetration)
Max. 24" x 12" sheet metal duct w/o damper with max. 1 ›" thickness foil scrim glass fiber duct insulation
English
-
W-L-7059
(Firestop System Details / UL Detail Drawing)
Max. 24" x 12" sheet metal duct w/o damper with max. 1 1/2" thickness foil scrim glass fiber duct insulation
English
-
W-L-2568
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)
English
-
W-L-8081
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-5259
(Approval document / Penetration)
Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-3278
(Approval document / Penetration)
Cable bundle (various cables) (shaft wall) (AS=0" to 1")
English
-
W-L-3111
(Approval document / Penetration)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-7157
(Approval document / Penetration)
Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-5274
(Approval document / Penetration)
Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)
English
-
W-L-3385
(Approval document / Penetration)
Cable bundle (various cables) (optional 45┬║ angle)
English
-
W-L-7156
(Firestop System Details / UL Detail Drawing)
Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/4" to 3-1/2")
English
-
W-L-7143
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-L-3282
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Unique Firestop Sleeve)
English
-
W-L-3310
(Firestop System Details / UL Detail Drawing)
MC Cables (max qty 3) (membrane penetration)
English
-
W-L-5125
(Firestop System Details / UL Detail Drawing)
Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation
English
-
W-L-5029
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation
English
-
W-L-5143
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)
English
-
W-L-5240
(Firestop System Details / UL Detail Drawing)
Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)
English
-
W-L-3272
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(sleeved)
English
-
W-L-8079
(Approval document / Penetration)
Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)
English
-
W-L-3220
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(Unique Firestop Sleeve)
English
-
W-L-7158
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax
English
-
W-L-8013
(Firestop System Details / UL Detail Drawing)
Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
W-L-5027
(Approval document / Penetration)
Max 2" steel, copper, conduit or EMT pipe with max. " AB/PVC insulation within a steel sleeve
English
-
W-L-8013
(Approval document / Penetration)
Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
W-L-8035
(CAD/BIM Typicals / Auto CAD drawing file)
Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)
English
-
W-L-3065
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")
English
-
W-L-8058
(Approval document / Penetration)
Insulated or non-insulated steel, copper, conduit or EMT, cable bundle
English
-
W-L-3111
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-5261
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation
English
-
W-L-4034
(CAD/BIM Typicals / Auto CAD drawing file)
Aluminum Cable Tray (24" x 4") (AS=0" to 5")
English
-
W-L-4060
(Firestop System Details / UL Detail Drawing)
Cable Tray
English
-
W-L-5223
(Approval document / Penetration)
Max. 12" steel or 6" copper with Nom. 1-1/2" or 3" thick Foam Glass pipe insulation
English
-
W-L-3385
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (optional 45º angle)
English
-
W-L-7018
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)
English
-
W-L-7069
(Firestop System Details / UL Detail Drawing)
Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)
English
-
W-L-3392
(Approval document / Penetration)
Cables (various) through Firestop Cable Transit
English
-
W-L-4038
(Approval document / Penetration)
Cable Tray
English
-
W-L-8085
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC Line Set through CP 653 Speed Sleeve
English
-
W-L-3393
(Approval document / Penetration)
Blank or cables through Firestop Retrofit Sleeve Kit
English
-
W-L-7198
(Approval document / Penetration)
Max. 4" sheet metal duct (30 Ga)
English
-
W-L-3396
(Approval document / Penetration)
Cable Bundle (various cables) (optional steel pipe sleeve)
English
-
W-L-3058
(Approval document / Penetration)
Cable (telephone cable)
English
-
W-L-3310
(Approval document / Penetration)
MC Cables (max qty 3) (membrane penetration)
English
-
W-L-7154
(Firestop System Details / UL Detail Drawing)
Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")
English
-
W-L-7017
(Approval document / Penetration)
Max. 6" diameter sheet metal duct w/o damper
English
-
W-L-7124
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 32"Metal Fab Grease Duct (AS varies)
English
-
W-L-3307
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (UL Classified U336 or U366 Wall)
English
-
W-L-2538
(Firestop System Details / UL Detail Drawing)
Max. 2" ENT (one or more) through CP 653 Speed Sleeve
English
-
W-L-5073
(Firestop System Details / UL Detail Drawing)
Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve
English
-
W-L-5027
(CAD/BIM Typicals / Auto CAD drawing file)
Max 2" steel, copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation within a steel sleeve
English
-
W-L-5223
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel or 6" copper with Nom. 1-1/2" or 3" thick Foam Glass pipe insulation
English
-
W-L-7130
(Approval document / Penetration)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-L-5257
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
-
W-L-3224
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (sleeve optional)
English
-
W-L-3185
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle Cable Rack (Telecom) (various Cables)
English
-
W-L-7188
(CAD/BIM Typicals / Auto CAD drawing file)
Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")
English
-
W-L-8015
(Firestop System Details / UL Detail Drawing)
Multiple penetrants through gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)
English
-
W-L-3220
(Approval document / Penetration)
Cable bundle (various cables)(Unique Firestop Sleeve)
English
-
W-L-3213
(Approval document / Penetration)
Cable bundle (various cables)(PVC sleeve)
English
-
W-L-7143
(Approval document / Penetration)
Max. 24" x 24" sheet metal duct w/o damper (no angles)
English
-
W-L-6019
(Approval document / Penetration)
Max. 11-1/4" x 4-1/4" Electrical Busway
English
-
W-L-3316
(Approval document / Penetration)
Cable bundle (various cables) through Unique Sleeves with "gang plate"
English
-
W-L-8059
(Firestop System Details / UL Detail Drawing)
Multiple steel pipe, steel conduit, EMT and/or cable bundle
English
-
W-L-8019
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)
English
-
W-L-3079
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeve optional)
English
-
F-A-5070
(Firestop System Details / UL Detail Drawing)
English
-
W-L-3047
(Approval document / Penetration)
Cable bundle (power cables)
English
-
W-L-5292
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation
English
-
W-L-5259
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-4048
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Rack in max. 24" x 36" opening
English
-
W-L-5025
(Firestop System Details / UL Detail Drawing)
Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)
English
-
W-L-3393
(Firestop System Details / UL Detail Drawing)
Blank or cables through Firestop Retrofit Sleeve Kit
English
-
W-L-3382
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle through gypsum wall assembly (0-12" annular space)
English
-
W-L-7042
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct
English
-
W-L-7121
(Firestop System Details / UL Detail Drawing)
Max. 30" x 24" air or grease duct with 1-1/2" thick Firemaster® Fast Wrap manufactured by Thermal Ceramics
English
-
W-L-2538
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" ENT (one or more) through CP 653 Speed Sleeve
English
-
W-L-4048
(Approval document / Penetration)
Cable Rack in max. 24" x 36" opening
English
-
W-L-5144
(Approval document / Penetration)
Max. 1" copper with max. 2" thick glass fiber (Shaft Wall) (sleeved)
English
-
W-L-8047
(Approval document / Penetration)
HVAC Line Set (AS varies)
English
-
W-L-8014
(Approval document / Penetration)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
W-L-7096
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 13" x 12" sheet metal duct w/o damper (no angles)
English
-
W-L-3316
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through Unique Sleeves with "gang plate"
English
-
W-L-3335
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-5073
(Approval document / Penetration)
Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve
English
-
W-L-5046
(Firestop System Details / UL Detail Drawing)
Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve
English
-
W-L-4081
(CAD/BIM Typicals / Auto CAD drawing file)
Cable tray through gypsum wall assembly
English
-
W-L-5260
(Firestop System Details / UL Detail Drawing)
Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-5025
(Approval document / Penetration)
Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)
English
-
W-L-3213
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables)(PVC sleeve)
English
-
W-L-3139
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeved)
English
-
W-L-8023
(Firestop System Details / UL Detail Drawing)
Max. 6" steel tube (16 Ga) and cables (Translogic)
English
-
W-L-3395
(Approval document / Penetration)
Blank or cables through Cable Mangagment Devices using Firestop Gangplate
English
-
W-L-8081
(Approval document / Penetration)
Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")
English
-
W-L-3384
(Approval document / Penetration)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-L-8047
(Firestop System Details / UL Detail Drawing)
HVAC Line Set (AS varies)
English
-
W-L-8014
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)
English
-
W-L-3112
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables)(sleeved)
English
-
W-L-5263
(Approval document / Penetration)
Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-L-5263
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")
English
-
W-L-5244
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)
English
-
W-L-4050
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple Cable Racks (optional) in max. 36" x 48" opening
English
-
W-L-7156
(Approval document / Penetration)
Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/2" to 2")
English
-
W-L-5028
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation
English
-
W-L-3384
(Firestop System Details / UL Detail Drawing)
Cable Bundle (various cables) through "ganged" Speed Sleeves
English
-
W-L-3334
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables through CP 653 Speed Sleeve
English
-
W-L-7068
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)
English
-
W-L-7130
(Firestop System Details / UL Detail Drawing)
Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)
English
-
W-L-3112
(Approval document / Penetration)
Cable bundle (various cables)(sleeved)
English
-
W-L-3277
(Approval document / Penetration)
Cable bundle (various cables)(sleeved)
English
-
W-L-5260
(Approval document / Penetration)
Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)
English
-
W-L-7068
(Approval document / Penetration)
Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)
English
-
TP-CS-SL SA
(Firestop System Details / UL Detail Drawing)
Through penetration for non fire-rated smoke partitions
English
-
F-C-2416
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-2684
(Firestop System Details / UL Detail Drawing)
English
-
F-C-1168
(Approval document / Penetration)
Max. 3/4" steel, iron, conduit, or EMT pipe; Max. 1/2" copper tubing or copper pipe; AS = Min. 0"
English
-
F-B-2053
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-0141
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 24” blank opening (Mineral Wool & Silicone Sealant)
English
-
HI/PF 120-04
(Approval document / Penetration)
English
-
W-L-5011
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8098
(Approval document / Penetration)
Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)
English
-
F-A-1136
(Approval document / Penetration)
English
-
F-C-7058
(Approval document / Penetration)
English
-
W-L-0005
(Approval document / Penetration)
English
-
W-L-3234
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through gypsum board wall (Max. 34% fill) in unique threaded sleeve or threaded split sleeve
English
-
C-AJ-8248
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2027
(Firestop System Details / UL Detail Drawing)
English
-
F-A-5047
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2027
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-0024
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8093
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through gypsum wall assembly (various cable and pipe sizes)
English
-
W-L-3413
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7153
(Approval document / Penetration)
English
-
F-C-2045
(Approval document / Penetration)
English
-
W-J-2032
(Firestop System Details / UL Detail Drawing)
English
-
W-L-5011
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-2080
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1664
(Approval document / Penetration)
English
-
W-J-3215
(Approval document / Penetration)
Cable bundle; VF = 0 - 100%; AS = Min. 0"
English
-
F-C-2035
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1661
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1661
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-7152
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-2416
(Firestop System Details / UL Detail Drawing)
English
-
F-C-1168
(Firestop System Details / UL Detail Drawing)
Max. 3/4" steel, iron, conduit, or EMT pipe; Max. 1/2" copper tubing or copper pipe; AS = Min. 0"
English
-
C-AJ-8014
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-2416
(Approval document / Penetration)
English
-
W-L-2062
(Approval document / Penetration)
English
-
C-AJ-1612
(Firestop System Details / UL Detail Drawing)
English
-
W-J-7123
(Firestop System Details / UL Detail Drawing)
English
-
W-L-3413
(Approval document / Penetration)
English
-
HI/PF 120-05
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2317
(Approval document / Penetration)
English
-
C-AJ-2677
(Approval document / Penetration)
English
-
C-AJ-7154
(Firestop System Details / UL Detail Drawing)
English
-
C-BJ-1069
(Approval document / Penetration)
English
-
C-AJ-6048
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8098
(Firestop System Details / UL Detail Drawing)
Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)
English
-
F-A-3073
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-0142
(Firestop System Details / UL Detail Drawing)
Max. 6” blank opening (Mineral Wool & Silicone Sealant)
English
-
F-A-2310
(Approval document / Penetration)
English
-
W-L-2061
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-3415
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle, Visual Fill = 0 - 100%; AS = Min. 0"
English
-
W-L-7214
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7150
(Approval document / Penetration)
English
-
W-J-2030
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2565
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2029
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-4106
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-7153
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-3414
(Approval document / Penetration)
Cable bundle; VF = 0 - 100%; AS = Min. 0"
English
-
F-C-5088
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel pipe, iron pipe, copper tubing, copper pipe
English
-
C-AJ-2079
(Approval document / Penetration)
English
-
F-C-5088
(Approval document / Penetration)
Max. 4" steel pipe, iron pipe, copper tubing, or copper pipe
English
-
C-AJ-2677
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-6048
(Firestop System Details / UL Detail Drawing)
English
-
F-C-1168
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 3/4" steel, iron, conduit or EMT; Max. 1/2" copper tubing or pipe; AS = Min. 0"
English
-
W-L-2052
(Approval document / Penetration)
English
-
W-L-3414
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle, Visual Fill = 0 - 100%; AS = Min. 0"
English
-
C-AJ-8014
(Firestop System Details / UL Detail Drawing)
English
-
F-C-7059
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HI/PF 120-03
(Approval document / Penetration)
English
-
W-K-3002
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Bundle (Max. 100% visual fill)
English
-
F-B-2011
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-7149
(Approval document / Penetration)
English
-
W-L-2062
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-7059
(Approval document / Penetration)
English
-
F-B-1032
(Approval document / Penetration)
Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)
English
-
C-AJ-4106
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8094
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through gypsum wall assembly (various cable and cable bundle sizes)
English
-
W-K-3002
(Firestop System Details / UL Detail Drawing)
Cable Bundle (Max. 100% visual fill)
English
-
C-AJ-7150
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-1630
(Approval document / Penetration)
English
-
F-C-2035
(Firestop System Details / UL Detail Drawing)
English
-
W-J-7124
(Firestop System Details / UL Detail Drawing)
English
-
HI/PF 120-05
(Approval document / Penetration)
English
-
W-L-2565
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-5069
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2061
(Approval document / Penetration)
English
-
W-J-2029
(Approval document / Penetration)
English
-
C-AJ-7149
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-2684
(Approval document / Penetration)
English
-
W-J-2029
(Firestop System Details / UL Detail Drawing)
English
-
F-B-1032
(Firestop System Details / UL Detail Drawing)
Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)
English
-
F-A-1136
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1662
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-1661
(Approval document / Penetration)
English
-
F-A-3073
(Approval document / Penetration)
English
-
W-L-3233
(Approval document / Penetration)
Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded sleeve
English
-
HI/PF 60-01
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-2031
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-2079
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7152
(Approval document / Penetration)
English
-
W-L-7213
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-2053
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-BJ-1069
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-6048
(Approval document / Penetration)
English
-
C-AJ-7151
(Firestop System Details / UL Detail Drawing)
English
-
W-L-7214
(Approval document / Penetration)
English
-
C-AJ-8014
(Approval document / Penetration)
English
-
W-L-3233
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded sleeve
English
-
TP-CS-SL SA
(CAD/BIM Typicals / Auto CAD drawing file)
Through penetration for non fire-rated smoke partitions
English
-
F-A-5047
(Approval document)
English
-
C-AJ-0142
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6” blank opening (Mineral Wool & Silicone Sealant)
English
-
HI/PF 120-04
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2316
(Approval document / Penetration)
English
-
F-B-2010
(Approval document)
English
-
C-AJ-2678
(Firestop System Details / UL Detail Drawing)
English
-
W-J-3215
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle, Visual fill = 0 - 100%; AS = Min. 0"
English
-
F-A-5047
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-2045
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-2031
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2060
(Firestop System Details / UL Detail Drawing)
English
-
F-C-3110
(Firestop System Details / UL Detail Drawing)
Cable bundle, VF = 0 - 100%; AS = Min. 0"
English
-
C-AJ-2674
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-2051
(Firestop System Details / UL Detail Drawing)
English
-
W-J-7123
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-8218
(Approval document)
English
-
F-B-2008
(Approval document)
English
-
F-A-5069
(Firestop System Details / UL Detail Drawing)
English
-
W-L-0005
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2219
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2219
(Approval document)
English
-
C-AJ-2080
(Approval document)
English
-
W-J-7123
(Approval document)
English
-
W-L-2057
(Approval document)
English
-
W-L-2578
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HI/PF 120-02
(Approval document)
English
-
F-B-2010
(Firestop System Details / UL Detail Drawing)
English
-
F-C-7058
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-5011
(Approval document)
English
-
C-AJ-1662
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-1032
(CAD/BIM Typicals / Auto CAD drawing file)
Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)
English
-
F-B-2049
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2578
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2032
(Approval document)
English
-
C-AJ-2678
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2060
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-2027
(Approval document)
English
-
W-L-3230
(CAD/BIM Typicals / Auto CAD drawing file)
Angled cable membrane penetration through gypsum board wall (Max. 0.4 sq. in.)
English
-
W-J-0024
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2603
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1-1/4" PP pipe (c)
English
-
W-L-0005
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-0142
(Approval document / Penetration)
Max. 6” blank opening (Mineral Wool & Silicone Sealant)
English
-
C-AJ-8248
(Approval document)
English
-
W-L-8093
(Firestop System Details / UL Detail Drawing)
Multiple penetrating items through gypsum wall assembly (various cable and pipe sizes)
English
-
C-AJ-8248
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7149
(Firestop System Details / UL Detail Drawing)
English
-
W-L-3415
(Approval document / Penetration)
Cable bundle; VF = 0 - 100%; AS = Min. 0"
English
-
F-B-2008
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-7151
(Approval document)
English
-
F-C-3110
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle, Visual fill 0-100%; AS = Min. 0"
English
-
F-C-2035
(Approval document)
English
-
HI/PF 120-01
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-7214
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2030
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2603
(Approval document / Penetration)
Max. 1-1/4" PP pipe (c)
English
-
C-AJ-1663
(Approval document)
English
-
F-B-2011
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1664
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-7154
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-1033
(Approval document / Penetration)
Nom. 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)
English
-
C-AJ-1612
(Approval document)
English
-
C-AJ-7151
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2317
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1612
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-C-7057
(Approval document)
English
-
C-AJ-2079
(Firestop System Details / UL Detail Drawing)
English
-
W-L-7213
(Firestop System Details / UL Detail Drawing)
English
-
HI/PF 120-03
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-2011
(Approval document)
English
-
C-AJ-2674
(Approval document)
English
-
C-AJ-1664
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1663
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2316
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7153
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-2678
(Approval document)
English
-
W-J-2032
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8094
(Approval document / Penetration)
Multiple penetrating items through Gypsum wall assembly (various cable and cable bundle sizes)
English
-
W-L-2057
(Firestop System Details / UL Detail Drawing)
English
-
W-L-7213
(Approval document)
English
-
W-L-3413
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-5098
(Approval document / Penetration)
Max. 6" steel or copper pipe with max. 3" thick glass fiber insulation (Steel sleeve optional) (AS=1/2")
English
-
W-L-3230
(Approval document / Penetration)
Angled cable membrane penetration through gypsum board wall (Max. 0.4 sq. in.)
English
-
W-L-2061
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2052
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7150
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-2030
(Approval document)
English
-
C-AJ-8218
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1663
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2060
(Approval document)
English
-
C-AJ-1662
(Approval document)
English
-
F-A-2219
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2062
(Firestop System Details / UL Detail Drawing)
English
-
F-A-2156
(Firestop System Details / UL Detail Drawing)
English
-
W-L-3232
(Approval document / Penetration)
Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded split sleeve
English
-
HI/PF 60-01
(Approval document)
English
-
HI/PF 120-01
(Approval document / Penetration)
English
-
F-C-7057
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-K-3002
(Approval document / Penetration)
Cable Bundle (Max. 100% visual fill)
English
-
F-A-2317
(Firestop System Details / UL Detail Drawing)
English
-
W-L-8093
(Approval document / Penetration)
Multiple penetrating items through Gypsum wall assembly (various cable and pipe sizes)
English
-
W-L-2565
(Approval document)
English
-
C-AJ-8249
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-8249
(Approval document)
English
-
F-A-1136
(Firestop System Details / UL Detail Drawing)
English
-
F-B-1033
(Firestop System Details / UL Detail Drawing)
Nom. 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)
English
-
C-AJ-0141
(Approval document / Penetration)
Max. 24” blank opening (Mineral Wool & Silicone Sealant)
English
-
W-J-2031
(Approval document)
English
-
F-C-2045
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2578
(Approval document)
English
-
C-BJ-1069
(Firestop System Details / UL Detail Drawing)
English
-
W-L-2057
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-3232
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded split sleeve
English
-
F-C-3110
(Approval document / Penetration)
Cable bundle; VF = 0 - 100%; AS = Min. 0"
English
-
W-L-8098
(CAD/BIM Typicals / Auto CAD drawing file)
Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)
English
-
F-B-2049
(Approval document)
English
-
C-AJ-5098
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" steel or copper pipe with max. 3" thick glass fiber insulation (Steel sleeve optional) (AS=1/2")
English
-
W-L-2052
(Firestop System Details / UL Detail Drawing)
English
-
F-B-2008
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-2684
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-2310
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-2053
(Approval document)
English
-
W-L-3234
(Approval document / Penetration)
Cable bundle (various cables) through gypsum board wall (Max. 34% fill) in unique threaded sleeve or threaded split sleeve
English
-
HI/PF 120-02
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-1630
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-1033
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)
English
-
C-AJ-2080
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-2674
(Firestop System Details / UL Detail Drawing)
English
-
F-C-5088
(Firestop System Details / UL Detail Drawing)
Max. 4" steel pipe, iron pipe, copper tubing, copper pipe
English
-
W-J-7124
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7154
(Approval document / Penetration)
English
-
W-L-8094
(CAD/BIM Typicals / Auto CAD drawing file)
Multiple penetrating items through gypsum wall assembly (various cable and cable bundle sizes)
English
-
F-B-2010
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-7124
(Approval document)
English
-
W-L-2649
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 6" Cosmoplast PP-R pipe or HDPE, or Max. 4" Coprax or Aquatherm Greenpipe PP-R pipe (AS varies) (Sheet Metal Sleeve, CP 648E wrap insert & FS-ONE MAX)
English
-
W-L-2676
(Firestop System Details / UL Detail Drawing)
Max. 2" ENT (AS=0" to 1/2")
English
-
W-L-8110
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set through Firestop Sleeve Kit
English
-
(DWG) W-J-5194
(CAD/BIM Typicals / Auto CAD drawing file)
One or more Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation (Max Qty. = 4) (Sealant, wrap strip & retaining collar)
English
-
ASSET_DOC_LOC_8844106
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation
English
-
C-BJ-3039
(Approval document / Penetration)
English
-
W-L-7277
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-8110
(Firestop System Details / UL Detail Drawing)
HVAC line set through Firestop Sleeve Kit
English
-
F-A-5062
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" steel or copper pipe with nom. 1-1/2" thickness cellular glass (foamglass) insulation (4-1/2" concrete) (CP 680-P Cast-In Device)
English
-
W-J-2332
(Firestop System Details / UL Detail Drawing)
Max. 2" electrical non-metallic tubing (ENT)
English
-
W-J-8055
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7192
(Firestop System Details / UL Detail Drawing)
Max. 30” x 30” steel sheet metal air duct (w/o steel angles) (Min. 24 ga. for 2 hour, Min. 22 ga for 3 hour) (AS=1/2” to 1-1/2”)
English
-
F-B-1035
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, cast iron, copper, steel conduit, or EMT (through Concrete Floor or Hollow-Core Floor) inside Optional Gypsum Chase Wall
English
-
W-L-2744
(Firestop System Details / UL Detail Drawing)
English
-
W-L-5345
(Approval document / Penetration)
Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation
English
-
W-J-1299
(Firestop System Details / UL Detail Drawing)
English
-
W-L-4087
(Approval document / Penetration)
English
-
F-A-8047
(Approval document / Penetration)
Single HVAC Line Set through CFS-DID Firestop Drop-In Device 3" MD or C
English
-
W-L-5345
(Firestop System Details / UL Detail Drawing)
Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation
English
-
C-BJ-8038
(Approval document / Penetration)
English
-
F-C-2515
(Approval document / Penetration)
English
-
W-L-2677
(Approval document / Penetration)
Max. 2" electrical nonmetallic tubing (ENT)
English
-
W-J-8068
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set through Firestop Sleeve Kit
English
-
W-L-2694
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-1170
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-B-0005
(CAD/BIM Typicals / Auto CAD drawing file)
Blank CFS-CID M & P (6" concrete)
English
-
W-J-2332
(Approval document / Penetration)
Max. 2" electrical non-metallic tubing (ENT)
English
-
W-L-4087
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-J-1259
(Firestop System Details / UL Detail Drawing)
English
-
C-AJ-0155
(Firestop System Details / UL Detail Drawing)
Max 30" x 30" Blank opening with CFS-COS Firestop Composite Sheet (rigid foil-faced intumescent sheet with stainless steel backing) (min. 4-1/2" concrete) (4 hour)
English
-
ASSET_DOC_LOC_8593777
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
C-AJ-7199
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
F-A-8047
(Firestop System Details / UL Detail Drawing)
Single HVAC Line Set through CFS-DID Firestop Drop-In Device 3" MD or C
English
-
W-J-8068
(Firestop System Details / UL Detail Drawing)
HVAC line set through Firestop Sleeve Kit
English
-
F-B-2062
(Firestop System Details / UL Detail Drawing)
Nominal 8" or 10" XFR pipe (c,v) (6" concrete)
English
-
F-A-5062
(Approval document / Penetration)
Max. 2" steel or copper pipe with nom. 1-1/2" thickness cellular glass (foamglass) insulation (4-1/2" concrete) (CP 680-P Cast-In Device)
English
-
W-J-8055
(Approval document / Penetration)
English
-
C-AJ-7195
(Firestop System Details / UL Detail Drawing)
English
-
F-E-3021
(Approval document / Penetration)
Structural cement-fiber panel and steel truss floor-ceiling assembly for max 1" diameter cable bundle through penetrant.
English
-
TP-506
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-1518
(Firestop System Details / UL Detail Drawing)
English
-
C-BJ-8038
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
W-L-2766
(Firestop System Details / UL Detail Drawing)
English
-
W-J-2332
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" electrical non-metallic tubing (ENT)
English
-
F-B-2063
(Approval document / Penetration)
Max. 4" PVC, CPVC, or ABS (Concrete Floor or Hollow-Core Floor) inside optional Gypsum Chase Wall.
English
-
F-C-2515
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
TP-572
(Firestop System Details / UL Detail Drawing)
Through penetration systems for non-rated smoke partitions using CP 572
English
-
W-J-5190
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 1/2" PEX tubing with 3/4" thick AB/PVC pipe insulation (AS=1/4" to 7/8")
English
-
W-L-1597
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
CAD Detail (PDF) CT-L03-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-PS07-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) PL-SA02-C
(CAD/BIM Typicals)
English
-
Fastening to Steel Strut to Steel
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-PS56-C
(CAD/BIM Typicals)
English
-
Spec Section 26 05 29 for Hanger Supports for Electrical Systems
(Specification Text)
English
-
CAD Detail (PDF) CT-L07-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C09-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TP50-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-TR52-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-PS01-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP51-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-D50-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BF02-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-BC53-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TR53-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-BPS02-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP07-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F03-C
(CAD/BIM Typicals)
English
-
Fastening to Steel Decking
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC08-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR13-S
(CAD/BIM Typicals)
English
-
Fastening to Steel Grating
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-GP56-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TP50-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR57-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F51-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F10-C_S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC01-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR54-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TP04-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-P17-CS
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR50-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC05-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F06-C_S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP04-C
(CAD/BIM Typicals)
English
-
Fastening to Steel Grounding
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR61-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TR04-S
(CAD/BIM Typicals)
English
-
Spec Section 05 43 00 for Slotted Channel Framing
(Specification Text)
English
-
CAD Detail (PDF) P-GP11-NA
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR09-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC52-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-D53-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP11-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-BPS52-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-BC01-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR02-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C03-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C50-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-L04-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-PS51-C
(CAD/BIM Typicals)
English
-
Spec Section 05 50 60 for Pre-Engineered Modular Systems
(Specification Text)
French
-
CAD Detail (PDF) EI-PS55-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-L06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C10-S
(CAD/BIM Typicals)
English
-
HCS_Spec for Concrete Monitoring (Canada English).docx
(Specification Text)
Specification Text for Concrete Monitoring (Canada)
English
-
CAD Detail (PDF) CT-C05-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TP51-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-TR53-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-BPS54-NA
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) (CA-EN) for Decking
(CAD/BIM Typicals)
English
-
CAD Detail (DWG) (CA-EN) for Decking
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP50-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-D51-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BF01-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR07-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-BC56-S
(CAD/BIM Typicals)
English
-
Spec Section 22 05 29 for Hanger Supports for Plumbing and Piping Equipment
(Specification Text)
French
-
CAD Detail (PDF) P-TR51-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-BPS01-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP06-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F04-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC07-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR14-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-P06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TP23-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR56-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F50-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F11-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR55-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TP21-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-P16-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR15-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-F05-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP05-C
(CAD/BIM Typicals)
English
-
Spec Section 26 05 29 for Hanger Supports for Electrical Systems
(Specification Text)
French
-
CAD Detail (PDF) CT-TR62-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-TR25-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) P-GP06-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR08-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-BC53-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-D52-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-GP11-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-BPS53-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EI-TR54-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-TR01-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C04-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-C11-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) CT-L05-S
(CAD/BIM Typicals)
English
-
SDI DDM03 Appendix VII with Hilti Screws
(Approval document)
English
-
CAD Detail (PDF) EI-PS53-C
(CAD/BIM Typicals)
English
-
Fastening to Steel Electrical Connections
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-GP54-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete Over Metal Deck, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Cable Tray Supports, MI Details
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-Complete Set
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TR03-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Low Voltage Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Concrete Over Metal Deck, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TR53-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Equipment Supports, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-BC02-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-C05-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete Floor, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EQP-50-C
(CAD/BIM Typicals)
English
-
Quickstart Guide for PR 30-HVS Rotating Laser
(Brochure)
-
CAD Detail (PDF) TD-P-TP01-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Low Voltage Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Piping Supports, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-F16-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete Over Metal Deck, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) OHG-MED01- C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) OHG-COMM50-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete/Block Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-F06-S
(CAD/BIM Typicals)
English
-
Common Construction Joints Firestop Schedule
(Specification Text)
English
-
CAD Details (PDF) for Piping Supports, MQ Details
(CAD/BIM Typicals)
English
-
Product Data Sheet for CB-G MG Multipurpose Grout
(Technical information / Product data sheet)
French
-
CAD Detail (PDF) TD-P-TP01-S
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Low Voltage Penetrations Through Concrete Floor, Concrete Wall, or Block Wall, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EQP-51-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete Over Metal Deck, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-BC52-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-BC52-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Equipment Supports, MI Library
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Concrete Over Metal Deck, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Low Voltage Penetrations Through Concrete Floor, Concrete Wall, or Block Wall, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TR03-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-F06-C
(CAD/BIM Typicals)
English
-
Common Through Penetrations Firestop Schedule
(Specification Text)
English
-
Product Data Sheet for CB-G MG Multipurpose Grout
(Technical information / Product data sheet)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete Over Metal Deck, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-GP04-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-GP54-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete Floor, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Cable Tray Supports, MI Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-C55-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TR53-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
Product Data Sheet for Shower and Floor Drain
(Technical information / Product data sheet)
English
-
CAD Details (DWG) for Electrical Penetrations Through Concrete/Block Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TR53-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Integrated Floor Systems, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-BC02-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-C05-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete Floor, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EQP-03-C
(CAD/BIM Typicals)
English
-
Customer Flyer for PR 2-HS Rotating Laser
(Brochure)
-
CAD Details (DWG) for Low Voltage Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-GP54-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Platforms, MI Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-F16-S
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete Over Metal Deck, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) OHG-COMM52-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) OHG-COMM51-S
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete/Block Wall, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-F06-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Piping Supports, MI Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TP51-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Low Voltage Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) EQP-01-NA
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete Over Metal Deck, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-BC52-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-BC52-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical and Instrumentation Stands, MQ Library
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Concrete Floor, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Low Voltage Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TP51-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-F06-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete/Block Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-GP04-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TP01-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete Floor, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Cable Tray Supports, MQ Details
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-C55-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TR53-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
Product Data Sheet for CB-G PG Precision Grout
(Technical information / Product data sheet)
French
-
CAD Details (DWG) for Electrical Penetrations Through Concrete/Block Wall, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TR03-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Overhead Grid Systems, MI Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-C55-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
Customer Flyer for PR 2-HS Rotating Laser
(Brochure)
-
CAD Detail (PDF) EQP-02-NA
(CAD/BIM Typicals)
English
-
Customer Flyer for PR 30-HVS Rotating Laser
(Brochure)
-
CAD Detail (PDF) PL-SA03-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-GP54-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Platforms, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-GP04-C
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete Floor, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) PL-BC50-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) IFS-FT51-C
(CAD/BIM Typicals)
English
-
Product Data Sheet for CB-G PG Precision Grout
(Technical information / Product data sheet)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-Complete Set
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Piping Supports, MI Details
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TP51-S
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete/Block Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-BC02-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-C05-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical and Instrumentation Stands, MI Library
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Concrete Floor, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Low Voltage Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TP51-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-F16-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations Through Concrete/Block Wall, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-F16-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-TP01-S
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Mechanical Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations, 1, 2 or 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Cable Tray Supports, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-CT-C05-S
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-BC02-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Electrical Penetrations Through Concrete/Block Wall, 3 Hour
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Electrical Penetrations Through Gypsum Wall, 1 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-TR03-C
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Overhead Grid Systems, MQ Library
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-C55-S
(CAD/BIM Typicals)
English
-
Customer Flyer for PR 30-HVS Rotating Laser
(Brochure)
-
CAD Details (DWG) for Mechanical Penetrations Through Gypsum Wall, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) IFS-EQP50-C
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) PL-BC01-NA
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Mechanical Penetrations Through Concrete Floor, 2 Hour
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) TD-P-GP04-S
(CAD/BIM Typicals)
English
-
Commercial Building Metal deck & Bar Joist (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Installation Troubleshooting Guide for CFP-SP WB Fire Finish
(Reference document)
Detailed installation troubleshooting guide for CFP-SP WB fire finish.
English
-
Residential Wood (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
CAD Details (DWG) for Top and Bottom-of-Wall Joint for Flat Deck, 2 Hour
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Commercial Building Metal deck (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Residential Building Flat deck (CA-EN)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Top-of-Wall Joint for Concrete Over Metal Deck, 2 Hour
(CAD/BIM Typicals)
English
-
Residential Building Hollow Core (CA-EN)
(CAD/BIM Typicals)
English
-
Commercial Building Metal deck (CA-EN)
(CAD/BIM Typicals)
English
-
Healthcare Building Metal deck (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Residential Building Hollow Core (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Healthcare Building Metal deck (CA-EN)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for Top and Bottom-of-Wall Joint for Flat Deck, 2 Hour
(CAD/BIM Typicals)
English
-
Common Through Penetrations Firestop Schedule
(Specification Text)
English
-
Residential Wood (CA-EN)
(CAD/BIM Typicals)
English
-
Common Construction Joints Firestop Schedule (Excel)
(Specification Text)
English
-
Commercial Building Metal deck & Bar Joist (CA-EN)
(CAD/BIM Typicals)
English
-
UL Listing (CA-EN) for HCI-WF/MD, HDI, HDV, Kwik Bolt 3, Kwik Bolt-TZ, and KBV for Pipe Hangers
(Approval document / FM (Factory Mutual))
English
-
Residential Building Flat deck (CA-EN)
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Hilti Certificate 2.2 2008565 8.8 AM8X3000
(Inspection document / 2.2 Inspection document)
English
-
Hilti Certificate 2.2 333157 5.8 HAS-E-F M16X125 348
(Inspection document / 2.2 Inspection document)
English
-
Hilti Certificate 2.2 387070 5.8 HIT-V M20X380
(Inspection document / 2.2 Inspection document)
English
English
-
Hilti Certificate 2.2 407495 8.8 AM6X1000
(Inspection document / 2.2 Inspection document)
English
English
-
Hilti Certificate 2.2 409556 5.8 HIT-V-F M12X120
(Inspection document / 2.2 Inspection document)
English
English
-
Technical Manual for ETA-13/0516 for CFS-T cable transit system for penetrations
(Technical information / ETA)
Technical Manual for ETA-13/0516 for CFS-T cable transit system for penetrations issued by Hilti in 07/2013
English
-
VOC_SCAQMD and EPA24_CFS-F SOL_EN
(HSE Information / LEED / VOC)
VOC_SCAQMD and EPA24_CFS-F SOL_EN
English
-
VOC_Test_Report_CDPH_HIT-RE 500 V3_EN
(HSE Information)
VOC_Test_Report_CDPH_HIT-RE 500 V3_EN
English
-
VOC_AgBB_HIT-RE 100_EN
(HSE Information)
VOC_AgBB_HIT-RE 100_EN
English
-
VOC_AgBB_HIT-RE 10_EN
(HSE Information)
VOC_AgBB_HIT-RE 10_EN
English
-
VOC_AgBB_HIT-RE 500 V3 _EN
(HSE Information)
VOC_AgBB_HIT-RE 500 V3 _EN
English
-
VOC_French Label_HIT-RE 100_EN
(HSE Information)
VOC_French Label_HIT-RE 100_EN
English
-
VOC_French Label_HVU 2_EN
(HSE Information)
VOC_French Label_HVU 2_EN
English
-
EPD_HIT-HY 200-A_EN
(HSE Information)
EPD_HIT-HY 200-A_EN
English
-
Technical data HAC-30 with MQM wing nut
(Technical information / Technical Information)
Tech.Data of HAC-30 in combination w/ MQM wing nuts
English
-
Texte de spécification - HCS
(Specification Text)
French
-
CFS-EOS QS Application Guideline (CA-FR)
(Technical information / Operating Instruction)
French
-
Corrosion handbook
(Documentation)
Corrosion handbook
English
-
ETA_Modulare_Schienensysteme_V1.4_de
(Approval document / ETA)
ETA
German
-
HCS White Paper on Maturity Method (French)
(Brochure)
White Paper on Maturity Method (FR)
-
CAD Details (PDF) for MEP Anchor Supports
(CAD/BIM Typicals)
-
CAD Details (DWG) for MEP Anchor Supports
(CAD/BIM Typicals)
-
CAD Details (DWG) for Post-Installed Adhesive Anchors
(CAD/BIM Typicals / Auto CAD drawing file)
Typical details and general notes for post-installed adhesive anchors.
English
-
CAD Details (DWG) for Post-Installed Mechanical Anchors
(CAD/BIM Typicals / Auto CAD drawing file)
Typical details and general notes for post-installed mechanical anchors.
English
-
Confirmation_LEED_V4.1_HIT-RE 500 V3_102020
(HSE Information)
English
-
Confirmation_LEED_V4_HIT-RE 100_112015
(HSE Information)
English
-
Confirmation_LEED_V4_HIT-RE 10_102017
(HSE Information)
English
-
Confirmation_LEED_V4_HVU 2_032017
(HSE Information)
English
-
Confirmation_LEED_HVU-TZ_LEED_062009
(HSE Information)
English
-
Anchor Selector Chart
(Brochure)
-
ULc_E505298_X-MW-ALH27_X-MW-ALH32_Cables-Conduits_2021-06-09_en
(Approval document)
English
-
UL-CAN_E505298_X-MW-ALH27_X-MW-ALH32_Cables-Conduits_2021-06-09_en
(Approval document / UL (Underwriter Laboratories))
UL approval for Hilti X-MW-ALH27, X-MW-ALH32 fastener for fastening of cables and conduits, delivered by UL on June 9, 2021
English
-
UL_E517614_X-MW-ALH27_X-MW-ALH32_X-MW-MX_Luminaire-Fittings_2021-06-09_en
(Approval document)
English
-
UL-Can_E517614_X-MW-ALH27_X-MW-ALH32_X-MW-MX_Luminaire-Fittings_2021-06-09_en
(Approval document)
English
-
Installation Guide for CP 617 Firestop Putty Pads_SP
(Reference document / Operating Instruction)
Detailed installation instructions for the CP 617 Firestop Putty Pad
Spanish
-
Installation Guide for CP 617 Firestop Putty Pads_ENG
(Reference document / Operating Instruction)
Detailed installation instructions for the CP 617 Firestop Putty Pad
English
-
Installation Guide for CP 617 Firestop Putty Pads_FR_CA
(Reference document / Operating Instruction)
Detailed installation instructions for the CP 617 Firestop Putty Pad
French
-
X-DFB, X-EMTC Data Sheet
(Technical information)
English
-
X-EAS-FE MX Data Sheet
(Technical information)
English
-
X-FB Data Sheet
(Technical information)
English
-
Platform Typicals
(CAD/BIM Typicals)
-
X-W6-12-14 B3 Performance Letter
(Technical information / Technical Information)
English
-
LEEDv4.1 (CDPH) Emissions Report_CFS-COS
(Schematic / LEED)
-
UL listing Hilti AG Sprinkler
(Approval document / UL (Underwriter Laboratories))
UL approved EX15279
English
-
Technical Bulletin for HIT-RE 500 V3 with large annular gap
(Technical information / Technical Information)
English
-
CAD Details (DWG) for HAC-40 EDGE Lite
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC-50 EDGE Lite also includes HAC-T50 EDGE Lite details (serrated channel profile)
(CAD/BIM Typicals)
English
-
CAD Details for HAC-50 EDGE includes HAC-50 EDGE (EDGE C, S EDGE, & S EDGE C)
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC CRFoS U - Rebar Face of Slab includes HAC-50, HAC-60, and HAC-70 channel profiles
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC-30
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC-T50 EDGE Lite Also includes HAC-50 EDGE Lite details (smooth channel profile)
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HBC-B to be used with HAC-30 anchor channels
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HBC-C and HBC-C-N to be used with HAC-40, HAC-50, HAC-60, and HAC-70 (smooth channels profiles)
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HBC-T (Serrated T-bolts) to be used with HAC-T50, HAC-T70 and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC Includes HAC-40, HAC-50, HAC-60, and HAC-70 channel profiles
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC-40 EDGE Lite
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC-50 EDGE Lite also includes HAC-T50 EDGE Lite details (serrated channel profile)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC-50 EDGE includes HAC-50 EDGE (EDGE C, S EDGE, & S EDGE C)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC CRFoS U - Rebar Face of Slab includes HAC-50, HAC-60, and HAC-70 channel profiles
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC-30
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HAC-T50 EDGE Lite Also includes HAC-50 EDGE Lite details (smooth channel profile)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) (CA-EN) for MEP Anchor Supports
(CAD/BIM Typicals)
English
-
CAD Details (DWG) (CA-EN) for MEP Anchor Supports
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HBC-B to be used with HAC-30 anchor channels
(CAD/BIM Typicals)
English
-
CAD Detail (PDF) for HBC-C and HBC-C-N to be used with HAC-40, HAC-50, HAC-60, and HAC-70 (smooth channels profiles)
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC Includes HAC-40, HAC-50, HAC-60, and HAC-70 channel profiles
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for HAC-T (serrated Channel) Includes HAC-T50, HAC-T70, and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)
(CAD/BIM Typicals)
English
-
CAD Details (PDF) for HBC-T (Serrated T-bolts) to be used with HAC-T50, HAC-T70 and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)
(CAD/BIM Typicals)
English
-
Abrasives Selector Card
(Brochure)
-
CAD Details (Simplified) (CA-EN) (PDF) for Smoke and Acoustic Penetrations and Joints
(CAD/BIM Typicals)
English
-
CAD Details (Simplified) (CA-EN) (PDF) for Joints
(CAD/BIM Typicals)
English
-
CAD Details (Simplified) (CA-EN) (PDF) for Floor Penetrations
(CAD/BIM Typicals)
English
-
CAD Details (Simplified) (CA-EN) (DWG) for Joints
(CAD/BIM Typicals)
English
-
CAD Details (Simplified) (CA-EN) (DWG) for Floor Penetrations
(CAD/BIM Typicals)
English
-
CAD Details (Simplified) (CA-EN) (PDF) for Wall Penetrations
(CAD/BIM Typicals)
English
-
ACI-349 Approval for KB-TZ2 Expansion Anchor
(Technical information / ACI)
English
-
CFS-TTS Field Acoustical Field Testing Report
(Test Report / Test Report)
English
-
Product Technical Guide Supplement for HRD-H Plastic Frame Anchor, English
(Technical information)
English
-
ABS Approval 21-2146145-PDA for stainless steel powder-actuated X-CR, X-R and X-ST fasteners
(Approval document / ABS)
American Bureau of Shipping Approval for general purpose fasteners X-CR and X-R and threaded studs X-ST, delivered by ABS on August 2, 2021
English
-
LEED Information for Drywall Screws
(Documentation / LEED)
English
-
Approval Document
(Approval document)
-
VOC_AgBB_CP648_EN
(HSE Information / VOC)
Certificate_VOC AgBB/DIBt for CP 648 firestop wrap strip for penetrations delivered by Eurofins on 28.12.2010
English
-
LEED Information for HVU2 Injectable Mortar
(Documentation / LEED)
English
-
Productivity Component Wall Chart
(Brochure / No approval)
-
LEED Information for Hilti GX and BX Nails
(Documentation / LEED)
English
-
Product Technical Guide Supplement for HRD-H Plastic Frame Anchor, French
(Technical information)
English
-
California Proposition 65 Warning CFS-T
(Approval document)
English
-
X-CR Fasteners - LEED Information
(Documentation)
English
-
Product Data Sheet (US_CA_ENG) for CP 660 Firestop Foam
(Technical information / Product data sheet)
English
-
Product Technical Guide Supplement for Kwik HUS-EZ I and E Screw Anchors
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for KWIK-CON+ Concrete and Masonry Screw
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for HLC Sleeve Anchor
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for Cast-In Anchors KCS-WF
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for HDI-P Flush Anchors
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for HDI+, HDI-L+, HDI and HDI-S Flush Anchors
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for HVU2 Adhesive Capsule System
(Technical information / Technical Information)
English
-
Product Features & Technical Data - Strut Beam Clamp MQT-U
(Approval document)
-
MT Slider Plate Mechanical Properties Technical Statement
(Reference document / Product data sheet)
-
MT Long Goods LEED Information
(Submittal / LEED)
English
-
Substitution Letter for HSL-3 to HSL4
(Documentation)
English
-
Instructions for use_HUD-2
(Documentation)
English
-
Substitution Letter for KB-TZ to KB-TZ2
(Technical information / Technical Information)
-
Substitution Letter for KB3 CS to KB1 CS
(Technical information / Technical Information)
-
Substitution Letter for KB-TZ to KB1
(Technical information / Technical Information)
-
Substitution Letter for KB3 to KB-TZ2
(Technical information / Technical Information)
-
UL 1598_Luminaire_MW imperial
(Approval document / Approval)
-
UL 2239 Conduit and cable_MW imperial
(Approval document / Approval)
-
Confirmation_LEED_4.1_HIT-HY-200-A V3_EN
(HSE Information / LEED)
English
-
ICC ESR-4006 for Kwik Cast KCS-WF/MD Headed Cast-In Specialty Inserts in Cracked and Uncracked Concrete
(Approval document / ICC-ESR)
Headed cast-in specialty insert used to resist static, wind and seismic tension and shear loads in cracked and uncracked concrete; IBC 2015 compliant.
English
-
Product Technical Guide Supplement (CA-FR) for HVU2 Adhesive Capsule System
(Technical information / Technical Information)
French
-
CAD Details (PDF) for Non-Fire Rated Smoke Partition CS-S SA Light Smoke and Acousitic Sealant
(CAD/BIM Typicals)
English
-
CAD Details (DWG) for Non-Fire Rated Smoke Partitions CS-S SA LIGHT Smoke and Acoustic Sealant
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Hilti BX 3-SCT Test instructions_December 2021
(Technical information)
Hilti BX 3-SCT Test instructions_12-2021
English
-
CAD Details (DWG) for various penetrations with CPF-ES ENDO-SHIELD
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
Pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD
French
-
Pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal for T-Ratings using HILTI CFP-ES ENDO-SHIELD
English
-
Product Data Sheet for CFP-ES ENDO-SHIELD
(Technical information / Product data sheet)
French
-
Pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal for penetrants wrapped in HILTI CFP-ES ENDO-SHIELD
English
-
Pre-build submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD
English
-
Pre-built submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal large metallic boxes treated with HILTI CFP-ES ENDO SHIELD
French
-
Pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD
(Approval document / Approval)
pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD
French
-
LEEDv4.1 (CDPH) Emissions Report_CFP-ES ENDO-SHIELD
(Schematic / LEED)
English
-
CAD Details (PDF) for various penetrations with CFP-ES ENDO-SHIELD
(CAD/BIM Typicals)
English
-
Technical Manual for ETA-10/0109 CFS-F FX firestop foam for penetrations
(Technical information)
Technical Manual for ETA-10/0109 CFS-F FX Firestop Foam
English
-
ETA-12/0084 HIT-HY-200-R Anchor EC2 & TR055 50 years
(Approval document / Seismic / ETA)
ETA 12/0084 for HIT-HY 200-R injection mortar and standard anchor rods for anchoring in cracked and uncracked concrete and seismic C1, issued by DIBt on 14/04/2015
English, German
-
CoCP 2873-CPR-201-66 HIT-RE 500 V4 anchor for ETA 20-0541
(Certificate)
CoCP_2873-CPR-201-66_01.04.2021_HIT-RE 500 V4 anchor for ETA-20-0541_21.11.2020
English, French, German
-
Spec Section 2X 05 29 for Cable Hanging System (CA-FR)
(Specification Text)
French
-
Product Data Sheet for CFS-TTS MD P & CFS-TTS MD C (CA-FR)
(Technical information / Product data sheet)
French
-
SMACNA Test & Verification Report for X-MW Wire Hanger System
(Certificate / UL (Underwriter Laboratories))
English
-
Anchor Channel Design Guide
(Technical information / Technical Information)
Design Guide for Hilti Anchor Channels
English
-
Technical Datasheet HAC-C-P Anchor Channels
(Technical information / Technical Information)
Technical Datasheet HAC-C-P Anchor Channels
English
-
CoCP 2873-CPR-201-56 HIT-HY 200-A / R V3 for ETA 19-0601
(Certificate)
English, German
-
Electrical continuity test for MT Modular Support System_XE-21-48
(Certificate / Certificate of Conformity)
CoC for MT Modular Support System to IEC/ EN 61537
English
-
Wire Hanger System Portfolio
(Brochure)
-
ICC ESR-3963 for HIT-HY 200 Adhesive Anchors in Masonry
(Approval document / ICC-ESR)
Adhesive anchoring system to resist static, wind and seismic loads in fully grouted concrete and masonry walls in accordance with IBC 2015.
English
-
Substitution letter HY 200 V3 (CA-EN)
(Documentation / Technical Information)
English
-
Wire Hanger System MW - Technical Guide
(Technical information / Technical Information)
English
-
Product Technical Guide Supplement for Seismic Bracing per NFPA January 2022
(Technical information / Technical Information)
English
-
Fiche technique du produit pour CP 619T
(Technical information / Product data sheet)
French
-
DOC CE Hilti PP EY-GU grey
(Certificate / Declaration of Conformity)
Declaration of Conformity for PP EY-GU tinted grey
English
-
Acoustics Performance Test Report for Joint CS-S-SA Light, No. TL20-402
(Technical information / Test Report)
English
-
HI/PF 120-07
(CAD/BIM Typicals / Auto CAD drawing file)
HVAC line set through Mass Timber Floor or Wall
English
-
HI/PF 120-10
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 6" steel, or Iron Pipe with max 2" glass fiber through Mass Timber Floor or Wall.
English
-
DOC CE Hilti PP EY-GU blue
(Certificate / Declaration of Conformity)
Declaration of Conformity for PP EY-GU tinted blue
English
-
FW-D-0042
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=2")
English
-
FW-D-0101
(Firestop System Details / UL Detail Drawing)
English
-
Powder-actuated fasteners and fastening screws in steel construction, Reprint from Stahlbau-Kalender 2019, Ernst & Sohn
(Reference document)
English
-
ABS Type Approval 21-2140400-PDA for S-BT fastening system in off-shore and shipbuilding application
(Approval document / ABS)
American Bureau of Shipping Approval for S-BT screw-in stainless steel and carbon steel threaded fasteners, delivered by ABS on August 1, 2021
English
-
HI/PF 120-10
(Approval document / Penetration)
Nominal 6" steel, or Iron pipe insulated with Max 2" glass fiber through Mass Timber Floor or Wall
English
-
HI/PF 120-08
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through Mass Timber Floor or Wall.
English
-
Electrical continuity test for Grating Fastening Solutions_XE-21-47
(Certificate / Certificate of Conformity)
CoC for Grating Fastening Solutions according to IEC/ EN 61537
English
-
DOC CE Hilti PP EY-CA
(Certificate / Declaration of Conformity)
Declaration of Conformity for PP EY-CA
English
-
DOC CE Hilti PP EY-HAS
(Certificate / Declaration of Conformity)
Declaration of Conformity for PP EY-HA S
English
-
DIBT_Z-21.8-2137_HUS4_reusability_122021_de
(Approval document / aBG)
German
-
WW-D-0270
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Optional one side installation) (Max. JW=2")
English
-
Acoustics Performance Test Report for Penetration CS-S-SA Light, No. TL20-406
(Technical information / Test Report)
English
-
Electrical continuity test for Threaded Studs_XE-21-50
(Certificate / Certificate of Conformity)
CoC for Threaded Studs according to IEC/ EN 61537
English
-
HI/PF 120-07
(Approval document / Penetration)
HVAC Line Set through Mass Timber Floor or Wall.
English
-
Technical Manual for ETA-10/0292 and 10/0389 for CFS-ACR firestop acrylate sealant for penetrations
(Technical information / ETA)
Technical Manual for ETA-10/0292 and 10/0389 for CFS-ACR firestop acrylate sealant for penetrations issued by Hilti in 12/2021
English
-
HW-D-0929
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")
English
-
FF-D-0155
(Firestop System Details / UL Detail Drawing)
English
-
WW-D-0269
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete or block wall Using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")
English
-
ASSET_DOC_LOC_16907462
(Brochure)
-
DOC CE Hilti PP EY-GU red
(Certificate / Declaration of Conformity)
Declaration of Conformity for PP EY-GU red
English
-
HI/PF 120-09
(Approval document / Penetration)
Max. 2" PVC (Sch. 40) (Vented) through Mass Timber Floor or Wall
English
-
HI/PF 120-11
(Approval document / Penetration)
Nominal 6" steel, iron, copper, steel conduit, or emt (AS = min. 1/2" to max. 1-7/16") through Mass Timber Floor or Wall.
English
-
FF-D-0055
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
LR Type Approval LR21394055TA for S-BT fastening system in off-shore, shipbuilding and industrial application
(Approval document / Lloyds)
Lloyd's Register Type Approval for S-BT screw-in stainless steel and carbon steel threaded fasteners and X-FCM-M, X-FCM-NG, X-FCM-R, X-FCM-R NG, X-FCS-R grating fasteners, delivered by LR on October 15, 2021
English
-
RINA Type Approval FPE278318CS/001 for S-BT-MR / -MF, S-BT-GR / -GF, S-BT-ER / -EF, X-FCM-R (NG), X-FCM-M (NG) and X-FCS-R fastening system in off-shore and shipbuilding application
(Approval document)
RINA Type Approval for screw-in stainless steel and carbon steel threaded fasteners S-BT-MR / -MF, S-BT-GR / -GF, electrical connectors S-BT-ER / -EF, grating fasteners X-FCM-R (NG), X-FCM-M (NG) and X-FCS-R, delivered by RINA on June 22, 2021.
English
-
HW-D-0930
(Firestop System Details / UL Detail Drawing)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")
English
-
HI/PF 120-09
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 2" PVC (Sch. 40) Vented through Mass Timber Floor or Wall.
English
-
HI/PF 120-11
(CAD/BIM Typicals / Auto CAD drawing file)
Nominal 6" steel, iron, copper, steel conduit, or emt (AS = min. 1/2" to max. 1-7/16") through Mass Timber Floor or Wall.
English
-
DOC CE Hilti PP EY_HAR
(Certificate / Declaration of Conformity)
English
-
ETA 17/0336 for HAC-C(-P) anchor channels with channel bolts (HBC)
(Approval document / ETA)
ETA 17/0336 for HAC-C(-P) anchor channels with channel bolts (HBC) delivered by DiBT
German
-
DRS Selector Chart (EN)
(Brochure)
-
HI/PF 120-08
(Approval document / Penetration)
Cable bundle (various cables) through Mass Timber Floor or Wall
English
-
Electrical continuity test for Oglaend Mekano Modular Support System_XE-21-49
(Certificate / Certificate of Conformity)
CoC for Oglaend Mekano Modular Support System according to IEC/ EN 61537
English
-
FW-D-1013
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
HW-D-0634
(Firestop System Details / UL Detail Drawing)
Gypsum Wall to bottom of offset I beam with Z-bar extensions (Max. JW=1-1/2")
English
-
HW-D-0654
(Approval document / Joint)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")
English
-
HW-D-0286
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
HW-D-0209
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")
English
-
CW-D-2025
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated Tilt-up Concrete Panel Curtain Wall (Max. JW=8")
English
-
HI/BP 120-08 (CEJ 259P)
(Approval document / Joint)
Gypsum with EIFS Finish and Steel Framing (Max. JW=8")
English
-
HI/PHV 120-07 (CEJ 261P)
(Approval document / Joint)
Gypsum with Stone Finish and Steel Framing (Max. JW=8")
English
-
HW-D-0296
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")
English
-
FF-D-1039
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
HW-D-0540
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")
English
-
HW-D-1011
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")
English
-
HI/BP 105-02 (CEJ 310P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8")
English
-
HI/BP 180-01 (CEJ 307P)
(Approval document / Joint)
Glass or Aluminum Spandrel with Aluminum Framing (Max. JW=8")
English
-
BW-S-0023
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete floor (bottom of wall)
English
-
HW-D-0403
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
FW-D-1012
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=3-3/4")
English
-
HW-D-1002
(Approval document / Joint)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
HW-D-1001
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
HI/BP 165-02 (CEJ 315P)
(Approval document / Joint)
Gypsum with Cementitious Finish and Steel Framing (Max. JW=6")
English
-
BW-S-0023
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall to concrete floor (bottom of wall)
English
-
FF-D-1001
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to concrete floor (floor to floor)
English
-
HI/BP 135-01 (CEJ 245P)
(Approval document / Joint)
Concrete Panels with Steel Framing (Max. JW=8")
English
-
FW-D-1021
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=3")
English
-
HI/BP 60-01 (CEJ 526P)
(Approval document / Joint)
Glass Spandrel with Aluminum Framing (vision glass at floor) (Max. JW=6")
English
-
FF-D-1012
(Approval document / Joint)
Concrete floor to floor joint
English
-
FW-D-1046
(Approval document / Joint)
Concrete stair case to Concrete wall joint (Max. JW=3-1/2")
English
-
HI/BP 180-02 (CEJ 308P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8")
English
-
HW-D-1008
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")
English
-
FF-D-1087
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint (Max. JW=3")
English
-
HW-D-0294
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (perpendicular) (Max. JW=1")
English
-
HW-D-0225
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")
English
-
HW-D-0636
(Firestop System Details / UL Detail Drawing)
Gypsum Shaft Wall to bottom of offset I beam with Z-bar extensions (Max. JW=1-1/2")
English
-
HW-D-0516
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")
English
-
FF-D-1026
(Approval document / Joint)
Concrete floor to floor joint
English
-
CW-D-2025
(Approval document / Joint)
Insulated Tilt-up Concrete Panel Curtain Wall (Max. JW=8")
English
-
HW-D-0184
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
CW-D-1015
(CAD/BIM Typicals / Auto CAD drawing file)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=4")
English
-
FF-D-1013
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
HI/BP 165-02 (CEJ 315P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Cementitious Finish and Steel Framing (Max. JW=6")
English
-
HW-D-0225
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")
English
-
BW-S-0001
(Firestop System Details / UL Detail Drawing)
Gypsum wall to Concrete floor (bottom-of-wall)
English
-
HW-D-0460
(Firestop System Details / UL Detail Drawing)
Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)
English
-
FW-D-0042
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=2")
English
-
HW-D-1011
(Approval document / Joint)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")
English
-
FF-D-1047
(Approval document / Joint)
Concrete floor to floor joint
English
-
FW-D-1001
(Approval document / Joint)
Concrete floor to concrete wall joint (Max. JW=6")
English
-
CW-S-2031
(Approval document / Joint)
Granite Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-1003
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")
English
-
BW-S-0001
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to Concrete floor (bottom-of-wall)
English
-
FW-D-1043
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete stair case to Concrete wall joint (Max. JW=3-3/4")
English
-
HW-D-0342
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete floor (Max. JW=1")
English
-
CW-D-1018
(Approval document / Joint)
Tilt-up Concrete Panel Curtain Wall (Max. JW=3")
English
-
HW-D-0181
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")
English
-
HI/PHV 120-11 (CEJ 265P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")
English
-
HW-D-0654
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")
English
-
HI/JS 120-05 (CEJ 127P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Aluminum Framing (Max JW = 6")
English
-
CW-S-2032
(Approval document / Joint)
Granite Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0286
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
CW-S-1007
(CAD/BIM Typicals / Auto CAD drawing file)
Tilt-Up Concrete Panel Curtain Wall (Max JW = 6")
English
-
FF-D-1087
(Approval document / Joint)
Concrete floor to floor joint (Max. JW=3")
English
-
HW-D-0687
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top of wall) (parallel)(cantilevered runner) (Max. JW=1-1/2")
English
-
HW-D-0258
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")
English
-
HW-D-1001
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
HW-D-0570
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (top-of-wall) (parallel) (Max. JW=1-1/2")
English
-
HW-D-0155
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
FF-D-1011
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
HW-D-0529
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HI/JS 120-05 (CEJ 127P)
(Approval document / Joint)
Glass Spandrel Panel with Aluminum Framing (Max JW = 6")
English
-
HW-D-0528
(Approval document / Joint)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HW-D-0516
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")
English
-
FF-D-1087
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint (Max. JW=3")
English
-
HW-D-0120
(Approval document / Joint)
Gypsum shaft wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")
English
-
FW-D-1047
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=2")
English
-
FF-D-1013
(Approval document / Joint)
Concrete floor to floor joint
English
-
FW-D-1047
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=2")
English
-
HW-D-0313
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes and joint (top-of-wall) (Max. JW=3/4")
English
-
HI/BP 120-07 (CEJ 244P)
(Approval document / Joint)
Concrete Panels with Steel Framing (Max. JW=8")
English
-
FW-D-1071
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=3")
English
-
HI/PHV 120-09 (CEJ 263P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")
English
-
HI/BP 120-07 (CEJ 244P)
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete Panels with Steel Framing (Max. JW=8")
English
-
FW-D-1012
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=3-3/4")
English
-
HW-D-0268
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)
English
-
CW-S-2028
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0268
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)
English
-
HI/BP 120-04 (CEJ 425P)
(Approval document / Joint)
Gypsum wall with various facades. Steel framing starts and stops above and below floor (Nom. 2" cantilever)
English
-
HW-D-1002
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
HW-D-0285
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
FF-D-0055
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HW-D-0564
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Penetrations through flutes) (Max. JW=2")
English
-
HI/BP 165-01 (CEJ 314P)
(Approval document / Joint)
Gypsum with Brick Finish and Steel Framing (Max. JW=6")
English
-
FW-D-1012
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=3-3/4")
English
-
FF-D-0052
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
HW-D-0516
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")
English
-
HI/PHV 120-11 (CEJ 265P)
(Approval document / Joint)
Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")
English
-
HI/BP 120-04 (CEJ 425P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall with various facades. Steel framing starts and stops above and below floor (Nom. 2" cantilever)
English
-
HW-D-1008
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-0539
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor (top-of-wall) (Max. JW=1-1/2")
English
-
FF-D-1039
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HW-D-0292
(Approval document / Joint)
Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")
English
-
HI/PHV 120-06 (CEJ 260P)
(Approval document / Joint)
Gypsum with Stucco Finish and Steel Framing (Max. JW=8")
English
-
HI/JF 120-01
(Approval document / Joint)
Gypsum Wall to Fireproofed Column Vertical Joint (Max. JW = 1-1/2")
English
-
FW-D-1021
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=3")
English
-
CW-S-2027
(Approval document / Joint)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HI/BP 120-05
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with various facades. Steel framing starts and stops above and below floor (Max. JW=0") (Max. 2" cantilever)
English
-
HW-D-0295
(Firestop System Details / UL Detail Drawing)
Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")
English
-
HI/BP 150-01
(Approval document / Joint)
Glass spandrel with aluminum framing (vision glass at floor) (Max. JW=8")
English
-
CW-S-2053
(CAD/BIM Typicals / Auto CAD drawing file)
Insulated Tilt-up Panel Curtain Wall (Max. JW=6")
English
-
FW-D-1046
(Firestop System Details / UL Detail Drawing)
Concrete stair case to Concrete wall joint (Max. JW=3-1/2")
English
-
HI/PHV 120-07 (CEJ 261P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Stone Finish and Steel Framing (Max. JW=8")
English
-
HI/BP 120-01 (CEJ 246P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
FW-D-1021
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=3")
English
-
HI/BP 120-01 (CEJ 246P)
(Approval document / Joint)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HI/PHV 120-08 (CEJ 262P)
(Approval document / Joint)
Gypsum with Brick Finish and Steel Framing (Max. JW=8")
English
-
CW-S-2030
(CAD/BIM Typicals / Auto CAD drawing file)
Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0286
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
FF-D-1011
(Approval document / Joint)
Concrete floor to floor joint
English
-
FW-D-1043
(Approval document / Joint)
Concrete stair case to Concrete wall joint (Max. JW=3-3/4")
English
-
HI/BP 180-02 (CEJ 308P)
(Approval document / Joint)
Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8")
English
-
HW-D-0403
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
FF-D-1012
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HI/BP 165-03 (CEJ 316P)
(Approval document / Joint)
Gypsum with Plaster Finish and Steel Framing (Max. JW=6")
English
-
HW-D-0542
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (top-of-wall) (parallel) (Max. JW=3/4")
English
-
HW-D-0466
(Approval document / Joint)
Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)
English
-
CJ-D-0004
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to non-rated floor/roof deck
English
-
HW-D-0440
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. JW=2")
English
-
HI/JS 120-04 (CEJ 529P)
(Approval document / Joint)
Glass spandrel panel with aluminum framing (Max. JW=2") (25% vertical shear movement)
English
-
HW-D-0460
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)
English
-
BW-S-0023
(Approval document / Joint)
Gypsum shaft wall to concrete floor (bottom of wall)
English
-
HI/JS 120-04 (CEJ 529P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass spandrel panel with aluminum framing (Max. JW=2") (25% vertical shear movement)
English
-
CW-D-2026
(Approval document / Joint)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")
English
-
HW-D-0541
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4")
English
-
FF-D-1013
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HI/JF 120-01
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum Wall to Fireproofed Column Vertical Joint (Max. JW = 1-1/2")
English
-
HW-D-0292
(Firestop System Details / UL Detail Drawing)
Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")
English
-
FF-D-1039
(Approval document / Joint)
Concrete floor to floor joint
English
-
CW-S-2031
(CAD/BIM Typicals / Auto CAD drawing file)
Granite Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0258
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")
English
-
CW-S-2030
(Approval document / Joint)
Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
FW-D-1037
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=6")
English
-
CW-D-1003
(Approval document / Joint)
Tilt-up Concrete Panel Curtain Wall (Max. JW=6")
English
-
HI/BP 120-08 (CEJ 259P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with EIFS Finish and Steel Framing (Max. JW=8")
English
-
HI/PHV 120-06 (CEJ 260P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Stucco Finish and Steel Framing (Max. JW=8")
English
-
FW-D-1043
(Firestop System Details / UL Detail Drawing)
Concrete stair case to Concrete wall joint (Max. JW=3-3/4")
English
-
HW-D-0225
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")
English
-
CW-S-2032
(CAD/BIM Typicals / Auto CAD drawing file)
Granite Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HI/BP 150-01
(CAD/BIM Typicals / Auto CAD drawing file)
Glass spandrel with aluminum framing (vision glass at floor) (Max. JW=8")
English
-
CW-S-2053
(Approval document / Joint)
Insulated Tilt-up Panel Curtain Wall (Max. JW=6")
English
-
FW-D-0041
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=1/2")
English
-
FF-D-1026
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HW-D-0540
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")
English
-
HI/BP 60-01 (CEJ 526P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with Aluminum Framing (vision glass at floor) (Max. JW=6")
English
-
HW-D-0466
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)
English
-
HW-D-0403
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
HW-D-0545
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4")
English
-
FF-D-1011
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
FW-D-1001
(Firestop System Details / UL Detail Drawing)
Concrete floor to concrete wall joint (Max. JW=6")
English
-
HW-D-0529
(Approval document / Joint)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HW-D-0285
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
CW-S-2029
(CAD/BIM Typicals / Auto CAD drawing file)
Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0540
(Approval document / Joint)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")
English
-
FW-D-1013
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
HI/BP 135-01 (CEJ 245P)
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete Panels with Steel Framing (Max. JW=8")
English
-
HI/PHV 120-08 (CEJ 262P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Brick Finish and Steel Framing (Max. JW=8")
English
-
FW-D-1071
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=3")
English
-
FW-D-1047
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=2")
English
-
HW-D-0296
(Firestop System Details / UL Detail Drawing)
Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")
English
-
FW-D-1071
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=3")
English
-
HI/BPF 120-06 (CEJ 216P)
(Approval document / Joint)
Glass Spandrel Panel and Aluminum Framing (Max. JW=6")
English
-
CW-D-1015
(Approval document / Joint)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=4")
English
-
FF-D-0052
(Approval document / Joint)
Concrete floor to floor joint
English
-
FF-D-1047
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
HW-D-0538
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")
English
-
HI/BP 120-03 (CEJ 421P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall with various facades (Max. JW=9", including studs)
English
-
HW-D-0528
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HW-D-0296
(Approval document / Joint)
Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")
English
-
HW-D-0154
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HW-D-0268
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)
English
-
HW-D-0569
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")
English
-
FF-D-0052
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint
English
-
FW-D-1011
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
BW-S-0001
(Approval document / Joint)
Gypsum wall to Concrete floor (bottom-of-wall)
English
-
HW-D-1008
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-1009
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-3/4")
English
-
HI/BP 120-03 (CEJ 421P)
(Approval document / Joint)
Gypsum wall with various facades (Max. JW=9", including studs)
English
-
HW-D-0294
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (perpendicular) (Max. JW=1")
English
-
HW-D-0264
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (offset flutes) (Max. JW=1-1/2")
English
-
CW-S-2027
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0285
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")
English
-
FW-D-1011
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
HI/BPF 120-06 (CEJ 216P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel and Aluminum Framing (Max. JW=6")
English
-
HI/BP 105-02 (CEJ 310P)
(Approval document / Joint)
Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8")
English
-
HI/PHV 120-10 (CEJ 264P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with EIFS Finish and Steel Framing (Max. JW=8")
English
-
CW-S-2028
(Approval document / Joint)
Glass Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-0324
(Firestop System Details / UL Detail Drawing)
Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")
English
-
FW-D-1046
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete stair case to Concrete wall joint (Max. JW=3-1/2")
English
-
HI/PHV 120-10 (CEJ 264P)
(Approval document / Joint)
Gypsum with EIFS Finish and Steel Framing (Max. JW=8")
English
-
FF-D-1001
(Approval document / Joint)
Concrete floor to concrete floor (floor to floor)
English
-
FW-D-0041
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=1/2")
English
-
HW-D-0466
(Firestop System Details / UL Detail Drawing)
Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)
English
-
CW-D-2046
(Approval document / Joint)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")
English
-
FW-D-1037
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=6")
English
-
CW-S-1007
(Approval document / Joint)
Tilt-Up Concrete Panel Curtain Wall (Max JW = 6")
English
-
HI/BP 165-03 (CEJ 316P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Plaster Finish and Steel Framing (Max. JW=6")
English
-
FF-D-1001
(Firestop System Details / UL Detail Drawing)
Concrete floor to concrete floor (floor to floor)
English
-
HW-D-0530
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HI/BP 120-05
(Approval document / Joint)
Gypsum with various facades. Steel framing starts and stops above and below floor (Max. JW=0") (Max. 2" cantilever)
English
-
FF-D-1012
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
HW-D-0181
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")
English
-
CW-D-1003
(CAD/BIM Typicals / Auto CAD drawing file)
Tilt-up Concrete Panel Curtain Wall (Max. JW=6")
English
-
HW-D-0181
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")
English
-
HW-D-0440
(Approval document / Joint)
Concrete or block wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. JW=2")
English
-
HW-D-0571
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to bottom of fireproofed steel beam to concrete over metal deck (top-of-wall) (Max. JW=1-1/2")
English
-
HW-D-0460
(Approval document / Joint)
Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)
English
-
HI/PHV 120-09 (CEJ 263P)
(Approval document / Joint)
Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")
English
-
HI/BP 105-01 (CEJ 309P)
(Approval document / Joint)
Glass Spandrel with Aluminum Framing (Max. JW=8")
English
-
HW-D-0258
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")
English
-
CW-D-2046
(CAD/BIM Typicals / Auto CAD drawing file)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")
English
-
HW-D-0292
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")
English
-
FW-D-0041
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max. JW=1/2")
English
-
HW-D-1003
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")
English
-
HI/BP 180-01 (CEJ 307P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass or Aluminum Spandrel with Aluminum Framing (Max. JW=8")
English
-
HW-D-0046
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall)
English
-
FW-D-1037
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=6")
English
-
CJ-D-0004
(Approval document / Joint)
Gypsum wall to non-rated floor/roof deck
English
-
CW-S-2029
(Approval document / Joint)
Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")
English
-
HW-D-1002
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
HW-D-1001
(Approval document / UL Detail Drawing)
Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")
English
-
FW-D-1011
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
HI/BP 165-01 (CEJ 314P)
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum with Brick Finish and Steel Framing (Max. JW=6")
English
-
FF-D-1026
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
CW-D-1018
(CAD/BIM Typicals / Auto CAD drawing file)
Tilt-up Concrete Panel Curtain Wall (Max. JW=3")
English
-
FW-D-0042
(Approval document / Joint)
Concrete floor to wall joint (Max. JW=2")
English
-
HW-D-0190
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=2")
English
-
HW-D-0530
(Approval document / Joint)
Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")
English
-
HW-D-0635
(Firestop System Details / UL Detail Drawing)
Gypsum Wall to bottom of offset I beam with Z-bar extensions w/ additional gypsum (Max. JW=1-1/2")
English
-
CW-D-2026
(CAD/BIM Typicals / Auto CAD drawing file)
Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")
English
-
FF-D-1047
(Firestop System Details / UL Detail Drawing)
Concrete floor to floor joint
English
-
FF-D-0055
(Approval document / Joint)
Concrete floor to floor joint
English
-
HW-D-1009
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-3/4")
English
-
HI/BP 105-01 (CEJ 309P)
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with Aluminum Framing (Max. JW=8")
English
-
HW-D-0120
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")
English
-
HW-D-0396
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal roof deck (offset to flute) (Max. JW=3/4")
English
-
FW-D-1013
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max. JW=3-1/2")
English
-
HW-D-1003
(Approval document / Joint)
Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")
English
-
FW-D-1001
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to concrete wall joint (Max. JW=6")
English
-
CJ-D-0004
(Firestop System Details / UL Detail Drawing)
Gypsum wall to non-rated floor/roof deck
English
-
CW-D-1019
(Approval document / Joint)
Tilt-up Concrete Panel Curtain Wall (Max. JW=4")
English
-
J-CS-TTS SA
(Firestop System Details / UL Detail Drawing)
Joint system for non-rated smoke partitions with CS-TTS SA Smoke & Acoustic Track Seal
English
-
BW-S-0040
(Approval document / Joint)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
HW-D-0881
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
HW-D-1069
(Approval document / Joint)
Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-S-0055
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)
English
-
HW-D-1104
(CAD/BIM Typicals / Auto CAD drawing file)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
HW-D-0077
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")
English
-
HW-D-0119
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete over fluted metal deck or flat concrete (top-of-wall)
English
-
WW-D-0064
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-S-0053
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
FW-D-1092
(Firestop System Details / UL Detail Drawing)
Concrete floor to wall joint (Max JW=3”)
English
-
WW-D-0141
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=1”)
English
-
WW-D-0017
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=2")
English
-
HI/BPF 120-19
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=4-1/2")
English
-
HW-D-1104
(Approval document / Joint)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
HW-D-1070
(Firestop System Details / UL Detail Drawing)
Block wall to underside of flat concrete (Max. JW=2-1/2")
English
-
WW-D-1011
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
WW-D-0032
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)
English
-
FW-D-0066
(Approval document / Joint)
Concrete stair case to concrete wall joint (Max JW=2”)
English
-
HW-S-0090
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")
English
-
HI/BPF 120-22
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")
English
-
FF-D-0096
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint (Max JW = 2”)
English
-
HW-D-0061
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")
English
-
WW-S-0042
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)
English
-
HW-D-0883
(Approval document / Joint)
Gypsum shaft wall to bottom of fire-proofed steel beam (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
HW-S-0053
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
HI/BPF 120-17
(Approval document / Joint)
Glass Spandrel Panel with Aluminum Framing (Max JW = 4")
English
-
HW-D-1041
(Approval document / Joint)
Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-1020
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck (Max. JW=3")
English
-
HW-D-0702
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)
English
-
HW-D-0081
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HW-S-0069
(Approval document / Joint)
Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")
English
-
WW-D-0017
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-S-0055
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)
English
-
HI/BPF 120-17
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Aluminum Framing (Max JW = 4")
English
-
J-572/TP-572
(CAD/BIM Typicals / Auto CAD drawing file)
Joint details for non fire-rated smoke partitions with CP 572 Smoke & Acoustic Spray
English
-
HW-D-0703
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)
English
-
HW-D-1068
(Firestop System Details / UL Detail Drawing)
Gypsum wall to underside of flat concrete (Max. JW=2-1/2")
English
-
HW-D-1045
(Approval document / Joint)
Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-1044
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-1037
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-0097
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall)
English
-
HI/BPF 120-15
(Approval document / Joint)
Zero Spandrel (Alll Vision Glass) (Max. JW = 4")
English
-
WW-D-0141
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=1”)
English
-
HW-D-0076
(Approval document / Joint)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")
English
-
HW-S-0055
(Approval document / Joint)
Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)
English
-
FW-D-1093
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max JW=3”)
English
-
HW-D-1042
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
HW-D-0882
(Approval document / Joint)
Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
WW-S-0048
(Approval document / Joint)
Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")
English
-
WW-D-1080
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=3")
English
-
WW-D-0220
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
HW-D-1070
(CAD/BIM Typicals / Auto CAD drawing file)
Block wall to underside of flat concrete (Max. JW=2-1/2")
English
-
HW-D-1041
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-0083
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=3/4")
English
-
HW-D-0097
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall)
English
-
BW-S-0039
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
HI/BPF 120-21
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")
English
-
HW-S-0090
(Firestop System Details / UL Detail Drawing)
Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")
English
-
WW-D-0140
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=2”)
English
-
HW-S-0145
(Firestop System Details / UL Detail Drawing)
Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")
English
-
HI/BPF 120-16
(Approval document / Joint)
Zero spandrel (All Vision Glass) (Max. JW = 4")
English
-
WW-D-1128
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HW-D-0632
(Approval document / Joint)
Gypsum wall to flat concrete (top-of-wall) (Max. JW=1”)
English
-
HW-D-1066
(Firestop System Details / UL Detail Drawing)
Gypsum wall perpendicular to fluted metal deck (Max. JW=2-1/2")
English
-
HI/BPF 120-19
(Approval document / Joint)
Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=4-1/2")
English
-
WW-D-0105
(Approval document / Joint)
Gypsum wall to concrete/block wall joint (Max. JW=1") (Polyethylene Backer Rod)
English
-
FF-D-0096
(Approval document / Joint)
Concrete floor to floor joint (Max JW = 2”)
English
-
HI/BPF 120-16
(CAD/BIM Typicals / Auto CAD drawing file)
Zero Spandrel (Alll Vision Glass) (Max. JW = 4")
English
-
WW-S-0048
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")
English
-
WW-D-0032
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)
English
-
HW-D-0061
(Approval document / Joint)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")
English
-
FF-D-1125
(CAD/BIM Typicals / Auto CAD drawing file)
maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.
English
-
HW-S-0134
(Firestop System Details / UL Detail Drawing)
English
-
HW-D-1070
(Approval document / Joint)
Block wall to underside of flat concrete (Max. JW=2-1/2")
English
-
WW-S-0048
(Firestop System Details / UL Detail Drawing)
Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")
English
-
WW-D-1012
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max JW = 3-3/4")
English
-
HW-D-0081
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HW-D-1068
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to underside of flat concrete (Max. JW=2-1/2")
English
-
HW-D-1044
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
HW-S-0134
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
FW-D-0066
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HW-D-0085
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (includes Epic Metals deck) (top-of-wall) (Max. JW=3/4")
English
-
WW-D-0067
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to wall joint (Max JW = 2")
English
-
WW-D-1012
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max JW = 3-3/4")
English
-
HI/BPF 120-13
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Aluminum Framing (Max JW = 6")
English
-
HI/JF 120-03
(Approval document / Joint)
Gypsum Shaft Wall to Fireproofed Column Vertical Joint (Max. JW = 5/8")
English
-
HW-D-1068
(Approval document / Joint)
Gypsum wall to underside of flat concrete (Max. JW=2-1/2")
English
-
WW-D-1129
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=3”)
English
-
HI/BPF 120-23
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")
English
-
FW-D-0067
(Approval document / Joint)
Concrete floor to wall joint (Max JW=1”)
English
-
HW-D-1045
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
HI/BPF 120-18
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=5")
English
-
WW-D-1128
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=3”)
English
-
HW-D-0702
(Firestop System Details / UL Detail Drawing)
Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)
English
-
HW-D-0825
(Approval document / Joint)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
WW-D-1012
(Approval document / Joint)
Concrete wall to wall joint (Max JW = 3-3/4")
English
-
HW-D-1041
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")
English
-
FF-D-1126
(CAD/BIM Typicals / Auto CAD drawing file)
maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.
English
-
J-CS-TTS SA
(CAD/BIM Typicals / Auto CAD drawing file)
Joint system for non-rated smoke partitions with CS-TTS SA Smoke & Acoustic Track Seal
English
-
HI/BPF 120-23
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")
English
-
WW-D-1084
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
WW-D-0105
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete/block wall joint (Max. JW=1") (Polyethylene Backer Rod)
English
-
HW-D-0097
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall)
English
-
HW-D-1058
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor (Max. JW=3-1/4")
English
-
HW-D-0089
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck w/ optional use of spray-on fireproofing (top-of-wall) (Max. JW=2")
English
-
BW-S-0039
(Approval document / Joint)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
HW-D-0882
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
WW-D-0082
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=1")
English
-
WW-D-1080
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=3")
English
-
WW-D-1084
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
HW-D-0003
(Approval document / Joint)
Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
HW-D-0883
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HW-S-0090
(Approval document / Joint)
Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")
English
-
FF-D-0097
(Approval document / Penetration)
Concrete floor to floor joint (Max JW = 1”)
English
-
HW-D-1042
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
WW-D-0140
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=2”)
English
-
HW-D-0004
(Firestop System Details / UL Detail Drawing)
Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
HW-D-0704
(Firestop System Details / UL Detail Drawing)
English
-
HW-D-1058
(Approval document / Joint)
Concrete or block wall to concrete floor (Max. JW=3-1/4")
English
-
WW-D-0220
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
HW-D-1020
(Approval document / Joint)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck (Max. JW=3")
English
-
HW-D-1044
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
FF-D-1126
(Approval document / Joint)
maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.
English
-
HW-D-0881
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
CW-D-1019
(CAD/BIM Typicals / Auto CAD drawing file)
Tilt-up Concrete Panel Curtain Wall (Max. JW=4")
English
-
HI/JF 120-02
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum Wall-to-Fireproofed-Column Vertical Joint (Max. JW = 2-1/2")
English
-
HI/BPF 120-21
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")
English
-
WW-D-1047
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-S-0054
(Approval document / Joint)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
HW-D-0087
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck w/ optional use of spray-on fireproofing (top-of-wall) (Max. JW=2")
English
-
HW-D-1045
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")
English
-
HW-D-1067
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-D-0098
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (penetrations in flutes) (Max. JW=1")
English
-
HW-D-0881
(Approval document / Joint)
Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
WW-D-1011
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
WW-S-0042
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)
English
-
HW-D-0931
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")
English
-
WW-D-0067
(Approval document / Joint)
Gypsum wall to wall joint (Max JW = 2")
English
-
HW-D-0703
(CAD/BIM Typicals / Auto CAD drawing file)
English
-
HW-D-1037
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")
English
-
HI/BPF 120-20
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")
English
-
HW-D-0119
(Approval document / Joint)
Gypsum wall to concrete over fluted metal deck or flat concrete (top-of-wall)
English
-
HW-D-1104
(Firestop System Details / UL Detail Drawing)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
WW-D-1129
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=3”)
English
-
WW-S-0042
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)
English
-
HW-D-0704
(Approval document / Joint)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)
English
-
HW-D-0004
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
BW-S-0039
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
WW-D-0082
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=1")
English
-
HW-D-1058
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete floor (Max. JW=3-1/4")
English
-
FW-D-1093
(Approval document)
English
-
WW-D-0141
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=1”)
English
-
HI/BPF 120-14
(Approval document / Joint)
Zero Spandrel (All Vision Glass) (Max. JW = 4")
English
-
HW-S-0145
(Approval document / Joint)
Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")
English
-
HI/BPF 120-27
(CAD/BIM Typicals / Auto CAD drawing file)
Zero Spandrel (All Vision Glass) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4")
English
-
WW-D-1011
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
WW-D-0064
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-D-0084
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over metal deck (top-of-wall) (Max. JW=3/4")
English
-
FW-D-1092
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max JW=3”)
English
-
HW-D-1042
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")
English
-
HW-D-1069
(CAD/BIM Typicals / Auto CAD drawing file)
Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-D-1078
(Approval document / Joint)
Block wall to underside of flat concrete (Max. JW=3")
English
-
HW-D-0080
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HW-D-0825
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
WW-D-1047
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-D-0081
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
J-572
(Firestop System Details / UL Detail Drawing)
Joint details for non fire-rated smoke partitions with CP 572 Smoke & Acoustic Spray
English
-
FF-D-0097
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint (Max JW = 1”)
English
-
HW-D-1067
(Approval document / Joint)
Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-D-0118
(Approval document / Joint)
Gypsum wall to concrete over fluted metal deck (top-of-wall)
English
-
HI/BPF 120-14
(CAD/BIM Typicals / Auto CAD drawing file)
Zero Spandrel (All Vision Glass) (Max. JW = 4")
English
-
HI/BPF 120-10
(Approval document / Joint)
Zero Spandrel (All Vision Glass) (Max. JW = 4")
English
-
WW-D-1129
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=3”)
English
-
HW-D-0633
(Approval document / Joint)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular or parallel) (Max. JW=1")
English
-
HW-D-0931
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")
English
-
HI/BPF 120-09
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 6") (Static Joint)
English
-
HW-D-1067
(Firestop System Details / UL Detail Drawing)
Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-D-0702
(Approval document / Joint)
Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)
English
-
WW-D-0140
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=2”)
English
-
HI/BPF 120-15
(CAD/BIM Typicals / Auto CAD drawing file)
Zero Spandrel (Alll Vision Glass) (Max. JW = 4")
English
-
J-506/TP-506
(CAD/BIM Typicals / Auto CAD drawing file)
Joint details for non fire-rated smoke partitions with CP 506 Smoke & Acoustic Sealant or CP 605 Bottom-of-Wall Firestop Sealant
English
-
HW-S-0145
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")
English
-
WW-D-0220
(Approval document / Joint)
Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
HW-S-0069
(Firestop System Details / UL Detail Drawing)
Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")
English
-
WW-D-1047
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=2")
English
-
WW-D-0082
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=1")
English
-
WW-D-0032
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)
English
-
HW-D-0004
(Approval document / Joint)
Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
BW-S-0040
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
HW-D-0098
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (penetrations in flutes) (Max. JW=1")
English
-
HW-D-0082
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor (top-of-wall) (Max. JW=3/4")
English
-
HW-D-0633
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular or parallel) (Max. JW=1")
English
-
HW-D-1037
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")
English
-
HI/JF 120-03
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum Shaft Wall to Fireproofed Column Vertical Joint (Max. JW = 5/8")
English
-
HW-D-1078
(CAD/BIM Typicals / Auto CAD drawing file)
Block wall to underside of flat concrete (Max. JW=3")
English
-
HW-D-0076
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")
English
-
J-506-605
(Firestop System Details / UL Detail Drawing)
Joint details for non fire-rated smoke partitions with CP 506 Smoke & Acoustic Sealant or CP 605 Bottom-of-Wall Firestop Sealant
English
-
HI/BPF 120-27
(Approval document / Joint)
Zero Spandrel (All Vision Glass) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4")
English
-
WW-D-1084
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete wall to wall joint (Max. JW=3-1/2")
English
-
HW-D-0003
(Firestop System Details / UL Detail Drawing)
Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
HI/BPF 120-18
(Approval document / Joint)
Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=5")
English
-
FW-D-0067
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to wall joint (Max JW=1”)
English
-
WW-D-1080
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=3")
English
-
HI/BPF 120-13
(Approval document / Joint)
Glass Spandrel Panel with Aluminum Framing (Max JW = 6")
English
-
WW-D-1128
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=3”)
English
-
HI/BPF 120-22
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")
English
-
HW-D-1103
(CAD/BIM Typicals / Auto CAD drawing file)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
FW-D-1092
(Approval document / Joint)
Concrete floor to wall joint (Max JW=3”)
English
-
WW-D-0017
(Firestop System Details / UL Detail Drawing)
Concrete wall to wall joint (Max. JW=2")
English
-
BW-S-0040
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete floor (bottom-of-wall)
English
-
HW-D-1069
(Firestop System Details / UL Detail Drawing)
Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")
English
-
HW-D-1103
(Approval document / Joint)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
HW-D-0750
(Firestop System Details / UL Detail Drawing)
Gypsum shaft wall to concrete over metal deck (top-of-wall) (Max. JW=1-1/2")
English
-
HW-D-0703
(Firestop System Details / UL Detail Drawing)
English
-
HW-S-0054
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
HW-D-1012
(Approval document / Joint)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")
English
-
HW-D-0118
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete over fluted metal deck (top-of-wall)
English
-
HW-D-0080
(Firestop System Details / UL Detail Drawing)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HW-D-0704
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)
English
-
HW-D-1012
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")
English
-
HW-S-0054
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
HW-D-0080
(Approval document / Joint)
Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")
English
-
HI/JF 120-02
(Approval document / Joint)
Gypsum Wall-to-Fireproofed-Column Vertical Joint (Max. JW = 2-1/2")
English
-
HI/BPF 120-12
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 4")
English
-
HW-S-0053
(Approval document / Joint)
Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")
English
-
HW-D-0003
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")
English
-
HI/BPF 120-20
(CAD/BIM Typicals / Auto CAD drawing file)
Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")
English
-
WW-D-0220
(Approval document / Joint)
Concrete wall to wall joint (one-sided install) with optional max. 1" steel or pvc conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
HI/BPF 120-12
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 4")
English
-
HW-S-0069
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")
English
-
WW-D-0064
(Approval document / Joint)
Concrete wall to wall joint (Max. JW=2")
English
-
HW-D-0882
(CAD/BIM Typicals / Auto CAD drawing file)
Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")
English
-
HI/BPF 120-10
(CAD/BIM Typicals / Auto CAD drawing file)
Zero Spandrel (All Vision Glass) (Max. JW = 4")
English
-
HW-D-0076
(Firestop System Details / UL Detail Drawing)
Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")
English
-
FF-D-1125
(Approval document / Joint)
maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.
English
-
HW-S-0134
(Approval document / Joint)
English
-
HW-D-0825
(Firestop System Details / UL Detail Drawing)
Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")
English
-
HW-D-1078
(Firestop System Details / UL Detail Drawing)
Block wall to underside of flat concrete (Max. JW=3")
English
-
HW-D-1103
(Firestop System Details / UL Detail Drawing)
Block wall to underside of flat concrete or hollow core (Max. JW=3”)
English
-
HI/BPF 120-09
(Approval document / Joint)
Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 6") (Static Joint)
English
-
HI/BPF 120-31
(Approval document / Joint)
Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")
English
-
C-AJ-2021
(Approval document / Penetration)
Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)
English
-
C-AJ-5096
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")
English
-
C-AJ-5096
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")
English
-
HW-D-0929
(Approval document / Joint)
Concrete or block wall to concrete floor using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")
English
-
C-AJ-2024
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 2" PVC, CPVC, or Aquarise CPVC (knock-out sleeve)
English
-
C-AJ-3180
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-5185
(Approval document / Penetration)
Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")
English
-
C-AJ-3138
(Firestop System Details / UL Detail Drawing)
Single cable (telephone cable)
English
-
C-AJ-3298
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)
English
-
C-AJ-3138
(Approval document / Penetration)
Single cable (telephone cable)
English
-
C-AJ-5090
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel, copper pipe with max. 3/4" AB/PVC insulation (AS=1/2" to 2-1/4")
English
-
C-AJ-3138
(CAD/BIM Typicals / Auto CAD drawing file)
Single cable (telephone cable)
English
-
C-AJ-5277
(Approval document / Penetration)
Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete
English
-
C-AJ-3298
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)
English
-
C-AJ-4034
(Approval document / Penetration)
Cable Tray
English
-
WW-D-0269
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete or block wall to concrete or block wall Using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")
English
-
FF-D-1216
(CAD/BIM Typicals / Auto CAD drawing file)
Concrete floor to floor joint with CFS-SP SIL Firestop Silicone Joint Spray (Max. JW=3")
English
-
C-AJ-5341
(Approval document / Penetration)
Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)
English
-
C-AJ-2071
(Approval document / Penetration)
Max. 2" Fusiotherm and Climatherm
English
-
HW-D-1125
(Approval document / Joint)
Gypsum wall (with RipTRAK) to concrete over fluted metal deck or flat concrete (Max. JW=4")
English
-
C-AJ-3284
(Firestop System Details / UL Detail Drawing)
Blank or cables (various cables) through CP 653 Speed Sleeve
English
-
F-A-1003
(CAD/BIM Typicals / Auto CAD drawing file)
Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)
English
-
C-AJ-3180
(CAD/BIM Typicals / Auto CAD drawing file)
Cable bundle (various cables) (Steel sleeve optional)
English
-
C-AJ-3216
(Approval document / Penetration)
Cable bundle (various cables) (Steel sleeve)
English
-
C-AJ-5044
(Approval document / Penetration)
Multiple insulated steel and copper pipes (max. 3")
English
-
C-AJ-3284
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or cables (various cables) through CP 653 Speed Sleeve
English
-
C-AJ-3180
(Firestop System Details / UL Detail Drawing)
Cable bundle (various cables) (Steel sleeve optional)
English