15674 Technical documents

  • C-AJ-3239

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional) (bottom side access)

    English

  • C-AJ-3070

    (Firestop System Details / UL Detail Drawing)

    Cables (separated)

    English

    Download File [169 kB]
  • C-AJ-4017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [116 kB]
  • C-AJ-2023

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC, CPVC, or Aquarise CPVC

    English

    Download File [173.4 kB]
  • C-AJ-5044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple insulated steel and copper pipes (max. 3")

    English

  • C-AJ-3070

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cables (separated)

    English

    Download File [249.9 kB]
  • C-AJ-2070

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [253.8 kB]
  • C-AJ-4035

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [145 kB]
  • C-AJ-5342

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)

    English

    Download File [289.4 kB]
  • C-AJ-0004

    (Firestop System Details / UL Detail Drawing)

    Max. 6" diameter blank opening (optional steel sleeve)

    English

  • C-AJ-2061

    (Approval document / Penetration)

    Max. 2" PVC, CPVC, RNC, PEX (closed)

    English

  • C-AJ-3070

    (Approval document / Penetration)

    Cables (separated)

    English

    Download File [276.4 kB]
  • C-AJ-4094

    (Approval document / Penetration)

    cable tray through concrete floor/wall or block wall assembly

    English

    Download File [75.1 kB]
  • F-A-1004

    (Approval document / Penetration)

    Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT

    English

  • C-AJ-5343

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")

    English

  • C-AJ-3232

    (Approval document / Penetration)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [382.9 kB]
  • C-AJ-5342

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)

    English

    Download File [156.6 kB]
  • C-AJ-3279

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in PVC sleeve (2-1/2" concrete)

    English

    Download File [157.8 kB]
  • HW-S-0053

    (Approval document / Joint)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [144.5 kB]
  • F-A-2006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2” PVC waste/overflow fittings

    English

  • C-AJ-3208

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (PVC or steel sleeve)

    English

    Download File [189.4 kB]
  • C-AJ-5342

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper with 1" to 2" glass fiber insulation (optional sleeve)(bottom side access)

    English

    Download File [321.9 kB]
  • C-AJ-3279

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in PVC sleeve (2-1/2" concrete)

    English

    Download File [265.2 kB]
  • F-A-3001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

    Download File [241.1 kB]
  • C-AJ-3208

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (PVC or steel sleeve)

    English

    Download File [288.1 kB]
  • C-AJ-1016

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

  • C-AJ-2024

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC,  CPVC, or Aquarise CPVC  (knock-out sleeve)

    English

    Download File [161.9 kB]
  • C-AJ-5265

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)

    English

    Download File [242.4 kB]
  • C-AJ-4035

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [329.2 kB]
  • C-AJ-2042

    (Approval document / Penetration)

    Max. 2" Blazemaster CPVC plastic pipe

    English

  • C-AJ-5048

    (Approval document / Penetration)

    Max. 2" steel pipe with max. 1" glass fiber insulation

    English

    Download File [140 kB]
  • C-AJ-3210

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [78.1 kB]
  • F-A-2025

    (Approval document / Penetration)

    Max.6" PVC, ABS, CPVC, FRPP, max. 4" RNC or 3" Aquarise CPVC plastic pipe (metal deck)

    English

    Download File [599.7 kB]
  • C-AJ-1010

    (Approval document / Penetration)

    Max. 2" steel, cast iron, copper, steel conduit, EMT (Bottom Side Install for Floors) (AS=0" to 3-7/8")

    English

    Download File [303.4 kB]
  • C-AJ-5265

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)

    English

    Download File [87.1 kB]
  • C-AJ-5044

    (Firestop System Details / UL Detail Drawing)

    Multiple insulated steel and copper pipes (max. 3")

    English

  • C-AJ-2054

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP plastic pipe

    English

    Download File [455.6 kB]
  • C-AJ-2659

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")

    English

    Download File [132.8 kB]
  • F-A-0040

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [428.7 kB]
  • C-AJ-4035

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [189.2 kB]
  • ASSET_DOC_LOC_16707969

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")

    English

    Download File [96.6 kB]
  • C-AJ-2065

    (Firestop System Details / UL Detail Drawing)

    Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)

    English

    Download File [103.2 kB]
  • C-AJ-2022

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC, ABS, FRPP, CPVC, RNC, or 3" Aquarise CPVC

    English

    Download File [169.9 kB]
  • C-AJ-4093

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple cable trays through concrete floor/wall or block wall

    English

    Download File [361.3 kB]
  • C-AJ-5265

    (Approval document / Penetration)

    Max. 6" steel, cast iron, or copper pipe w/ max. 2" glass fiber (optional sleeve)

    English

    Download File [78.8 kB]
  • C-AJ-2659

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")

    English

    Download File [196.5 kB]
  • C-AJ-2065

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)

    English

    Download File [267 kB]
  • C-AJ-4071

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

  • F-A-2013

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PEX Tubing (SDR 9)

    English

    Download File [132.2 kB]
  • C-AJ-3152

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [315 kB]
  • C-AJ-5184

    (Approval document / Penetration)

    Max. 6" steel or copper pipe with max. 3" thick mineral fiber insulation (AS=1/2" to 1-1/2")

    English

  • C-AJ-2021

    (Firestop System Details / UL Detail Drawing)

    Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)

    English

    Download File [262.6 kB]
  • F-A-2005

    (Approval document / Penetration)

    Tub Box with max. 1-1/2” PVC waste/overflow fittings

    English

  • C-AJ-2056

    (Approval document / Penetration)

    Max. 2" PP plastic pipe

    English

    Download File [289.7 kB]
  • C-AJ-4017

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [22.3 kB]
  • C-AJ-3236

    (Firestop System Details / UL Detail Drawing)

    Single Cable (4/C 750 kcmil TEK Cable)

    English

  • C-AJ-3210

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [220.7 kB]
  • C-AJ-3181

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [26.3 kB]
  • C-AJ-3236

    (CAD/BIM Typicals / Auto CAD drawing file)

    Single Cable (4/C 750 kcmil TEK Cable)

    English

  • F-A-2026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP

    English

    Download File [225.2 kB]
  • C-AJ-5198

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with max. 3/4" AB/PVC insulation (2-1/2" concrete) (AS=0" to 1-3/8")

    English

  • C-AJ-3210

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [262.6 kB]
  • C-AJ-3096

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [383.8 kB]
  • C-AJ-1011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)

    English

  • C-AJ-5289

    (Firestop System Details / UL Detail Drawing)

    Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)

    English

    Download File [138.6 kB]
  • C-AJ-2053

    (Approval document / Penetration)

    Max. 6" PVC, ABS, FRPP, CPVC, or XFR (optional sleeve) (oversized opening)

    English

    Download File [103.6 kB]
  • C-AJ-5289

    (Approval document / Penetration)

    Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)

    English

    Download File [322.7 kB]
  • C-AJ-3318

    (Approval document / Penetration)

    Blank or cables through Firestop Cable Transit

    English

    Download File [119.2 kB]
  • HI/BPF 120-31

    (Approval document / Joint)

    Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")

    English

    Download File [135.3 kB]
  • C-AJ-5289

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" copper, steel, or cast iron with 1/2" to 1" AB/PVC insulation (bottom side access)

    English

    Download File [218.8 kB]
  • C-AJ-4093

    (Firestop System Details / UL Detail Drawing)

    Multiple cable trays through concrete floor/wall or block wall

    English

    Download File [46.7 kB]
  • HI/BPF 120-31

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")

    English

    Download File [4.1 MB]
  • C-AJ-2056

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP plastic pipe

    English

    Download File [209.3 kB]
  • C-AJ-5090

    (Approval document / Penetration)

    Max. 4" steel, copper pipe with max. 3/4" AB/PVC insulation (AS=1/2" to 2-1/4")

    English

  • C-AJ-4071

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

  • FW-D-1141

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")

    English

    Download File [350.5 kB]
  • C-AJ-2061

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC, CPVC, RNC, PEX (closed)

    English

  • C-AJ-4077

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack

    English

    Download File [307.2 kB]
  • C-AJ-2057

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation

    English

    Download File [281.8 kB]
  • C-AJ-4083

    (Firestop System Details / UL Detail Drawing)

    Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")

    English

    Download File [162.2 kB]
  • C-AJ-2071

    (Firestop System Details / UL Detail Drawing)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [167.5 kB]
  • C-AJ-5295

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation

    English

  • F-A-1005

    (Firestop System Details / UL Detail Drawing)

    Max. 24" steel, cast iron; max. 6" copper, steel conduit; and max. 4" EMT

    English

  • F-A-2009

    (Approval document)

    Max. 2" PVC, CPVC, Aquarise CPVC, or PEX

    English

    Download File [329.6 kB]
  • C-AJ-2054

    (Approval document / Penetration)

    Max. 2" PP plastic pipe

    English

    Download File [97.3 kB]
  • C-AJ-2659

    (Approval document / Penetration)

    Cable bundle (various cables) in flexible nylon raceway (PVC sleeve optional) (AS=0" to 3")

    English

    Download File [344.5 kB]
  • C-AJ-5295

    (Firestop System Details / UL Detail Drawing)

    Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation

    English

  • C-AJ-1010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, copper, steel conduit, EMT (Bottom Side Install for Floors) (AS=0" to 3-7/8")

    English

    Download File [185.9 kB]
  • C-AJ-3284

    (Approval document / Penetration)

    Blank or cables (various cables) through CP 653 Speed Sleeve

    English

    Download File [81.6 kB]
  • C-AJ-3216

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [107.8 kB]
  • HW-S-0053

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [197.3 kB]
  • F-A-2025

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max.6" PVC, ABS, CPVC, FRPP, max. 4" RNC or 3" Aquarise CPVC plastic pipe (metal deck)

    English

    Download File [446.4 kB]
  • C-AJ-3232

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [246.9 kB]
  • C-AJ-3216

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [122.6 kB]
  • C-AJ-3232

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [161.6 kB]
  • C-AJ-0004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" diameter blank opening (optional steel sleeve)

    English

  • C-AJ-5301

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")

    English

  • C-AJ-2055

    (Approval document)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation

    English

    Download File [99.7 kB]
  • F-A-0040

    (Approval document / Penetration)

    English

    Download File [92 kB]
  • F-A-2006

    (Approval document)

    Tub Box with max. 1-1/2” PVC waste/overflow fittings

    English

  • C-AJ-3281

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve (access both sides)

    English

    Download File [81.7 kB]
  • C-AJ-2072

    (Firestop System Details / UL Detail Drawing)

    Max. 1" PEX (includes hollow core)

    English

  • C-AJ-5301

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")

    English

  • F-A-1004

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT

    English

  • C-AJ-4077

    (Firestop System Details / UL Detail Drawing)

    Cable Rack

    English

    Download File [384.6 kB]
  • C-AJ-2061

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC, CPVC, RNC, PEX (closed)

    English

  • C-AJ-2042

    (Firestop System Details / UL Detail Drawing)

    Max. 2" Blazemaster CPVC plastic pipe

    English

  • C-AJ-4083

    (CAD/BIM Typicals / Auto CAD drawing file)

    Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")

    English

    Download File [259.2 kB]
  • C-AJ-2049

    (Firestop System Details / UL Detail Drawing)

    Nom. 2", 3", or 4" PVDF plastic pipe

    English

    Download File [128.9 kB]
  • C-AJ-4054

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [138.3 kB]
  • C-AJ-2055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation

    English

    Download File [297.7 kB]
  • C-AJ-4094

    (Firestop System Details / UL Detail Drawing)

    Cable tray through concrete floor/wall or block wall assembly

    English

    Download File [133.8 kB]
  • C-AJ-5277

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete

    English

  • C-AJ-0004

    (Approval document)

    Max. 6" diameter blank opening (optional steel sleeve)

    English

  • HW-D-0155

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [97.2 kB]
  • C-AJ-2049

    (Approval document)

    Nom. 2", 3", or 4" PVDF plastic pipe

    English

    Download File [315.4 kB]
  • C-AJ-5277

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete

    English

  • C-AJ-1012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron; 6" copper, steel conduit; or 4" EMT (optional steel sleeve)

    English

  • FW-D-1141

    (Approval document / Joint)

    Concrete floor to wall joint with CFS-SP SIL Firesop Silicone Joint Spray (Max. JW=3")

    English

    Download File [78.6 kB]
  • C-AJ-3209

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeve w/ welded flange)

    English

  • F-A-2034

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" XFR-PVC (bottom side access)

    English

    Download File [205.4 kB]
  • C-AJ-3239

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional) (bottom side access)

    English

  • F-A-1193

    (Approval document / Penetration)

    English

    Download File [94 kB]
  • C-AJ-4077

    (Approval document / Penetration)

    Cable Rack

    English

    Download File [702.7 kB]
  • C-AJ-4093

    (Approval document / Penetration)

    Multiple cable trays through concrete floor/wall or block wall

    English

    Download File [94.1 kB]
  • C-AJ-3236

    (Approval document / Penetration)

    Single Cable (4/C 750 kcmil TEK Cable)

    English

  • C-AJ-3209

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve w/ welded flange)

    English

  • F-A-2009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC, CPVC, Aquarise CPVC, or PEX

    English

    Download File [235 kB]
  • C-AJ-3239

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional) (bottom side access)

    English

  • C-AJ-5341

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)

    English

    Download File [133.7 kB]
  • F-A-1193

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [617.5 kB]
  • C-AJ-2057

    (Approval document)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation

    English

    Download File [469.6 kB]
  • F-A-2026

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP

    English

    Download File [170.8 kB]
  • C-AJ-6006

    (Approval document / Penetration)

    Electrical busway (23" x 4-1/2") (2-1/2" concrete)

    English

    Download File [17 kB]
  • C-AJ-4054

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [19.5 kB]
  • C-AJ-5341

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)

    English

    Download File [252.8 kB]
  • C-AJ-4054

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [116.3 kB]
  • C-AJ-2066

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 50mm Fusiotherm SDR11 PP (closed)

    English

    Download File [253.8 kB]
  • C-AJ-2660

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")

    English

    Download File [196.1 kB]
  • HW-D-0955

    (Firestop System Details / UL Detail Drawing)

    Gypsum Shaft Wall to Flat Concrete Floor (includes Hollow-Core) with CFS-TTS Top Track Seal (Max. JW=19mm)

    English

    Download File [100.2 kB]
  • C-AJ-4094

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable tray through concrete floor/wall or block wall assembly

    English

    Download File [253.7 kB]
  • C-AJ-1011

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)

    English

  • C-AJ-2053

    (Firestop System Details / UL Detail Drawing)

    Max. 6" PVC, ABS, FRPP, CPVC or XFR (optional sleeve) (oversized opening)

    English

    Download File [112.5 kB]
  • C-AJ-4034

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [317.9 kB]
  • C-AJ-2660

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")

    English

    Download File [136.8 kB]
  • C-AJ-2053

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" PVC, ABS, FRPP, CPVC or XFR (optional sleeve) (oversized opening)

    English

    Download File [457.2 kB]
  • C-AJ-5048

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel pipe with max. 1" glass fiber insulation

    English

    Download File [150 kB]
  • C-AJ-5230

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)

    English

  • C-AJ-1011

    (Approval document)

    Max. 4" steel, cast iron, copper, steel conduit, EMT (optional steel sleeve)

    English

  • HW-D-1125

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall (with RipTRAK) to concrete over fluted metal deck or flat concrete (Max. JW=4")

    English

    Download File [1.4 MB]
  • C-AJ-2070

    (Firestop System Details / UL Detail Drawing)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [100.2 kB]
  • C-AJ-1023

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, 6" copper, steel conduit, or 4" EMT (sleeve optional)

    English

  • C-AJ-5061

    (Approval document / Penetration)

    Max. 20" steel, cast iron, max. 6" copper pipe with max. 3" Glass fiber insulation (Steel sleeve optional)

    English

  • F-A-2026

    (Approval document)

    Max. 4" PVC, ABS, CPVC, FRPP, RNC, 3" Aquarise CPVC or max. 2" PP

    English

    Download File [491.8 kB]
  • C-AJ-3209

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve w/ welded flange)

    English

  • C-AJ-2036

    (Approval document)

    Max. 4" PVC, ABS, or CPVC Plastic Pipe

    English

    Download File [362.3 kB]
  • C-AJ-5230

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)

    English

  • C-AJ-1022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, 6" copper, steel conduit or 4" EMT (sleeve optional)

    English

    Download File [117.7 kB]
  • FF-D-0155

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [77.7 kB]
  • C-AJ-3198

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (PVC sleeve)

    English

    Download File [159.8 kB]
  • C-AJ-3281

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve (access both sides)

    English

  • F-A-2005

    (Firestop System Details / UL Detail Drawing)

    Tub Box with max. 1-1/2” PVC waste/overflow fittings

    English

  • C-AJ-3320

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

    Download File [318.8 kB]
  • C-AJ-5301

    (Approval document / Penetration)

    Max. 6" steel, cast iron, or copper with 2" glass fiber insulation (AS=0" to 1-7/8")

    English

  • C-AJ-3198

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (PVC sleeve)

    English

    Download File [195 kB]
  • F-A-2005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2” PVC waste/overflow fittings

    English

  • C-AJ-3281

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve (access both sides)

    English

  • C-AJ-3298

    (Approval document / Penetration)

    Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)

    English

    Download File [88.7 kB]
  • C-AJ-5343

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")

    English

  • C-AJ-3084

    (Approval document / Penetration)

    Cable bundle (telephone cables) PVC sleeve

    English

    Download File [227.2 kB]
  • C-AJ-2057

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1-1/2" Glass Fiber pipe insulation

    English

    Download File [236.7 kB]
  • C-AJ-3198

    (Approval document / Penetration)

    Cable bundle (various cables) (PVC sleeve)

    English

    Download File [288.1 kB]
  • F-A-1003

    (Approval document)

    Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)

    English

  • C-AJ-2065

    (Approval document)

    Max. 125mm Fusiotherm SDR11 or 7.4 PP (closed)

    English

    Download File [412.7 kB]
  • C-AJ-5343

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper with 1/2" to 2" glass fiber insulation (optional sleeve) (AS = 1/4" to 1-1/8")

    English

  • C-AJ-4034

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [43.9 kB]
  • C-AJ-2071

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [275.3 kB]
  • C-AJ-3084

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (telephone cables) PVC sleeve

    English

    Download File [193.1 kB]
  • C-AJ-5048

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel pipe with max. 1" glass fiber insulation

    English

    Download File [230.7 kB]
  • C-AJ-1012

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron; 6" copper, steel conduit; or 4" EMT (optional steel sleeve)

    English

  • C-AJ-3320

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

    Download File [327.2 kB]
  • C-AJ-5096

    (Approval document / Penetration)

    Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")

    English

  • F-A-3001

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

    Download File [140.6 kB]
  • C-AJ-3084

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (telephone cables) PVC sleeve

    English

    Download File [103.1 kB]
  • HW-D-0155

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [323.3 kB]
  • C-AJ-2042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" Blazemaster CPVC plastic pipe

    English

  • C-AJ-5069

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")

    English

  • C-AJ-5185

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")

    English

  • C-AJ-1016

    (Approval document)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

  • C-AJ-3193

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional)

    English

  • C-AJ-5230

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper pipe w/ max. 2" glass fiber (sleeve w/ welded flange)

    English

  • HW-S-0053

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [572.6 kB]
  • C-AJ-5091

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")

    English

  • C-AJ-3095

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional) (2-1/2" Concrete)

    English

  • C-AJ-2056

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP plastic pipe

    English

    Download File [131.1 kB]
  • C-AJ-1022

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, 6" copper, steel conduit or 4" EMT (sleeve optional)

    English

    Download File [119.9 kB]
  • C-AJ-5295

    (Approval document / Penetration)

    Max. 3" steel, cast iron, or copper with 2" polyisocyanurate foam insulation

    English

  • F-A-2034

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" XFR-PVC (bottom side access)

    English

    Download File [25 kB]
  • C-AJ-2024

    (Approval document)

    Max. 2" PVC,  CPVC, or Aquarise CPVC  (knock-out sleeve)

    English

    Download File [345.9 kB]
  • C-AJ-5185

    (Firestop System Details / UL Detail Drawing)

    Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")

    English

  • C-AJ-2021

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)

    English

    Download File [407.7 kB]
  • C-AJ-3181

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [40.1 kB]
  • C-AJ-3283

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve (top side access)

    English

  • WW-D-0270

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Optional one side installation) (Max. JW=2")

    English

    Download File [395.5 kB]
  • C-AJ-3208

    (Approval document / Penetration)

    Cable bundle (various cables) (PVC or steel sleeve)

    English

    Download File [328 kB]
  • C-AJ-3181

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [127.8 kB]
  • F-A-1004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, copper, cast iron, steel conduit, and 4" EMT

    English

  • C-AJ-3283

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve (top side access)

    English

  • C-AJ-5069

    (Approval document / Penetration)

    Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")

    English

  • C-AJ-2660

    (Approval document / Penetration)

    Cable bundle (various cables) in flexible nylon raceway (steel sleeve optional) (AS=0" to 3")

    English

    Download File [384.4 kB]
  • C-AJ-6017

    (Firestop System Details / UL Detail Drawing)

    Electrical busway (26" x 6")

    English

  • C-AJ-3285

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve (top side access)

    English

    Download File [82.2 kB]
  • HW-D-0930

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")

    English

    Download File [423.5 kB]
  • F-A-0001

    (Approval document)

    Max. 10" dia blank opening

    English

  • C-AJ-2070

    (Approval document)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [347.2 kB]
  • F-A-2009

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC, CPVC, Aquarise CPVC, or PEX

    English

    Download File [165.9 kB]
  • C-AJ-6017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Electrical busway (26" x 6")

    English

  • C-AJ-3320

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

    Download File [47.6 kB]
  • C-AJ-3096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [287.2 kB]
  • C-AJ-3319

    (Approval document / Penetration)

    Cables (various) through Firestop Cable Transit

    English

    Download File [402.1 kB]
  • C-AJ-5069

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, max. 6" copper pipe with max. 3" FOAMGLASS insulation (Steel sleeve optional) (AS=3/4" to 3")

    English

  • C-AJ-3318

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Firestop Cable Transit

    English

    Download File [514.5 kB]
  • C-AJ-3096

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional)

    English

    Download File [152.8 kB]
  • HW-D-0930

    (Approval document / Joint)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")

    English

    Download File [93.4 kB]
  • FF-D-1216

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint with CFS-SP SIL Firestop Silicone Joint Spray (Max. JW=3")

    English

    Download File [94.2 kB]
  • C-AJ-2035

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" PVC, ABS, FRPP, or CPVC,max 4" RNC or 3" Aquarise CPVC

    English

    Download File [644.7 kB]
  • C-AJ-5091

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")

    English

  • C-AJ-1023

    (Approval document)

    Max. 30" steel, cast iron, 6" copper, steel conduit, or 4" EMT (sleeve optional)

    English

  • C-AJ-1016

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

  • C-AJ-2055

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP, or Aquarise CPVC plastic pipe with 1" AB/PVC pipe insulation

    English

    Download File [108.3 kB]
  • F-A-0001

    (Firestop System Details / UL Detail Drawing)

    Max. 10" dia blank opening

    English

  • C-AJ-2022

    (Approval document)

    Max. 4" PVC, ABS, FRPP, CPVC, RNC, or 3" Aquarise CPVC

    English

    Download File [377.1 kB]
  • C-AJ-4071

    (Approval document / Penetration)

    Cable Tray

    English

  • F-A-1002

    (Firestop System Details / UL Detail Drawing)

    Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)

    English

  • C-AJ-2023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC, CPVC, or Aquarise CPVC

    English

    Download File [193.2 kB]
  • WW-D-0270

    (Approval document / Joint)

    Concrete wall to wall joint (Optional one side installation) (Max. JW=2")

    English

    Download File [91.9 kB]
  • C-AJ-3152

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [168.7 kB]
  • C-AJ-3285

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve (top side access)

    English

  • C-AJ-6017

    (Approval document / Penetration)

    Electrical busway (26" x 6")

    English

  • C-AJ-5091

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" copper pipe with nom. 2" glass fiber or max. 2" thick calcium silicate insulation (Steel sleeve optional) (AS=1/2" to 2-1/4")

    English

  • C-AJ-3152

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [190.5 kB]
  • F-A-1002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)

    English

  • C-AJ-3285

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve (top side access)

    English

  • C-AJ-2072

    (Approval document)

    Max. 1" PEX (includes hollow core)

    English

  • C-AJ-4083

    (Approval document / Penetration)

    Steel or Aluminum Cable Tray (36" x 6") (AS=0" to 2-1/4")

    English

    Download File [79.5 kB]
  • W-L-2027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" PVC or CPVC

    English

    Download File [255.1 kB]
  • C-AJ-1184

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")

    English

  • F-A-5005

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber

    English

  • C-AJ-1342

    (Approval document / Penetration)

    Max. 8" aluminum tubing (AS=1/2" to 1-1/2")

    English

  • W-L-2056

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP, Fusiotherm or Climatherm

    English

    Download File [180.9 kB]
  • C-AJ-1388

    (Approval document / Penetration)

    Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)

    English

    Download File [29.9 kB]
  • W-J-2028

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [133.8 kB]
  • W-L-2044

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (sch 80)

    English

    Download File [127 kB]
  • C-AJ-1453

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")

    English

    Download File [153.4 kB]
  • C-AJ-1291

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")

    English

  • C-AJ-1453

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")

    English

    Download File [83.6 kB]
  • C-AJ-1453

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (optional sleeve) (AS=0" to 1-7/8")

    English

    Download File [283.6 kB]
  • C-AJ-0058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" blank opening (no sleeve)

    English

    Download File [122 kB]
  • W-J-2011

    (Approval document / Penetration)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [19.1 kB]
  • C-AJ-1184

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")

    English

  • C-AJ-0055

    (Approval document / Penetration)

    Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)

    English

    Download File [148.8 kB]
  • C-AJ-0086

    (Approval document / Penetration)

    Max. 6" un-sleeved blank opening

    English

    Download File [21.7 kB]
  • C-AJ-1498

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")

    English

  • C-AJ-0058

    (Firestop System Details / UL Detail Drawing)

    Max. 4" blank opening (no sleeve)

    English

    Download File [84 kB]
  • C-AJ-1498

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")

    English

  • C-AJ-1277

    (Approval document / Penetration)

    Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")

    English

    Download File [18.8 kB]
  • C-AJ-1498

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 6" steel conduit, 4" EMT or copper (optional sleeve) (AS=0" to 2")

    English

  • W-J-2016

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)

    English

  • F-C-2007

    (Firestop System Details / UL Detail Drawing)

    Max 4” PVC, CPVC, or 4" Aquarise CPVC Plastic Pipe

    English

    Download File [103.1 kB]
  • W-L-2038

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more)

    English

  • W-L-2050

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [145.4 kB]
  • C-AJ-1156

    (Firestop System Details / UL Detail Drawing)

    Max. 21" steel pipe (AS=0" to 3")

    English

  • C-AJ-1575

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)

    English

  • W-L-2038

    (Approval document / Penetration)

    Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more))

    English

  • F-A-3002

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

  • C-AJ-1156

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" steel pipe (AS=0" to 3")

    English

  • W-L-2031

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC

    English

    Download File [327.6 kB]
  • W-L-2019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [110.8 kB]
  • C-AJ-1276

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, conduit, or EMT pipe (AS=3/4")

    English

    Download File [105.6 kB]
  • F-B-2006

    (Approval document / Penetration)

    Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc

    English

    Download File [374.9 kB]
  • C-AJ-1226

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")

    English

  • W-L-2047

    (Approval document / Penetration)

    Max 1" PEX (SDR 9) (max qty = 6) (closed)

    English

  • C-AJ-1276

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, conduit, or EMT pipe (AS=3/4")

    English

    Download File [21.9 kB]
  • F-C-2005

    (Firestop System Details / UL Detail Drawing)

    Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe

    English

    Download File [116.6 kB]
  • W-L-8001

    (Firestop System Details / UL Detail Drawing)

    Multiple HVAC Line Sets

    English

  • C-AJ-1435

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

    Download File [22.9 kB]
  • C-AJ-1435

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

    Download File [113.1 kB]
  • C-AJ-0074

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)

    English

    Download File [103.7 kB]
  • F-E-2005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" PEX or Aquarise CPVC

    English

    Download File [226.5 kB]
  • C-AJ-1517

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")

    English

    Download File [129.5 kB]
  • C-AJ-0074

    (Firestop System Details / UL Detail Drawing)

    Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)

    English

    Download File [78.5 kB]
  • C-AJ-1517

    (Firestop System Details / UL Detail Drawing)

    Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")

    English

    Download File [24.8 kB]
  • F-A-5004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel or cast iron with 1-1/2" glass fiber

    English

  • C-AJ-1154

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")

    English

  • F-B-2009

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC transitioning to steel

    English

    Download File [100.4 kB]
  • W-L-2031

    (Approval document / Penetration)

    Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC

    English

    Download File [515 kB]
  • F-A-8002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated metallic pipes, conduits and  cables (single or bundled) in max. 30" x 48" opening

    English

  • C-AJ-1154

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")

    English

  • W-J-2012

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC

    English

    Download File [235.3 kB]
  • W-J-2016

    (Approval document / Penetration)

    Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)

    English

  • W-L-2038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" PVC, CPVC, RNC, Blazemaster CPVC, or max. 1" PEX (one or more)

    English

  • C-AJ-1149

    (Approval document / Penetration)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")

    English

    Download File [359.4 kB]
  • C-AJ-1610

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")

    English

    Download File [372.3 kB]
  • W-L-0003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" blank steel sleeve

    English

    Download File [225.1 kB]
  • C-AJ-1609

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")

    English

    Download File [352.8 kB]
  • C-AJ-1278

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")

    English

  • F-C-2005

    (Approval document / Penetration)

    Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe

    English

    Download File [338.2 kB]
  • W-L-2056

    (Approval document / Penetration)

    Max. 2" PP, Fusiotherm or Climatherm

    English

    Download File [824.3 kB]
  • C-AJ-1278

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")

    English

  • W-L-7007

    (Firestop System Details / UL Detail Drawing)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-1421

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")

    English

  • F-C-2009

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" PVC or ABS bathtub fittings

    English

    Download File [147 kB]
  • W-J-2246

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (sch 80)

    English

    Download File [123.8 kB]
  • C-AJ-1421

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")

    English

  • W-J-2012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC

    English

    Download File [116.5 kB]
  • W-L-8001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple HVAC Line Sets

    English

  • C-AJ-0082

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)

    English

    Download File [97.9 kB]
  • C-AJ-1276

    (Approval document / Penetration)

    Max. 4" steel, conduit, or EMT pipe (AS=3/4")

    English

    Download File [18.7 kB]
  • F-C-2378

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX

    English

  • C-AJ-1572

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")

    English

    Download File [192.3 kB]
  • W-J-2028

    (Approval document / Penetration)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [317.2 kB]
  • C-AJ-0082

    (Firestop System Details / UL Detail Drawing)

    Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)

    English

    Download File [77 kB]
  • C-AJ-1572

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")

    English

    Download File [143.9 kB]
  • C-AJ-1572

    (Approval document / Penetration)

    Max. 2" steel, cast iron, steel conduit or EMT (bottom side access) (AS=3/16" to 7/16")

    English

    Download File [29.1 kB]
  • C-AJ-1149

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")

    English

    Download File [204.2 kB]
  • C-AJ-1454

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)

    English

  • W-L-2027

    (Approval document / Penetration)

    Max. 12" PVC or CPVC

    English

    Download File [420.8 kB]
  • F-B-2009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC transitioning to steel

    English

    Download File [291.7 kB]
  • C-AJ-1149

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-1/4")

    English

    Download File [243.8 kB]
  • W-L-0003

    (Firestop System Details / UL Detail Drawing)

    Max. 4" blank steel sleeve

    English

    Download File [121.4 kB]
  • W-L-2044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (sch 80)

    English

    Download File [236 kB]
  • W-J-7001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-1326

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")

    English

  • F-C-2007

    (Approval document / Penetration)

    Max 4” PVC, CPVC, or 4" Aquarise CPVC Plastic Pipe

    English

    Download File [382.7 kB]
  • W-L-7007

    (Approval document / Penetration)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-0082

    (Approval document / Penetration)

    Max. 288 sq. in. un-sleeved blank opening with max. dimension of 24" (CP 637 Firestop Mortar)

    English

    Download File [22.2 kB]
  • C-AJ-1326

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")

    English

  • C-AJ-1449

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")

    English

    Download File [22.6 kB]
  • C-AJ-1326

    (Approval document / Penetration)

    Max. 1" flexible steel conduit (AS=1/2" to 1-1/2")

    English

  • C-AJ-1382

    (Firestop System Details / UL Detail Drawing)

    Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")

    English

    Download File [33.9 kB]
  • C-AJ-2218

    (Approval document / Penetration)

    Max. 3" PVC or CPVC (closed or open)

    English

  • C-AJ-1382

    (Approval document / Penetration)

    Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")

    English

    Download File [23.1 kB]
  • F-A-3074

    (Approval document / Penetration)

    English

    Download File [83.4 kB]
  • C-AJ-1382

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" Copper, steel, cast iron, steel conduit or EMT (AS=0" to 5-7/8")

    English

    Download File [107 kB]
  • W-J-2019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" PVC or CPVC

    English

    Download File [207.9 kB]
  • F-B-2006

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc

    English

    Download File [126.2 kB]
  • W-L-5010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)

    English

    Download File [234.4 kB]
  • F-E-2005

    (Firestop System Details / UL Detail Drawing)

    Max. 1" PEX or Aquarise CPVC

    English

    Download File [94.5 kB]
  • F-C-2010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nom. 4" ABS or PVC closet flange

    English

    Download File [190.5 kB]
  • C-AJ-1597

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" steel conduit, 4" EMT or copper (AS=0" to 2")

    English

  • C-AJ-0090

    (Firestop System Details / UL Detail Drawing)

    Max. 6" blank opening (optional steel pipe sleeve)

    English

  • C-AJ-1346

    (Approval document / Penetration)

    Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")

    English

  • C-AJ-1610

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")

    English

    Download File [227.7 kB]
  • C-AJ-1421

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, steel conduit or EMT (Optional sleeve) (AS=0" to 5-3/8")

    English

  • C-AJ-0138

    (Firestop System Details / UL Detail Drawing)

    Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block

    English

    Download File [95.4 kB]
  • C-AJ-0058

    (Approval document / Penetration)

    Max. 4" blank opening (no sleeve)

    English

    Download File [16.7 kB]
  • W-L-2019

    (Approval document / Penetration)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [19.8 kB]
  • C-AJ-1610

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or steel conduit (glass fiber duct insulation above floor) (AS=0" to 1-1/2")

    English

    Download File [297.7 kB]
  • F-C-2006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe

    English

    Download File [252 kB]
  • C-AJ-1278

    (Approval document / Penetration)

    Max. 30" steel, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 7/8")

    English

  • C-AJ-0138

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block

    English

    Download File [252.8 kB]
  • W-L-2047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max 1" PEX (SDR 9) (max qty = 6) (closed)

    English

  • W-L-2019

    (Firestop System Details / UL Detail Drawing)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [317.6 kB]
  • W-J-2246

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (sch 80)

    English

    Download File [237.6 kB]
  • C-AJ-1346

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")

    English

  • F-C-2010

    (Approval document)

    Nom. 4" ABS or PVC closet flange

    English

    Download File [288.9 kB]
  • C-AJ-1346

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit or steel gas piping (2-1/2" Concrete) (AS=1/2" to 1-1/4")

    English

  • F-E-2006

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC, ABS, CPVC, or Aquarise CPVC Plastic Pipe

    English

    Download File [150.7 kB]
  • C-AJ-1372

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")

    English

    Download File [36.5 kB]
  • C-AJ-1513

    (Approval document / Penetration)

    Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")

    English

  • F-C-2011

    (Approval document)

    Max 4" PVC, ABS, CPVC, Aquarise CPVC or XFR-PVC Plastic Pipe

    English

    Download File [82.9 kB]
  • C-AJ-1372

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")

    English

    Download File [284.9 kB]
  • W-J-2245

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [339.4 kB]
  • C-AJ-0105

    (Approval document / Penetration)

    Max. 24" x 24" opening

    English

    Download File [86.3 kB]
  • W-L-2050

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [342.3 kB]
  • W-L-2031

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC, ABS, CPVC, RNC or max. 3" Aquarise CPVC

    English

    Download File [173.7 kB]
  • C-AJ-0105

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" opening

    English

    Download File [210.8 kB]
  • F-C-2007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max 4” PVC, CPVC, or 3" Aquarise CPVC Plastic Pipe

    English

    Download File [298.1 kB]
  • C-AJ-1609

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")

    English

    Download File [295.8 kB]
  • W-L-2018

    (Approval document)

    Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC

    English

    Download File [673 kB]
  • C-AJ-0105

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 24" opening

    English

    Download File [239 kB]
  • C-AJ-1609

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit, EMT, or 3" copper (PVC sleeve) (AS = 0" to 2-7/8")

    English

    Download File [138.8 kB]
  • C-AJ-1184

    (Approval document / Penetration)

    Max. 10" steel, cast iron, max. 4" copper, conduit or EMT pipe (includes Hollow Core) (AS=0" to 3-1/4")

    English

  • C-AJ-1606

    (Firestop System Details / UL Detail Drawing)

    One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")

    English

    Download File [114.3 kB]
  • C-AJ-0097

    (Firestop System Details / UL Detail Drawing)

    Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)

    English

    Download File [106.1 kB]
  • C-AJ-1140

    (Approval document / Penetration)

    Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)

    English

    Download File [78.3 kB]
  • W-L-0003

    (Approval document)

    Max. 4" blank steel sleeve

    English

    Download File [310.9 kB]
  • C-AJ-1606

    (CAD/BIM Typicals / Auto CAD drawing file)

    One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")

    English

    Download File [200.9 kB]
  • C-AJ-0097

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)

    English

    Download File [133.8 kB]
  • W-J-2247

    (Approval document / Penetration)

    Nom. 2" PP (sch 80)

    English

    Download File [95.5 kB]
  • W-L-2056

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP, Fusiotherm or Climatherm

    English

    Download File [226.4 kB]
  • F-C-2378

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX

    English

  • W-L-2043

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [150.4 kB]
  • W-J-2028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [319.9 kB]
  • C-AJ-1380

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")

    English

  • F-C-2378

    (Approval document)

    Max. 2" PVC, ABS, CPVC, Aquarise CPVC, or 1" PEX

    English

  • C-AJ-1380

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")

    English

  • C-AJ-1342

    (Firestop System Details / UL Detail Drawing)

    Max. 8" aluminum tubing (AS=1/2" to 1-1/2")

    English

  • W-L-8001

    (Approval document)

    Multiple HVAC Line Sets

    English

  • F-C-2009

    (Approval document)

    Max. 1-1/2" PVC or ABS bathtub fittings

    English

    Download File [367 kB]
  • C-AJ-1342

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" aluminum tubing (AS=1/2" to 1-1/2")

    English

  • F-A-5005

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber

    English

  • W-J-2247

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (sch 80)

    English

    Download File [404.7 kB]
  • W-L-2047

    (Firestop System Details / UL Detail Drawing)

    Max 1" PEX (SDR 9) (max qty = 6) (closed)

    English

  • W-L-2045

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nom. 2" PP (sch 80)

    English

    Download File [374.8 kB]
  • C-AJ-1140

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)

    English

    Download File [294.7 kB]
  • F-C-2005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1” PEX or 1" Aquarise CPVC Plastic Pipe

    English

    Download File [212.4 kB]
  • W-L-2020

    (Approval document)

    Max. 2" PVC

    English

    Download File [19.1 kB]
  • C-AJ-1606

    (Approval document / Penetration)

    One or more max. 4" steel, cast iron, steel conduit, or EMT (max. 32" x 18" opening) (AS=0" to 7")

    English

    Download File [24.2 kB]
  • C-AJ-1154

    (Approval document / Penetration)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (foam as backer) (AS=0" to 3-1/4")

    English

  • C-AJ-1140

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, max. 4" copper, conduit or EMT pipe (one or more) (2-1/2" Concrete) (AS Varies)

    English

    Download File [145.9 kB]
  • C-AJ-1575

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)

    English

  • C-AJ-0086

    (Firestop System Details / UL Detail Drawing)

    Max. 6" un-sleeved blank opening

    English

    Download File [79.2 kB]
  • W-J-7001

    (Approval document)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-1575

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" steel conduit, max. 4" EMT and copper (sleeve optional) (min. 2-1/2" concrete) (bottom of top access) (with and without backer)

    English

  • F-C-2011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max 4" PVC, ABS, CPVC, Aquarise CPVC or XFR-PVC Plastic Pipe

    English

    Download File [326.4 kB]
  • C-AJ-0086

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" un-sleeved blank opening

    English

    Download File [100.6 kB]
  • W-L-7007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-1156

    (Approval document / Penetration)

    Max. 20" steel pipe (AS=0" to 3")

    English

  • W-J-2016

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" PVC, CPVC, RNC, or max. 1" PEX (max qty = 3)

    English

  • C-AJ-1388

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)

    English

    Download File [101.4 kB]
  • F-E-2005

    (Approval document)

    Max. 1" PEX or Aquarise CPVC

    English

    Download File [337 kB]
  • W-J-2245

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [155.8 kB]
  • F-A-5004

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel or cast iron with 1-1/2" glass fiber

    English

  • C-AJ-1388

    (Firestop System Details / UL Detail Drawing)

    Max. 4" Steel conduit or EMT (Multiple in max 32" x 7" opening) (AS varies)

    English

    Download File [48.3 kB]
  • C-AJ-2218

    (Firestop System Details / UL Detail Drawing)

    Max. 3" PVC or CPVC (closed or open)

    English

  • C-AJ-1291

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")

    English

  • C-AJ-1534

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")

    English

  • W-L-5010

    (Approval document)

    Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)

    English

    Download File [454.7 kB]
  • C-AJ-2218

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" PVC or CPVC (closed or open)

    English

  • F-C-2006

    (Approval document)

    Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe

    English

    Download File [426.3 kB]
  • C-AJ-1291

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 7/8")

    English

  • W-L-2043

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [330.2 kB]
  • W-L-2045

    (Firestop System Details / UL Detail Drawing)

    Nom. 2" PP (sch 80)

    English

    Download File [99.9 kB]
  • F-B-2006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" PP (SDR 11) or max. 40mm Fusiotherm pipe mfg by Aquatherm, Inc

    English

    Download File [220.9 kB]
  • W-L-2028

    (Approval document)

    Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC

    English

    Download File [449.1 kB]
  • C-AJ-1150

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, conduit or max. 4" EMT pipe (AS=0" to 1-3/8")

    English

    Download File [192.3 kB]
  • W-J-2246

    (Approval document / Penetration)

    Max. 2" PP (sch 80)

    English

    Download File [263.1 kB]
  • F-A-3002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

  • C-AJ-0081

    (Approval document / Penetration)

    Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)

    English

    Download File [27.8 kB]
  • C-AJ-1534

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")

    English

  • C-AJ-0081

    (Firestop System Details / UL Detail Drawing)

    Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)

    English

    Download File [171.2 kB]
  • C-AJ-1435

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

    Download File [20.1 kB]
  • W-J-2019

    (Approval document)

    Max. 12" PVC or CPVC

    English

    Download File [371 kB]
  • C-AJ-1534

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (bottoms side access) (AS=0" to 1-7/8")

    English

  • F-A-3074

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [343.1 kB]
  • C-AJ-0081

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 32" x 32" un-sleeved blank opening (CP 637 Firestop Mortar)

    English

    Download File [98.3 kB]
  • W-J-2011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [110.4 kB]
  • C-AJ-1380

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (2-1/2" Concrete) (AS=0" to 1-7/8")

    English

  • C-AJ-1425

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

    Download File [189.7 kB]
  • C-AJ-1425

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

  • W-L-2028

    (Firestop System Details / UL Detail Drawing)

    Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC

    English

    Download File [220 kB]
  • C-AJ-1372

    (Approval document / Penetration)

    Max. 8" steel, max. 4" copper, conduit or EMT pipe (AS=0" to 1-7/8")

    English

    Download File [288.5 kB]
  • C-AJ-1277

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")

    English

    Download File [22.2 kB]
  • W-L-2050

    (Approval document)

    Max. 2" PP (SDR 11), max. 110 Fusiotherm (SDR 7.4 w/ faser), or max. 50mm Fusiotherm (SDR 11) (closed)

    English

    Download File [837.1 kB]
  • F-B-2009

    (Approval document)

    Max. 4" PVC transitioning to steel

    English

    Download File [294 kB]
  • C-AJ-1277

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, conduit, or EMT pipe (AS=0" to 1-13/16")

    English

    Download File [104.9 kB]
  • C-AJ-1425

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (AS=0" to 1-7/8")

    English

    Download File [76.2 kB]
  • W-L-2018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC

    English

    Download File [324.7 kB]
  • W-L-2032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal  6" PVC

    English

    Download File [234.7 kB]
  • C-AJ-1155

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")

    English

  • F-A-3001

    (Approval document)

    Cable bundle (various cables)

    English

    Download File [344.8 kB]
  • W-L-2032

    (Approval document)

    Nominal  6" PVC

    English

    Download File [350.4 kB]
  • C-AJ-0074

    (Approval document / Penetration)

    Max. 32" x 32" un-sleeved blank opening (Min 2-1/2" Concrete) (CP 637 Firestop Mortar)

    English

    Download File [29.2 kB]
  • C-AJ-1155

    (Firestop System Details / UL Detail Drawing)

    Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")

    English

  • F-A-5005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper with 1" to 1-1/2" glass fiber

    English

  • W-L-2020

    (Firestop System Details / UL Detail Drawing)

    Max. 2" PVC

    English

    Download File [238.2 kB]
  • F-A-3002

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

  • C-AJ-0097

    (Approval document / Penetration)

    Max. 4" blank opening (Steel sleeve optional for CFS-PL Firestop Plug)

    English

    Download File [18.1 kB]
  • F-C-2010

    (Firestop System Details / UL Detail Drawing)

    Nom. 4" ABS or PVC closet flange

    English

    Download File [108.1 kB]
  • C-AJ-1513

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")

    English

  • C-AJ-0070

    (Firestop System Details / UL Detail Drawing)

    Max. 7" un-sleeved blank opening

    English

  • W-J-2012

    (Approval document)

    Max. 2" PVC

    English

    Download File [19 kB]
  • C-AJ-1513

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel conduits, EMT's, or max. 2" flexible steel gas piping (one or more) in 30" x 8" opening (AS=0" to 12")

    English

  • F-E-2006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC, ABS, CPVC, or Aquarise CPVC Plastic Pipe

    English

    Download File [419.8 kB]
  • C-AJ-1517

    (Approval document / Penetration)

    Max. 24" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT (AS=0" to 2")

    English

    Download File [23.6 kB]
  • C-AJ-1449

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")

    English

    Download File [106.6 kB]
  • C-AJ-0138

    (Approval document / Penetration)

    Max 12" x 24" Blank Opening Through Concrete Floor/Wall or Block Wall Assembly with CFS-BL Firestop Block

    English

    Download File [213.5 kB]
  • W-J-2245

    (Approval document / Penetration)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [441.1 kB]
  • C-AJ-1449

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" conduit, max. 4" copper or EMT (AS=0" to 5-1/4")

    English

    Download File [221.1 kB]
  • W-L-5010

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, or 2" copper with max. 2" thick glass fiber (shaft wall)

    English

    Download File [153.5 kB]
  • W-L-2032

    (Firestop System Details / UL Detail Drawing)

    Nominal  6" PVC

    English

    Download File [139.2 kB]
  • F-C-2006

    (Firestop System Details / UL Detail Drawing)

    Max. 2” PVC, CPVC, ABS, or Aquarise CPVC Plastic Pipe

    English

    Download File [182.2 kB]
  • W-J-7001

    (Firestop System Details / UL Detail Drawing)

    Max. 48" x 24" sheet metal duct with 1-1/2" thick glass fiber insulation

    English

  • C-AJ-1226

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")

    English

  • C-AJ-1158

    (Approval document / Penetration)

    Max/ 10" steel or cast iron pipe (AS=0" to 1-1/4")

    English

    Download File [307.1 kB]
  • W-L-2045

    (Approval document)

    Nom. 2" PP (sch 80)

    English

    Download File [95.4 kB]
  • F-A-8002

    (Approval document)

    Insulated or non-insulated metallic pipes, conduits and  cables (single or bundled) in max. 30" x 48" opening

    English

  • C-AJ-1226

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 1-7/8")

    English

  • W-L-2020

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC

    English

    Download File [116.9 kB]
  • W-L-2028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" PVC, ABS, FRPP, CPVC, Aquarise CPVC or Max. 4" RNC

    English

    Download File [362 kB]
  • C-AJ-1158

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel or cast iron pipe (AS=0" to 1-1/4")

    English

    Download File [207 kB]
  • F-A-5004

    (Approval document)

    Max. 6" steel or cast iron with 1-1/2" glass fiber

    English

  • W-L-2043

    (Approval document)

    Max. 2" PP (sch 80) with 1" AB/PVC or 1-1/2" Glass fiber pipe insulation

    English

    Download File [822.1 kB]
  • C-AJ-1158

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel or cast iron pipe (AS=0" to 1-1/4")

    English

    Download File [131.6 kB]
  • W-L-2027

    (Firestop System Details / UL Detail Drawing)

    Max. 12" PVC or CPVC

    English

    Download File [150.8 kB]
  • C-AJ-1155

    (Approval document / Penetration)

    Max. 20" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe (Sleeve Optional) (AS=0" to 2-1/4")

    English

  • W-J-2011

    (Firestop System Details / UL Detail Drawing)

    Max/ 1-1/2" PVC or 1" PEX

    English

    Download File [245.4 kB]
  • W-L-2018

    (Firestop System Details / UL Detail Drawing)

    Max. 4" PVC, CPVC, ABS, FRPP, RNC or 3" Aquarise CPVC

    English

    Download File [200.5 kB]
  • C-AJ-1454

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)

    English

  • C-AJ-0055

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)

    English

    Download File [86.5 kB]
  • C-AJ-1454

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or 4" EMT (sleeve w/ welded flange) (AS varies)

    English

  • C-AJ-0055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel pipe sleeve blank opening (CFS-BL Firestop Block)

    English

    Download File [109.1 kB]
  • C-BJ-4026

    (Approval document / Penetration)

    Cable Rack (Telecom)

    English

    Download File [100 kB]
  • C-AJ-8044

    (Firestop System Details / UL Detail Drawing)

    Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")

    English

  • F-A-1192

    (Approval document / Penetration)

    English

    Download File [103.3 kB]
  • F-A-1018

    (Approval document / Penetration)

    Max. 1" flexible steel conduit

    English

  • C-AJ-8041

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)

    English

  • C-BJ-8014

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack (Telecom)

    English

    Download File [219.2 kB]
  • F-A-1016

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)

    English

    Download File [188.3 kB]
  • C-AJ-6036

    (CAD/BIM Typicals / Auto CAD drawing file)

    Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")

    English

    Download File [116.8 kB]
  • F-A-1017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [377.7 kB]
  • C-AJ-7006

    (Firestop System Details / UL Detail Drawing)

    Max. 36" grease duct manufactured by Metal-Fab (AS=1")

    English

  • C-AJ-8210

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [47.5 kB]
  • C-AJ-7104

    (Approval document / Penetration)

    Max. 24" x 12" sheet metal duct w/o damper (bottom side access)

    English

  • C-BJ-8027

    (Firestop System Details / UL Detail Drawing)

    Single HVAC Line set (8" hollow core)

    English

  • C-AJ-8177

    (Approval document / Penetration)

    Insulated or non-insulated metallic pipes, conduits, non-metallic pipes cables, and sheet metal duct

    English

    Download File [51.9 kB]
  • F-A-1023

    (Approval document / Penetration)

    Max. 2" and 3" Steel conduit or EMT

    English

    Download File [341.6 kB]
  • F-A-0005

    (Firestop System Details / UL Detail Drawing)

    Blank CP 680-P (2-1/2" Concrete)

    English

    Download File [91.7 kB]
  • C-AJ-8208

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [160.1 kB]
  • C-AJ-6036

    (Firestop System Details / UL Detail Drawing)

    Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")

    English

    Download File [177.3 kB]
  • F-A-0014

    (Approval document / Penetration)

    Blank CP 680-M or CP 680-P

    English

    Download File [306.7 kB]
  • C-AJ-8210

    (Approval document / Penetration)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [553.8 kB]
  • F-A-1014

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, 6" copper, conduit or 4" EMT pipe

    English

  • C-AJ-7006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 36" grease duct manufactured by Metal-Fab (AS=1")

    English

  • W-J-1088

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • C-AJ-8209

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [247 kB]
  • C-BJ-8024

    (CAD/BIM Typicals / Auto CAD drawing file)

    One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")

    English

  • C-AJ-7145

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation

    English

  • C-AJ-7098

    (Approval document / Penetration)

    Max. 49" x 49" steel grease duct with 1-1/2" Firemaster« Fast Wrap manufactured by Thermal Ceramics

    English

  • C-AJ-8058

    (Firestop System Details / UL Detail Drawing)

    Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)

    English

  • W-J-1088

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • W-J-1042

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • C-AJ-8038

    (Firestop System Details / UL Detail Drawing)

    Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")

    English

  • C-BJ-8010

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle

    English

    Download File [469.6 kB]
  • C-AJ-8056

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)

    English

    Download File [264.6 kB]
  • C-AJ-7084

    (Approval document / Penetration)

    Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)

    English

    Download File [293.3 kB]
  • C-BJ-8010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle

    English

    Download File [255.9 kB]
  • C-AJ-8110

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)

    English

    Download File [526.7 kB]
  • C-AJ-8178

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set w/ PVC drain

    English

    Download File [274.2 kB]
  • C-BJ-8027

    (Approval document / Penetration)

    Single HVAC Line set (8" hollow core)

    English

  • F-A-1022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)

    English

    Download File [217.6 kB]
  • C-AJ-7046

    (Firestop System Details / UL Detail Drawing)

    Max. 32" x 32" sheet metal duct w/o damper

    English

  • C-BJ-0022

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" unsleeved opening

    English

    Download File [120 kB]
  • C-BJ-8020

    (Firestop System Details / UL Detail Drawing)

    Multiple bundle of metallic pipes and cables

    English

  • C-AJ-8180

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)

    English

    Download File [35.8 kB]
  • C-AJ-8099

    (Approval document / Penetration)

    Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)

    English

  • F-A-0012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 12" or 12" diameter blank opening

    English

    Download File [192.1 kB]
  • C-AJ-7030

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated Flamebar BW11 Coated Fire Rated Ductwork

    English

    Download File [274.1 kB]
  • C-AJ-7029

    (Approval document / Penetration)

    Flamebar BW 11 Fire Rated Duct Work

    English

    Download File [143.9 kB]
  • C-BJ-3032

    (Approval document / Penetration)

    Cables (various) through Firestop Cable Transit

    English

    Download File [151.3 kB]
  • C-BJ-1046

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

  • W-J-0007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 36" blank opening

    English

    Download File [225 kB]
  • C-AJ-7123

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")

    English

  • C-BJ-1045

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [282.7 kB]
  • C-AJ-8095

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [54.8 kB]
  • F-A-1029

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe

    English

  • C-AJ-8107

    (Approval document / Penetration)

    Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)

    English

    Download File [411.4 kB]
  • C-BJ-3024

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

  • C-AJ-6042

    (Approval document / Penetration)

    electrical busway through concrete floor/wall or block wall

    English

    Download File [73.8 kB]
  • C-AJ-8096

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [62.4 kB]
  • W-J-1028

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")

    English

  • C-AJ-7140

    (Firestop System Details / UL Detail Drawing)

    Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")

    English

    Download File [180.4 kB]
  • C-BJ-8013

    (Approval document / Penetration)

    Cable Rack (Telecom)

    English

    Download File [496.4 kB]
  • C-AJ-8081

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel tube and cables (AS varies)

    English

  • C-BJ-5018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • C-AJ-8166

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set (optional sleeve) (bottom side access)

    English

  • F-A-1028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)

    English

  • C-AJ-7095

    (Approval document / Penetration)

    Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")

    English

  • C-AJ-7084

    (Firestop System Details / UL Detail Drawing)

    Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)

    English

    Download File [100.2 kB]
  • C-AJ-8081

    (Approval document / Penetration)

    Max. 6" steel tube and cables (AS varies)

    English

  • C-BJ-1037

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete

    English

  • C-BJ-7005

    (Approval document / Penetration)

    Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)

    English

  • C-BJ-8013

    (Firestop System Details / UL Detail Drawing)

    Cable Rack (Telecom)

    English

    Download File [184.8 kB]
  • F-A-0014

    (Firestop System Details / UL Detail Drawing)

    Blank CP 680-M or CP 680-P

    English

    Download File [95.5 kB]
  • F-A-0006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank CP 680-P

    English

    Download File [214.1 kB]
  • C-AJ-7051

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 30" sheet metal duct w/o damper

    English

    Download File [254.6 kB]
  • W-J-1042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • C-BJ-1034

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, conduit or EMT pipe

    English

  • C-BJ-1059

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")

    English

  • W-J-0010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" blank opening (optional sleeve)

    English

    Download File [138.1 kB]
  • C-AJ-8056

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)

    English

    Download File [500.2 kB]
  • F-A-1192

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [674.9 kB]
  • C-BJ-5015

    (Approval document / Penetration)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • W-J-1058

    (Approval document / Penetration)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • C-AJ-8099

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)

    English

  • F-A-1014

    (Approval document / Penetration)

    Max. 12" steel, 6" copper, conduit or 4" EMT pipe

    English

  • C-BJ-4026

    (Firestop System Details / UL Detail Drawing)

    Cable Rack (Telecom)

    English

    Download File [205.6 kB]
  • W-J-1020

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, copper, conduit or EMT pipe

    English

  • C-AJ-7122

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")

    English

  • F-A-1022

    (Approval document / Penetration)

    Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)

    English

    Download File [350.1 kB]
  • C-AJ-8178

    (Approval document / Penetration)

    HVAC line set w/ PVC drain

    English

    Download File [571.2 kB]
  • C-AJ-7111

    (Approval document / Penetration)

    Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)

    English

  • C-AJ-8096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [351.2 kB]
  • C-BJ-4025

    (Approval document / Penetration)

    Cable Rack (Telecom)

    English

    Download File [99.5 kB]
  • C-BJ-5013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper with max. 1" glass fiber insulation

    English

  • C-BJ-3031

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [513.6 kB]
  • C-BJ-5006

    (Approval document / Penetration)

    Max. 20" steel with max. 3" Glass Fiber insulation

    English

  • F-A-1037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • W-J-0007

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 36" blank opening

    English

    Download File [117.5 kB]
  • C-BJ-1046

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

  • C-BJ-7005

    (Firestop System Details / UL Detail Drawing)

    Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)

    English

  • F-A-1017

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [82.9 kB]
  • F-A-1014

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, 6" copper, conduit or 4" EMT pipe

    English

  • C-AJ-7122

    (Approval document / Penetration)

    Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")

    English

  • C-AJ-8148

    (Firestop System Details / UL Detail Drawing)

    HVAC line set (optional sleeve)

    English

  • C-AJ-7095

    (CAD/BIM Typicals / Auto CAD drawing file)

    Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")

    English

  • W-J-1028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")

    English

    Download File [202.8 kB]
  • C-BJ-1045

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [185.9 kB]
  • C-AJ-2420

    (Firestop System Details / UL Detail Drawing)

    Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")

    English

    Download File [172 kB]
  • C-BJ-1049

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)

    English

    Download File [115.5 kB]
  • W-J-0022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2-1/2" dia or 2" x 2" blank opening

    English

  • C-AJ-7104

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" sheet metal duct w/o damper (bottom side access)

    English

  • W-J-1020

    (Approval document / Penetration)

    Max. 4" steel, copper, conduit or EMT pipe

    English

  • C-AJ-2420

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")

    English

    Download File [356.5 kB]
  • C-AJ-8209

    (Approval document / Penetration)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [393.4 kB]
  • C-AJ-8107

    (Firestop System Details / UL Detail Drawing)

    Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)

    English

    Download File [211.4 kB]
  • F-A-1018

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit

    English

  • C-BJ-5013

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper with max. 1" glass fiber insulation

    English

  • W-J-0015

    (Firestop System Details / UL Detail Drawing)

    Max. area of opening - 240 sq. in. with max. dimension of 20"

    English

  • C-AJ-7111

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)

    English

  • C-AJ-7103

    (Approval document / Penetration)

    Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)

    English

  • C-AJ-8166

    (Approval document / Penetration)

    HVAC line set (optional sleeve) (bottom side access)

    English

  • F-A-1028

    (Approval document / Penetration)

    Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)

    English

  • C-AJ-8100

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated copper or cables (single or bundled) (AS varies)

    English

    Download File [233.4 kB]
  • C-BJ-4026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack (Telecom)

    English

    Download File [275.6 kB]
  • C-BJ-4025

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack (Telecom)

    English

    Download File [279.3 kB]
  • F-A-0012

    (Approval document / Penetration)

    Max. 30" x 12" or 12" diameter blank opening

    English

    Download File [78.9 kB]
  • C-AJ-8107

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" EMT or conduit, single or bundled cables, Max. 2" PVC Innerduct (AS varies)

    English

    Download File [254.6 kB]
  • C-AJ-8038

    (Approval document / Penetration)

    Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")

    English

  • W-J-1068

    (Approval document / Penetration)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve

    English

  • C-AJ-7104

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" sheet metal duct w/o damper (bottom side access)

    English

  • W-J-0010

    (Approval document / Penetration)

    Max. 4" blank opening (optional sleeve)

    English

  • W-J-0010

    (Firestop System Details / UL Detail Drawing)

    Max. 4" blank opening (optional sleeve)

    English

    Download File [103.9 kB]
  • C-BJ-1049

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)

    English

    Download File [219.4 kB]
  • C-BJ-5015

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • F-A-1037

    (Approval document / Penetration)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • F-A-1017

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [271.2 kB]
  • C-AJ-8110

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)

    English

    Download File [48.1 kB]
  • C-AJ-7103

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)

    English

  • W-J-1020

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, copper, conduit or EMT pipe

    English

  • C-BJ-1047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel or cast iron (2 hour T-rating)

    English

    Download File [187.3 kB]
  • C-BJ-1046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

  • W-J-0007

    (Approval document / Penetration)

    Max. 24" x 36" blank opening

    English

    Download File [187.2 kB]
  • W-J-1021

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 18" steel or max. 4" copper pipe

    English

  • C-AJ-7098

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 49" x 49" steel grease duct with 1-1/2" Firemaster® Fast Wrap manufactured by Thermal Ceramics

    English

  • C-AJ-7051

    (Approval document / Penetration)

    Max. 30" x 30" sheet metal duct w/o damper

    English

    Download File [322.8 kB]
  • C-BJ-8024

    (Approval document / Penetration)

    One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")

    English

  • F-A-1016

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)

    English

    Download File [273.8 kB]
  • C-BJ-5018

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • C-BJ-1047

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel or cast iron (2 hour T-rating)

    English

    Download File [41.2 kB]
  • W-J-0008

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 36" blank opening

    English

    Download File [32.3 kB]
  • C-AJ-7103

    (Firestop System Details / UL Detail Drawing)

    Max. 6" sheet metal duct w/o damper (bottom side access) (hollow core)

    English

  • C-AJ-8110

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 6" copper, steel conduit, or max. 4" EMT, Max. 2" Innerduct, Cable Tray, Large cables, (various cables) (AS varies)

    English

    Download File [253.7 kB]
  • C-AJ-8100

    (Approval document / Penetration)

    Insulated or non-insulated copper or cables (single or bundled) (AS varies)

    English

    Download File [149.1 kB]
  • C-AJ-7006

    (Approval document / Penetration)

    Max. 36" grease duct manufactured by Metal-Fab (AS=1")

    English

  • C-BJ-3032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cables (various) through Firestop Cable Transit

    English

    Download File [323.7 kB]
  • C-BJ-5006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" steel with max. 3" Glass Fiber insulation

    English

  • C-AJ-8099

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated copper or steel, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)

    English

  • C-BJ-1055

    (Approval document / Penetration)

    Max. 2" steel or cast iron

    English

  • C-BJ-8014

    (Approval document / Penetration)

    Cable Rack (Telecom)

    English

    Download File [39.9 kB]
  • C-BJ-1047

    (Approval document / Penetration)

    Max. 8" steel or cast iron (2 hour T-rating)

    English

    Download File [31.1 kB]
  • C-BJ-3031

    (Approval document / Penetration)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [117.2 kB]
  • W-J-0022

    (Firestop System Details / UL Detail Drawing)

    Max. 2-1/2" dia or 2" x 2" blank opening

    English

  • C-BJ-1037

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete

    English

  • C-BJ-1059

    (Firestop System Details / UL Detail Drawing)

    Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")

    English

  • C-BJ-5006

    (Firestop System Details / UL Detail Drawing)

    Max. 20" steel with max. 3" Glass Fiber insulation

    English

  • F-A-1022

    (Firestop System Details / UL Detail Drawing)

    Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5)

    English

    Download File [125.9 kB]
  • C-AJ-8100

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated copper or cables (single or bundled) (AS varies)

    English

    Download File [207 kB]
  • C-AJ-6036

    (Approval document / Penetration)

    Electrical busway (23" x 4-1/2", qty 1) or (11-1/4" x 4-1/2", qty 2) (AS=1/4" to 5-3/4")

    English

    Download File [27.5 kB]
  • C-AJ-8095

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [39.6 kB]
  • C-AJ-7111

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 30" sheet metal duct w/o damper (2-1/2" concrete)

    English

  • W-J-0015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. area of opening - 240 sq. in. with max. dimension of 20"

    English

  • C-BJ-1055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel or cast iron

    English

  • C-BJ-1037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (Sleeve Optional) - Hebel Concrete

    English

  • W-J-1041

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • C-AJ-2420

    (Approval document / Penetration)

    Nominal 10" or 12" PVC or CPVC (c,v) (AS=1/4" to 1")

    English

    Download File [88 kB]
  • C-AJ-7084

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" spiral wound sheet metal duct or max. 12" sheet metal duct (min 28 ga)

    English

    Download File [186.4 kB]
  • F-A-0005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank CP 680-P (2-1/2" Concrete)

    English

    Download File [210.9 kB]
  • C-BJ-0022

    (Approval document / Penetration)

    Max. 24" x 12" unsleeved opening

    English

    Download File [303.8 kB]
  • C-AJ-8166

    (Firestop System Details / UL Detail Drawing)

    HVAC line set (optional sleeve) (bottom side access)

    English

  • C-AJ-7030

    (Approval document / Penetration)

    Insulated Flamebar BW11 Coated Fire Rated Ductwork

    English

    Download File [149.8 kB]
  • C-BJ-8010

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, steel conduit, or max. 4" EMT, optional glass fiber insulation, Max. 4" cable bundle

    English

    Download File [40.8 kB]
  • C-BJ-1045

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [119.2 kB]
  • C-AJ-8058

    (Approval document / Penetration)

    Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)

    English

  • W-J-0006

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 15" blank opening

    English

    Download File [176.7 kB]
  • C-AJ-7095

    (Firestop System Details / UL Detail Drawing)

    Steel air duct with 1-1/2" thick FireMaster FireWrap+ manufactured by Thermal Ceramics (AS=3")

    English

  • C-BJ-5018

    (Approval document / Penetration)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • F-A-1029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe

    English

  • C-AJ-8148

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set (optional sleeve)

    English

  • C-BJ-3024

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

  • C-BJ-5015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, or copper with 1" glass fiber insulation (bottom side access)

    English

  • C-AJ-8095

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe

    English

    Download File [178.4 kB]
  • C-AJ-7123

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")

    English

  • C-AJ-8044

    (Approval document / Penetration)

    Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")

    English

  • W-J-1021

    (Firestop System Details / UL Detail Drawing)

    Max. 18" steel or max. 4" copper pipe

    English

  • F-A-0006

    (Approval document / Penetration)

    Blank CP 680-P

    English

    Download File [290.3 kB]
  • C-BJ-3024

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

  • C-BJ-5013

    (Approval document / Penetration)

    Max. 4" steel or copper with max. 1" glass fiber insulation

    English

  • W-J-1042

    (Approval document / Penetration)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • C-BJ-4025

    (Firestop System Details / UL Detail Drawing)

    Cable Rack (Telecom)

    English

    Download File [199.2 kB]
  • F-A-1028

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, 6" copper, conduit or 4" EMT (Sleeve Optional)

    English

  • C-AJ-8096

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [155.7 kB]
  • C-AJ-7122

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" steel air or grease duct with Duct Wrap by Unifrax (AS=1-1/4" to 1-3/4")

    English

  • W-J-0008

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 36" blank opening

    English

    Download File [286.2 kB]
  • C-AJ-8180

    (Approval document / Penetration)

    Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)

    English

    Download File [32.8 kB]
  • C-BJ-0022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" unsleeved opening

    English

    Download File [147.8 kB]
  • W-J-1058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • C-AJ-7046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 32" x 32" sheet metal duct w/o damper

    English

  • W-J-1028

    (Approval document / Penetration)

    Max. 10" steel, max. 4" copper, conduit or EMT pipe (AS=1/2" to 7/8")

    English

    Download File [239 kB]
  • C-AJ-8178

    (Firestop System Details / UL Detail Drawing)

    HVAC line set w/ PVC drain

    English

    Download File [43.5 kB]
  • F-A-0012

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 12" or 12" diameter blank opening

    English

  • C-BJ-8014

    (Firestop System Details / UL Detail Drawing)

    Cable Rack (Telecom)

    English

    Download File [176.3 kB]
  • C-BJ-1034

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, conduit or EMT pipe

    English

  • W-J-0022

    (Approval document / Penetration)

    Max. 2-1/2" dia or 2" x 2" blank opening

    English

  • C-AJ-7051

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 30" sheet metal duct w/o damper

    English

    Download File [119.9 kB]
  • C-AJ-8208

    (Approval document / Penetration)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [553.6 kB]
  • F-A-1023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" and 3" Steel conduit or EMT

    English

    Download File [217.6 kB]
  • C-AJ-7123

    (Approval document / Penetration)

    Max. 24" x 24" steel air or grease duct with Duct Wrap by Unifrax (AS=1")

    English

  • C-AJ-7140

    (Approval document / Penetration)

    Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")

    English

    Download File [357.2 kB]
  • C-AJ-8177

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated metallic pipes, conduits, non-metallic pipes cables, and sheet metal duct

    English

    Download File [285.9 kB]
  • C-BJ-7005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" dia sheet metal duct w/o damper (8" prescast concrete)

    English

  • C-AJ-8058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple insulated and non-insulated copper pipe, max. 1-1/2" PVC (open or closed) and cables (2-1/2" concrete)

    English

  • C-AJ-7145

    (Firestop System Details / UL Detail Drawing)

    Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation

    English

  • W-J-1041

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • W-J-1021

    (Approval document / Penetration)

    Max. 18" steel or max. 4" copper pipe

    English

  • F-A-1037

    (Firestop System Details / UL Detail Drawing)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • C-AJ-7145

    (Approval document / Penetration)

    Max. 60" x 36" sheet metal duct with 2" glass fiber duct insulation

    English

  • C-AJ-8081

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel tube and cables (AS varies)

    English

  • W-J-0015

    (Approval document / Penetration)

    Max. area of opening - 240 sq. in. with max. dimension of 20"

    English

  • C-AJ-7140

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 38" Fyreguard Grease Duct, mfg by Schebler Co (AS=1/2" to 1-1/2")

    English

    Download File [286.2 kB]
  • W-J-0006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 15" blank opening

    English

    Download File [152.8 kB]
  • C-BJ-8027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Single HVAC Line set (8" hollow core)

    English

  • C-AJ-8148

    (Approval document / Penetration)

    HVAC line set (optional sleeve)

    English

  • F-A-1029

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit or max. 4" EMT pipe

    English

  • C-AJ-8210

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [252.5 kB]
  • W-J-1068

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve

    English

  • C-AJ-7029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Flamebar BW 11 Fire Rated Duct Work

    English

    Download File [253.9 kB]
  • F-A-0014

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank CP 680-M or CP 680-P

    English

    Download File [215 kB]
  • W-J-1041

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • C-AJ-8041

    (Approval document / Penetration)

    Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)

    English

  • C-BJ-8024

    (Firestop System Details / UL Detail Drawing)

    One or more HVAC line sets in 32" x 8" opening (6" concrete) (AS=1/2" to 12")

    English

  • W-J-1088

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • W-J-0008

    (Approval document / Penetration)

    Max. 24" x 36" blank opening

    English

    Download File [67.9 kB]
  • C-AJ-7029

    (Firestop System Details / UL Detail Drawing)

    Flamebar BW 11 Fire Rated Duct Work

    English

    Download File [184.1 kB]
  • F-A-1018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit

    English

  • C-AJ-8180

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated copper or steel, cables (single or bundled), or flexible steel conduit (AS Varies)

    English

    Download File [163 kB]
  • C-BJ-8013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack (Telecom)

    English

    Download File [304.6 kB]
  • F-A-0005

    (Approval document / Penetration)

    Blank CP 680-P (2-1/2" Concrete)

    English

    Download File [223.3 kB]
  • C-AJ-8044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated and non-insulated steel and copper pipe (max. 1" steel/copper) (AS=3/8" to 2")

    English

  • C-AJ-8041

    (Firestop System Details / UL Detail Drawing)

    Multiple insulated and non-insulated steel and copper pipes (max. 3" steel/copper) (AS varies)

    English

  • W-J-0006

    (Approval document / Penetration)

    Max. 30" x 15" blank opening

    English

    Download File [20 kB]
  • W-J-1058

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • C-AJ-7046

    (Approval document / Penetration)

    Max. 32" x 32" sheet metal duct w/o damper

    English

  • W-J-1068

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in sleeve

    English

  • C-BJ-1059

    (Approval document / Penetration)

    Multiple max. 1" flexible steel conduits or gas piping (Hollow Core) (AS=0" to 1-1/2")

    English

  • C-AJ-8056

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled) (AS varies)

    English

    Download File [43.1 kB]
  • C-BJ-8020

    (Approval document / Penetration)

    Multiple bundle of metallic pipes and cables

    English

  • C-AJ-8038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple insulated and non-insulated copper pipes (max. 3") (AS=1" to 2-1/4")

    English

  • C-BJ-8020

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple bundle of metallic pipes and cables

    English

  • C-AJ-8208

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [226.4 kB]
  • C-AJ-6042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Electrical busway through concrete floor/wall or block wall

    English

    Download File [110.7 kB]
  • F-A-1016

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit, or max. 4" EMT pipe (2-1/2" Concrete)

    English

    Download File [453.4 kB]
  • C-AJ-6042

    (Firestop System Details / UL Detail Drawing)

    Electrical busway through concrete floor/wall or block wall

    English

    Download File [124.2 kB]
  • C-BJ-1034

    (Approval document / Penetration)

    Max. 4" steel, conduit or EMT pipe

    English

  • C-BJ-1049

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit, or EMT (multiple pipes)

    English

    Download File [30.4 kB]
  • C-AJ-8209

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through concrete floor/wall or block wall

    English

    Download File [176.1 kB]
  • F-A-1066

    (Firestop System Details / UL Detail Drawing)

    Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)

    English

    Download File [124.8 kB]
  • F-A-5009

    (Approval document / Penetration)

    Max. 10" steel pipe with 2" glass fiber insulation

    English

  • F-A-3022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [246.8 kB]
  • F-A-1134

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")

    English

  • F-C-1106

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [74.6 kB]
  • F-C-1106

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [124.4 kB]
  • F-A-5019

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")

    English

  • F-C-1147

    (Approval document / Penetration)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [370.4 kB]
  • F-A-8004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel tube and cables

    English

  • F-A-5032

    (Firestop System Details / UL Detail Drawing)

    Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)

    English

  • F-C-1009

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")

    English

    Download File [91.2 kB]
  • F-C-1135

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings

    English

    Download File [144.3 kB]
  • F-A-5046

    (Approval document / Penetration)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber

    English

    Download File [33 kB]
  • F-A-3022

    (Approval document / Penetration)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [323.7 kB]
  • F-A-1137

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)

    English

  • F-A-2156

    (Approval document / Penetration)

    Max. 2" PVC shower drain fitting with CP 681 75/2"N Firestop Drain Flange or CP 681 SD-FD

    English

  • F-A-1038

    (Firestop System Details / UL Detail Drawing)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • F-B-4006

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" x 2" cable rack

    English

    Download File [391.7 kB]
  • F-A-1091

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper

    English

    Download File [146 kB]
  • F-A-1105

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT

    English

  • F-A-3012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)

    English

  • F-A-1127

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)

    English

  • F-A-5036

    (Approval document / Penetration)

    Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)

    English

  • F-C-3094

    (Firestop System Details / UL Detail Drawing)

    Multiple SER cables in slotted opening

    English

  • F-C-1009

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")

    English

    Download File [152.4 kB]
  • F-A-5017

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)

    English

    Download File [147.8 kB]
  • F-B-5003

    (Approval document / Penetration)

    Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")

    English

  • F-A-1127

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)

    English

  • F-A-8027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)

    English

  • F-A-1134

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")

    English

  • F-A-5021

    (Approval document / Penetration)

    Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation

    English

  • F-A-6002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")

    English

  • F-A-5042

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron or max. 4" copper with 1-1/2" glass fiber insulation (AS varies)

    English

  • F-C-1147

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [124.7 kB]
  • F-A-5019

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")

    English

  • F-B-4006

    (Approval document / Penetration)

    Max. 20" x 2" cable rack

    English

    Download File [46.8 kB]
  • F-B-1026

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [286.2 kB]
  • F-A-5009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel pipe with 2" glass fiber insulation

    English

  • F-B-5004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation

    English

    Download File [409.8 kB]
  • F-A-1108

    (Firestop System Details / UL Detail Drawing)

    Max. 3" steel or cast iron with closet flange (AS=min 3/8")

    English

  • F-C-3044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (AS=3/4")

    English

  • F-A-1194

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [443.1 kB]
  • F-A-5032

    (Approval document / Penetration)

    Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)

    English

  • F-A-1108

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" steel or cast iron with closet flange (AS=min 3/8")

    English

  • F-A-1105

    (Approval document / Penetration)

    Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT

    English

  • F-C-3071

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [196.2 kB]
  • F-B-5005

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber

    English

    Download File [270 kB]
  • F-A-5015

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)

    English

    Download File [148 kB]
  • F-A-3019

    (Approval document / Penetration)

    Cable bundle (various cables) (Unique Sleeve)

    English

    Download File [76.1 kB]
  • F-B-1010

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)

    English

    Download File [257.3 kB]
  • F-C-1147

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [244.3 kB]
  • F-A-1066

    (Approval document / Penetration)

    Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)

    English

    Download File [343.5 kB]
  • F-C-0002

    (Approval document / Penetration)

    Max. 2" dia blank opening

    English

    Download File [332.4 kB]
  • F-A-6002

    (Firestop System Details / UL Detail Drawing)

    Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")

    English

  • F-B-1009

    (Firestop System Details / UL Detail Drawing)

    Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)

    English

    Download File [97.4 kB]
  • F-A-5016

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation

    English

    Download File [451.5 kB]
  • F-C-1059

    (Approval document / Penetration)

    Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit

    English

  • F-C-0002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" dia blank opening

    English

    Download File [222.9 kB]
  • F-A-1127

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit, EMT, or 1" flexible steel conduit (one or more)

    English

  • F-C-3074

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [158.3 kB]
  • F-A-3012

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)

    English

  • F-C-1142

    (Approval document / Penetration)

    Max. 1" copper, steel, cast iron, steel conduit, or EMT

    English

  • F-A-1105

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, cast iron, 6" steel conduit, or 4" EMT

    English

  • F-A-4003

    (Approval document / Penetration)

    Cable Tray

    English

  • F-C-3012

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

  • F-A-5015

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)

    English

    Download File [148.9 kB]
  • F-B-5003

    (Firestop System Details / UL Detail Drawing)

    Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")

    English

  • F-A-4003

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

  • F-C-1135

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings

    English

    Download File [269.1 kB]
  • F-A-5032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" copper, steel or cast iron with 1" glass fiber or ab/pvc pipe insulation (max qty 3)

    English

  • F-A-8004

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel tube and cables

    English

  • F-A-5018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation

    English

    Download File [581.4 kB]
  • F-A-6002

    (Approval document / Penetration)

    Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")

    English

  • F-C-1059

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit

    English

  • F-A-1134

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit or EMT (up against a wall) (AS = 0" to 1-1/2")

    English

  • F-A-3033

    (Approval document / Penetration)

    Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)

    English

    Download File [78.9 kB]
  • F-A-3022

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (PW Sleeve)

    English

    Download File [150.2 kB]
  • F-A-1066

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple 1-1/2" steel pipe, steel conduit, EMT, or max. 1" Copper (Max. Qty 4)

    English

    Download File [222.7 kB]
  • F-A-7018

    (Approval document / Penetration)

    Max. 6" dia sheet metal duct w/o damper

    English

    Download File [317.2 kB]
  • F-A-1051

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" Copper, brass or cast iron waste/overflow fittings

    English

    Download File [117.7 kB]
  • F-A-5042

    (Approval document / Penetration)

    Max. 8" steel, cast iron or max. 4" copper with 1-1/2" glass fiber insulation (AS varies)

    English

  • F-A-3033

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)

    English

    Download File [134.7 kB]
  • F-A-2156

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC shower drain (System tested to 50 Pa)

    English

    Download File [371.8 kB]
  • F-A-1135

    (Firestop System Details / UL Detail Drawing)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)

    English

  • F-C-1106

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [217.2 kB]
  • F-A-8012

    (Approval document / Penetration)

    Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening

    English

  • F-A-5019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper pipe with max. 3/4" thick AB/PVC insulation (AS = 0" to 1-3/8")

    English

  • F-A-8016

    (Firestop System Details / UL Detail Drawing)

    Multiple HVAC Line Set

    English

    Download File [132.8 kB]
  • F-B-5004

    (Approval document / Penetration)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation

    English

    Download File [36.5 kB]
  • F-A-1128

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [31.5 kB]
  • F-A-8012

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening

    English

  • F-A-8023

    (Approval document / Penetration)

    Multiple bundle consisting of steel pipe, ENT, cable bundle

    English

    Download File [149.1 kB]
  • F-A-5021

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation

    English

  • F-A-5018

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation

    English

    Download File [95.4 kB]
  • F-C-1134

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" cast iron closet flange with cast iron fittings

    English

    Download File [223.4 kB]
  • F-C-3012

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

  • F-A-1137

    (Firestop System Details / UL Detail Drawing)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)

    English

  • F-A-1119

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")

    English

  • F-A-3034

    (Firestop System Details / UL Detail Drawing)

    Nom. 4/C No 500 kcmill TEK Cable

    English

    Download File [86.2 kB]
  • F-A-1038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • F-B-4006

    (Firestop System Details / UL Detail Drawing)

    Max. 20" x 2" cable rack

    English

    Download File [191.3 kB]
  • F-A-1194

    (Approval document / Penetration)

    English

    Download File [94.2 kB]
  • F-B-1009

    (Approval document / Penetration)

    Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)

    English

    Download File [73.5 kB]
  • F-A-1091

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper

    English

    Download File [281.2 kB]
  • F-A-3019

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Unique Sleeve)

    English

    Download File [167.4 kB]
  • F-C-3094

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple SER cables in slotted opening

    English

  • F-A-1128

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [44 kB]
  • F-A-1106

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit, or EMT

    English

    Download File [146.7 kB]
  • F-C-1009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit or EMT pipe (AS=0" to 1")

    English

    Download File [346.7 kB]
  • F-A-5017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)

    English

    Download File [327.5 kB]
  • F-A-8027

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)

    English

  • F-A-3012

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve optional) (2-1/2" concrete over metal deck)

    English

  • F-B-1026

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [34.5 kB]
  • F-A-7018

    (Firestop System Details / UL Detail Drawing)

    Max. 6" dia sheet metal duct w/o damper

    English

    Download File [139 kB]
  • F-A-5036

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)

    English

  • F-C-1142

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" copper, steel, cast iron, steel conduit, or EMT

    English

  • F-B-1026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [380.4 kB]
  • F-A-5009

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel pipe with 2" glass fiber insulation

    English

  • F-B-5004

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber insulation

    English

    Download File [280.2 kB]
  • F-C-3044

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (AS=3/4")

    English

  • F-A-1051

    (Approval document / Penetration)

    Max. 2" Copper, brass or cast iron waste/overflow fittings

    English

    Download File [36.4 kB]
  • F-A-1106

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit, or EMT

    English

    Download File [245.1 kB]
  • F-A-3007

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

    Download File [201.2 kB]
  • F-C-3071

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [277.1 kB]
  • F-A-1119

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")

    English

  • F-C-3071

    (Approval document / Penetration)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [92.8 kB]
  • F-A-5016

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation

    English

    Download File [95.3 kB]
  • F-A-5015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)

    English

    Download File [313.8 kB]
  • F-B-1010

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)

    English

    Download File [160.5 kB]
  • F-A-1137

    (Approval document / Penetration)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (concrete floor over metal deck) (w/ Thermal Ceramics)

    English

  • F-C-1135

    (Approval document / Penetration)

    Max. 1-1/2" cast iron P-trap with PVC, ABS, or brass bathtub waste/overflow fittings

    English

    Download File [347.4 kB]
  • F-C-3094

    (Approval document / Penetration)

    Multiple SER cables in slotted opening

    English

  • F-A-5046

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber

    English

    Download File [284.2 kB]
  • F-A-5046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron or copper with 3/4" or 1" ABPVC / 1", 1-1/2" or 2" of glass fiber

    English

    Download File [491.3 kB]
  • F-B-1009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nom. 3" or 4" steel or cast iron with aerator fitting (Sovent) (5" or 6-1/2" concrete)

    English

    Download File [211 kB]
  • F-A-5016

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation

    English

    Download File [104.7 kB]
  • F-C-0002

    (Firestop System Details / UL Detail Drawing)

    Max. 2" dia blank opening

    English

    Download File [107.7 kB]
  • F-C-3074

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [153.3 kB]
  • F-A-1119

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT (optional sleeve) (2-1/2" concrete) (AS=0" to 2")

    English

  • F-A-3007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

    Download File [291.9 kB]
  • F-C-3012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

  • F-A-1106

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit, or EMT

    English

    Download File [177 kB]
  • F-B-5003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple 3" copper, steel, cast iron (max. qty = 5) with 1" glass fiber or AB/PVC insulation (6" concrete) (AS=1/4" to 6")

    English

  • F-A-4003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

  • F-B-1029

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit, copper or EMT

    English

    Download File [281.9 kB]
  • F-A-8004

    (Approval document / Penetration)

    Max. 6" steel tube and cables

    English

  • F-C-1142

    (Firestop System Details / UL Detail Drawing)

    Max. 1" copper, steel, cast iron, steel conduit, or EMT

    English

  • F-A-5036

    (Firestop System Details / UL Detail Drawing)

    Max. 1-1/2" steel, cast iron or copper with 1" glass fiber or 3/4" AB/PVC (max qty = 5)

    English

  • F-C-3074

    (Approval document / Penetration)

    Cable bundle (various cables) (AS=0" to 1")

    English

    Download File [87.7 kB]
  • F-A-7018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" dia sheet metal duct w/o damper

    English

    Download File [123.7 kB]
  • F-A-1135

    (Approval document / Penetration)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)

    English

  • F-A-8023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple bundle consisting of steel pipe, ENT, cable bundle

    English

    Download File [248.1 kB]
  • F-A-5018

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation

    English

    Download File [104.3 kB]
  • F-A-1038

    (Approval document / Penetration)

    Tub Box with max. 1-1/2" brass waste/overflow fittings

    English

  • F-C-1059

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, conduit, max. 4" EMT, or max. 2" flexible steel conduit

    English

  • F-A-5017

    (Approval document / Penetration)

    Max. 4" steel or copper pipe with max. 2" thickness glass-fiber insulation (2-1/2" concrete)

    English

    Download File [148.1 kB]
  • F-C-3044

    (Approval document / Penetration)

    Cable bundle (various cables) (AS=3/4")

    English

  • F-A-1128

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit, copper or 4" EMT

    English

    Download File [480.5 kB]
  • F-A-3019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Unique Sleeve)

    English

    Download File [327.1 kB]
  • F-A-1091

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit, max. 4" EMT or max. 2" copper

    English

    Download File [207.1 kB]
  • F-A-1051

    (Firestop System Details / UL Detail Drawing)

    Max. 2" Copper, brass or cast iron waste/overflow fittings

    English

    Download File [161.2 kB]
  • F-A-8027

    (Approval document / Penetration)

    Insulated or non-insulated metallic pipes, cable bundles, steel conduits (max. 24" x 8" opening)

    English

  • F-A-3033

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (2-1/2" concrete) (2-1/2" concrete floor)

    English

    Download File [130.6 kB]
  • F-A-1135

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" x 12" x 10" cast iron floor sink with 4" cast iron drain (w/ Thermal Ceramics)

    English

  • F-A-1108

    (Approval document / Penetration)

    Max. 3" steel or cast iron with closet flange (AS=min 3/8")

    English

  • F-C-1134

    (Firestop System Details / UL Detail Drawing)

    Max. 4" cast iron closet flange with cast iron fittings

    English

    Download File [100.6 kB]
  • F-A-5021

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or max. 6" copper pipe with nom. 1-1/2" thickness glass-fiber insulation

    English

  • F-A-3007

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

    Download File [147.4 kB]
  • F-B-1010

    (Approval document / Penetration)

    Max. 6" steel or cast iron (2-hour T-rating) (6" concrete floor)

    English

    Download File [144.4 kB]
  • F-A-8012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated metallic pipes, conduits and cables (single or bundled) in max. 30" x 48" opening

    English

  • W-J-4050

    (Firestop System Details / UL Detail Drawing)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [383.5 kB]
  • W-J-3143

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [127.3 kB]
  • F-E-3012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple SER cables in slotted opening

    English

  • F-E-5013

    (Approval document / Penetration)

    Max. 2" steel or copper pipe with max. 1-1/2" glass fiber

    English

  • W-J-1226

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, steel conduit or EMT

    English

    Download File [255.8 kB]
  • W-J-1095

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit

    English

  • F-C-5036

    (Approval document / Penetration)

    Max. 2" copper, or steel pipe with max. 1-1/2" glass fiber

    English

  • W-J-2229

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" PEX (bundled) (c,v) through CP 653 Speed Sleeve

    English

  • W-J-5150

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • F-C-7037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" sheet metal duct with 1-1/2" thick duct wrap

    English

  • F-C-8032

    (Approval document / Penetration)

    Double HVAC Line Set (no pvc drain)

    English

    Download File [30.6 kB]
  • W-J-4060

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray (36" x 6")

    English

    Download File [195.5 kB]
  • W-J-5041

    (Approval document / Penetration)

    Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")

    English

  • W-J-1221

    (Firestop System Details / UL Detail Drawing)

    Multiple Max. 1" Flexible steel conduits

    English

  • W-J-1214

    (Firestop System Details / UL Detail Drawing)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-J-3111

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through Unique Threaded Sleeve

    English

    Download File [21.4 kB]
  • W-J-4050

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [1.1 MB]
  • F-C-7043

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [248.4 kB]
  • F-A-3071

    (Approval document / Penetration)

    English

    Download File [104.9 kB]
  • F-C-5065

    (Firestop System Details / UL Detail Drawing)

    Max. 4" copper, cast iron or steel pipe with 3/4" AB/PVC insulation

    English

    Download File [222.4 kB]
  • F-E-1018

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [100.9 kB]
  • F-C-5065

    (Approval document / Penetration)

    Max. 4" copper, cast iron or steel pipe with " AB/PVC insulation

    English

    Download File [89 kB]
  • W-J-1201

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [20.2 kB]
  • W-J-3168

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve

    English

    Download File [89.1 kB]
  • W-J-4027

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [245.7 kB]
  • W-J-1116

    (Approval document / Penetration)

    Max. 2" steel conduit or EMT (one or more)

    English

    Download File [32.1 kB]
  • W-J-3168

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-J-4048

    (Firestop System Details / UL Detail Drawing)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [165.6 kB]
  • W-J-1221

    (Approval document / Penetration)

    Multiple Max. 1" Flexible steel conduits

    English

  • W-J-4050

    (Approval document / Penetration)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [109.4 kB]
  • W-J-5150

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • W-J-4060

    (Firestop System Details / UL Detail Drawing)

    Cable Tray (36" x 6")

    English

    Download File [134.6 kB]
  • W-J-3111

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through unique threaded sleeve

    English

    Download File [324.6 kB]
  • F-E-5004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel or copper pipe with max. 3/4" AB/PVC

    English

  • W-J-1221

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple Max. 1" Flexible steel conduits

    English

  • W-J-3050

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeved)

    English

  • W-J-1124

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [22 kB]
  • W-J-1123

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [102.4 kB]
  • W-J-5067

    (Approval document / Penetration)

    Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)

    English

  • W-J-5140

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)

    English

  • F-C-7025

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper

    English

    Download File [150.3 kB]
  • W-J-5003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation

    English

  • W-J-3074

    (Firestop System Details / UL Detail Drawing)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [206.8 kB]
  • W-J-1226

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, steel conduit or EMT

    English

    Download File [110.1 kB]
  • W-J-1202

    (Firestop System Details / UL Detail Drawing)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • W-J-4048

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [256.7 kB]
  • F-C-7036

    (Approval document / Penetration)

    Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics

    English

  • F-C-8044

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")

    English

  • W-J-3189

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

  • W-J-4029

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [215.5 kB]
  • W-J-1095

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit

    English

  • W-J-5140

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)

    English

  • W-J-5003

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation

    English

  • W-J-3036

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [247.8 kB]
  • F-A-3071

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [545 kB]
  • F-C-7013

    (Approval document / Penetration)

    Max. 4" diameter sheet metal duct w/o damper (min 28Ga)

    English

  • F-E-8008

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC Line Set

    English

  • W-J-1214

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-J-3196

    (Approval document / Penetration)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [106 kB]
  • W-J-4059

    (Approval document / Penetration)

    Cable Tray

    English

  • W-J-1128

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT

    English

    Download File [105.1 kB]
  • W-J-4029

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [79.9 kB]
  • W-J-3167

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve

    English

    Download File [89.7 kB]
  • W-J-5134

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [137.8 kB]
  • F-E-1018

    (Approval document / Penetration)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [76.8 kB]
  • W-J-1193

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)

    English

  • W-J-5041

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")

    English

  • F-C-5066

    (Approval document / Penetration)

    Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber

    English

    Download File [86.1 kB]
  • W-J-1193

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)

    English

  • W-J-3168

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-J-4029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [319.4 kB]
  • F-C-8026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Double HVAC Line Set (pvc drain)

    English

  • W-J-3110

    (Approval document / Penetration)

    Cable bundle (various cables) through Unique Split Sleeve

    English

    Download File [19.1 kB]
  • W-J-1095

    (Approval document / Penetration)

    Max. 1" flexible steel conduit

    English

  • F-C-7025

    (Firestop System Details / UL Detail Drawing)

    Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper

    English

    Download File [125.2 kB]
  • F-C-8032

    (Firestop System Details / UL Detail Drawing)

    Double HVAC Line Set (no pvc drain)

    English

    Download File [221.1 kB]
  • F-E-8008

    (Approval document / Penetration)

    HVAC Line Set

    English

  • W-J-5028

    (Approval document / Penetration)

    Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)

    English

  • F-C-8044

    (Approval document / Penetration)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")

    English

  • F-C-5037

    (Approval document / Penetration)

    Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation

    English

  • W-J-3196

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [448.1 kB]
  • W-J-4016

    (Firestop System Details / UL Detail Drawing)

    Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")

    English

    Download File [160.3 kB]
  • W-J-1123

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [213.8 kB]
  • W-J-5134

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [232.7 kB]
  • W-J-5041

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")

    English

  • W-J-5140

    (Approval document / Penetration)

    Max. 12" steel or 6" copper with max. 2" glass fiber (optional sleeve) (AS=0" to 1/2" for steel, 0" to 1-7/8" for copper)

    English

  • W-J-3074

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [249.2 kB]
  • F-E-5004

    (Approval document / Penetration)

    Max. 2" steel or copper pipe with max. 3/4" AB/PVC

    English

  • W-J-1202

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • F-E-3012

    (Firestop System Details / UL Detail Drawing)

    Multiple SER cables in slotted opening

    English

  • W-J-1174

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • F-E-3012

    (Approval document / Penetration)

    Multiple SER cables in slotted opening

    English

  • W-J-2242

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [319.1 kB]
  • W-J-5150

    (Approval document / Penetration)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • W-J-5067

    (Firestop System Details / UL Detail Drawing)

    Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)

    English

  • F-C-5065

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" copper, cast iron or steel pipe with 3/4" AB/PVC insulation

    English

    Download File [279.5 kB]
  • W-J-5057

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel pipe with max. 3" thick glass-fiber insulation

    English

    Download File [108.2 kB]
  • W-J-3036

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [130.1 kB]
  • W-J-1175

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

    Download File [174.6 kB]
  • W-J-3189

    (Firestop System Details / UL Detail Drawing)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

  • W-J-4016

    (CAD/BIM Typicals / Auto CAD drawing file)

    Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")

    English

    Download File [317 kB]
  • F-C-8038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")

    English

    Download File [310.6 kB]
  • F-C-5004

    (Approval document / Penetration)

    Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)

    English

  • F-C-8026

    (Approval document / Penetration)

    Double HVAC Line Set (pvc drain)

    English

  • W-J-5042

    (Approval document / Penetration)

    Max. 12" steel or 6" copper with 2" glass-fiber insulation

    English

  • F-C-7042

    (Firestop System Details / UL Detail Drawing)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [123.6 kB]
  • W-J-3092

    (Approval document / Penetration)

    Cable bundle (various cables) (PVC Sleeve)

    English

    Download File [239.3 kB]
  • F-E-1018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")

    English

    Download File [330.1 kB]
  • W-J-3198

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Firestop Retrofit Sleeve Kit

    English

    Download File [259.1 kB]
  • W-J-3199

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [206.4 kB]
  • W-J-1128

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT

    English

    Download File [22 kB]
  • W-J-5067

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" copper with max. 2" thick glass-fiber insulation (Shaft Wall)

    English

  • F-C-5004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)

    English

  • W-J-1202

    (Approval document / Penetration)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • W-J-5057

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel pipe with max. 3" thick glass-fiber insulation

    English

    Download File [213.9 kB]
  • W-J-3060

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeved) (AS=0" to 1")

    English

    Download File [332 kB]
  • W-J-3188

    (Approval document / Penetration)

    Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")

    English

    Download File [81.7 kB]
  • W-J-4016

    (Approval document / Penetration)

    Aluminum Spine Cable Tray (18" x 6") (AS=1" to 4-1/2")

    English

    Download File [316.3 kB]
  • W-J-1193

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)

    English

  • W-J-1215

    (Approval document / Penetration)

    Max. 3" steel, cast iron, steel conduit or EMT

    English

    Download File [81.6 kB]
  • F-E-7008

    (Firestop System Details / UL Detail Drawing)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [102.1 kB]
  • F-E-5004

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel or copper pipe with max. 3/4" AB/PVC

    English

  • W-J-1191

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple max. 2" steel, steel conduits, or EMT

    English

    Download File [214.9 kB]
  • W-J-3050

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeved)

    English

  • W-J-3060

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeved) (AS=0" to 1")

    English

    Download File [80.8 kB]
  • W-J-5058

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation

    English

    Download File [256.2 kB]
  • F-C-5036

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" copper, or steel pipe with max. 1-1/2" glass fiber

    English

  • W-J-5066

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)

    English

  • W-J-2241

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [137.4 kB]
  • W-J-1123

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [74.6 kB]
  • W-J-1168

    (Firestop System Details / UL Detail Drawing)

    Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT

    English

  • W-J-3198

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through Firestop Retrofit Sleeve Kit

    English

    Download File [40.6 kB]
  • W-J-5066

    (Approval document / Penetration)

    Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)

    English

  • W-J-3199

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [408.3 kB]
  • F-C-7055

    (Approval document / Penetration)

    Max. 4" sheet metal duct with 1" thick duct wrap

    English

  • F-E-1004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")

    English

  • W-J-1222

    (Approval document / Penetration)

    Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve

    English

    Download File [314.9 kB]
  • F-C-7043

    (Firestop System Details / UL Detail Drawing)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [94.4 kB]
  • W-J-1128

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, conduit, or max. 4" EMT

    English

    Download File [20.7 kB]
  • F-C-8044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")

    English

  • W-J-3200

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Cable Management Devices using Firestop Gangplate

    English

    Download File [651.1 kB]
  • W-J-3190

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (optional 45º angle)

    English

    Download File [92.7 kB]
  • W-J-1174

    (Firestop System Details / UL Detail Drawing)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • F-C-7042

    (Approval document / Penetration)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [405.2 kB]
  • W-J-2242

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [161.8 kB]
  • W-J-5058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation

    English

    Download File [119.5 kB]
  • F-C-5037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation

    English

  • W-J-5066

    (Firestop System Details / UL Detail Drawing)

    Max. 1" copper with max. 3/4" thick AB/PVC insulation (Shaft Wall)

    English

  • W-J-3036

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [83.5 kB]
  • W-J-1175

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

    Download File [247.6 kB]
  • F-E-5013

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel or copper pipe with max. 1-1/2" glass fiber

    English

  • F-E-8008

    (Firestop System Details / UL Detail Drawing)

    HVAC Line Set

    English

  • W-J-1174

    (Approval document / Penetration)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • W-J-2242

    (Approval document / Penetration)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [332.1 kB]
  • W-J-1201

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [196.9 kB]
  • F-C-7025

    (Approval document / Penetration)

    Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper

    English

    Download File [596.5 kB]
  • W-J-5042

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or 6" copper with 2" glass-fiber insulation

    English

  • W-J-3199

    (Approval document / Penetration)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [284.8 kB]
  • W-J-4060

    (Approval document / Penetration)

    Cable Tray (36" x 6")

    English

    Download File [342.5 kB]
  • W-J-1124

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [22 kB]
  • W-J-3200

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through Cable Management Devices using Firestop Gangplate

    English

    Download File [195.7 kB]
  • W-J-3197

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cables (various) through Firestop Cable Transit

    English

    Download File [305.3 kB]
  • W-J-4030

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [23.3 kB]
  • W-J-3143

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve optional)

    English

  • W-J-1191

    (Approval document / Penetration)

    Multiple max. 2" steel, steel conduits, or EMT

    English

    Download File [288.5 kB]
  • F-C-7036

    (Firestop System Details / UL Detail Drawing)

    Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics

    English

  • W-J-3111

    (Approval document / Penetration)

    English

    Download File [76.5 kB]
  • W-J-4049

    (Approval document / Penetration)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [70.8 kB]
  • F-C-8032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Double HVAC Line Set (no pvc drain)

    English

    Download File [163.9 kB]
  • W-J-4027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [234 kB]
  • F-C-8038

    (Approval document / Penetration)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")

    English

    Download File [556.8 kB]
  • W-J-3188

    (Firestop System Details / UL Detail Drawing)

    Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")

    English

    Download File [184.5 kB]
  • W-J-1191

    (Firestop System Details / UL Detail Drawing)

    Multiple max. 2" steel, steel conduits, or EMT

    English

    Download File [120.9 kB]
  • W-J-3050

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeved)

    English

  • W-J-5003

    (Approval document / Penetration)

    Max. 10" steel or max. 4" copper with 2" thick glass-fiber insulation

    English

  • W-J-5042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or 6" copper with 2" glass-fiber insulation

    English

  • F-E-1004

    (Approval document / Penetration)

    Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")

    English

  • F-C-5066

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber

    English

    Download File [156.8 kB]
  • W-J-2241

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [219 kB]
  • W-J-1168

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT

    English

  • F-E-3005

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various) (AS = 3/4")

    English

  • W-J-1210

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")

    English

  • W-J-5136

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [242.9 kB]
  • W-J-1089

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • F-E-7008

    (Approval document / Penetration)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [284.5 kB]
  • W-J-3092

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (PVC Sleeve)

    English

    Download File [83.7 kB]
  • W-J-5028

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)

    English

  • W-J-5136

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [246.3 kB]
  • W-J-1116

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel conduit or EMT (one or more)

    English

    Download File [213 kB]
  • W-J-4027

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [167.6 kB]
  • W-J-3190

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (optional 45º angle)

    English

    Download File [307.4 kB]
  • F-E-3005

    (Approval document / Penetration)

    Cable bundle (various) (AS = 3/4")

    English

  • F-C-8038

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS = 0" to 1-1/2")

    English

    Download File [237.9 kB]
  • F-C-7013

    (Firestop System Details / UL Detail Drawing)

    Max. 4" diameter sheet metal duct w/o damper (min 28Ga)

    English

  • W-J-4030

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [129.2 kB]
  • W-J-5057

    (Approval document / Penetration)

    Max. 10" steel pipe with max. 3" thick glass-fiber insulation

    English

    Download File [21.7 kB]
  • W-J-2229

    (Approval document / Penetration)

    Max. 1" PEX (bundled) (c,v) through CP 653 Speed Sleeve

    English

    Download File [83.8 kB]
  • W-J-3167

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-J-1201

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [23.9 kB]
  • W-J-3197

    (Approval document / Penetration)

    Cables (various) through Firestop Cable Transit

    English

    Download File [404.2 kB]
  • W-J-3061

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (shaft wall)

    English

  • W-J-5028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)

    English

  • F-C-7013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" diameter sheet metal duct w/o damper (min 28Ga)

    English

  • W-J-5136

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [114.1 kB]
  • W-J-3074

    (Approval document / Penetration)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [79.9 kB]
  • W-J-1124

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [106.7 kB]
  • W-J-1210

    (Approval document / Penetration)

    Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")

    English

  • W-J-1215

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" steel, cast iron, steel conduit or EMT

    English

  • W-J-3189

    (Approval document / Penetration)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

    Download File [121.6 kB]
  • W-J-3190

    (Approval document / Penetration)

    Cable bundle (various cables) (optional 45┬║ angle)

    English

    Download File [75.5 kB]
  • F-E-7008

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [250.5 kB]
  • W-J-3110

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through Unique Split Sleeve

    English

    Download File [147.8 kB]
  • W-J-4072

    (Firestop System Details / UL Detail Drawing)

    Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)

    English

    Download File [222.8 kB]
  • W-J-1214

    (Approval document / Penetration)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-J-3200

    (Approval document / Penetration)

    English

    Download File [122.7 kB]
  • W-J-1089

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • W-J-4030

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

    Download File [111 kB]
  • W-J-3188

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle through concrete wall or block wall assembly (concrete thickness minimum 5")

    English

    Download File [293.9 kB]
  • W-J-3061

    (Approval document / Penetration)

    Cable bundle (various cables) (shaft wall)

    English

  • F-E-1004

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast Iron, steel conduit or max. 4" EMT (AS=1/4" to 3/4")

    English

  • F-C-7037

    (Approval document / Penetration)

    Max. 4" sheet metal duct with 1-1/2" thick duct wrap

    English

  • F-C-5066

    (Firestop System Details / UL Detail Drawing)

    Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber

    English

    Download File [223.1 kB]
  • W-J-2230

    (Approval document / Penetration)

    Max. 2" ENT (one or more) through CP 653 Speed Sleeve

    English

    Download File [86.3 kB]
  • W-J-5058

    (Approval document / Penetration)

    Max. 10" steel, cast iron or 4" copper pipe with max. 3" thick glass-fiber insulation

    English

    Download File [23.7 kB]
  • F-C-7055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" sheet metal duct with 1" thick duct wrap

    English

  • W-J-4049

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [670.8 kB]
  • W-J-3112

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in Unique Split Sleeve or Threaded Sleeve

    English

    Download File [21.8 kB]
  • W-J-1210

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, 6" steel conduit, copper or 4" EMT (optional sleeve) (AS=0" to 1-7/8")

    English

  • W-J-1222

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve

    English

    Download File [134.1 kB]
  • W-J-3092

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (PVC Sleeve)

    English

    Download File [259.7 kB]
  • W-J-4072

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)

    English

    Download File [238 kB]
  • F-C-7036

    (CAD/BIM Typicals / Auto CAD drawing file)

    Steel Grease or Air Duct with Firemaster DuctWrap by Thermal Ceramics

    English

  • W-J-2230

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" ENT (one or more) through CP 653 Speed Sleeve

    English

  • W-J-1116

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel conduit or EMT (one or more)

    English

    Download File [119.6 kB]
  • F-C-7043

    (Approval document / Penetration)

    Max. 12" x 10" sheet metal duct (AS=0" to 1")

    English

    Download File [279 kB]
  • W-J-1226

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, steel conduit or EMT

    English

    Download File [288.9 kB]
  • F-C-5004

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, copper, conduit or EMT pipes with max. 1/2" glass fiber or max. 3/4" AB/PVC insulation (AS varies)

    English

  • W-J-1222

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron,6" steel conduit, or 4" copper in sheet meta sleeve

    English

    Download File [243.3 kB]
  • F-E-5013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel or copper pipe with max. 1-1/2" glass fiber

    English

  • W-J-3112

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in unique split sleeve or threaded sleeve

    English

    Download File [322.3 kB]
  • W-J-5134

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [303.7 kB]
  • W-J-4059

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

  • W-J-1168

    (Approval document / Penetration)

    Max. 24" steel, cast iron, max. 6" steel conduit, copper, or max. 4" EMT

    English

  • W-J-4049

    (Firestop System Details / UL Detail Drawing)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [374.2 kB]
  • W-J-2241

    (Approval document / Penetration)

    Cable bundle (various cables) through flexible nylon raceway (sleeve optional) (AS=0" to 3")

    English

    Download File [359 kB]
  • W-J-3167

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve

    English

  • F-E-3005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various) (AS = 3/4")

    English

  • W-J-4072

    (Approval document / Penetration)

    Cable tray through concrete wall or block wall assembly (concrete wall min. 5" thick)

    English

    Download File [80 kB]
  • F-C-5037

    (Firestop System Details / UL Detail Drawing)

    Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation

    English

  • W-J-1089

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT, or max. 2" flexible steel conduit (shaft wall)

    English

  • W-J-4048

    (Approval document / Penetration)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [385.1 kB]
  • W-J-3112

    (Approval document / Penetration)

    English

    Download File [78 kB]
  • W-J-1175

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" steel conduit, max. 4" copper or EMT

    English

    Download File [249.9 kB]
  • F-C-7042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [253.9 kB]
  • W-J-4059

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

  • W-J-3110

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through Unique Split Sleeve

    English

    Download File [21.5 kB]
  • W-J-1215

    (Firestop System Details / UL Detail Drawing)

    Max. 3" steel, cast iron, steel conduit or EMT

    English

  • W-L-0019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel pipe sleeve

    English

    Download File [296.3 kB]
  • W-L-1402

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [200.4 kB]
  • W-J-8017

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [349.8 kB]
  • W-L-0015

    (Approval document / Penetration)

    Max. 24" x 36" blank opening

    English

    Download File [37.3 kB]
  • W-L-1176

    (Firestop System Details / UL Detail Drawing)

    Max. 2" EMT or steel conduits (one or more)

    English

  • W-L-1462

    (Approval document / Penetration)

    Medical gas station outlet

    English

    Download File [84.7 kB]
  • W-L-1465

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve

    English

    Download File [579.6 kB]
  • W-L-1389

    (Firestop System Details / UL Detail Drawing)

    Multiple max. 2" steel, steel conduit, or EMT

    English

    Download File [104.5 kB]
  • W-L-0015

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 36" blank opening

    English

    Download File [366.5 kB]
  • W-L-1176

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" EMT or steel conduits (one or more)

    English

  • W-J-8022

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC Line Set

    English

  • W-J-8017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [446.7 kB]
  • W-L-1206

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-L-1111

    (Approval document / Penetration)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • W-L-1249

    (Approval document / Penetration)

    Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)

    English

    Download File [254.6 kB]
  • W-L-0019

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel pipe sleeve

    English

    Download File [145.7 kB]
  • W-L-1402

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [115.6 kB]
  • W-L-1170

    (Firestop System Details / UL Detail Drawing)

    Max. 6" copper, (sleeved)

    English

    Download File [23 kB]
  • W-L-1359

    (Approval document / Penetration)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • W-J-8009

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle

    English

    Download File [152.8 kB]
  • W-L-1392

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)

    English

  • W-L-1176

    (Approval document / Penetration)

    Max. 2" EMT or steel conduits (one or more)

    English

  • W-L-1389

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple max. 2" steel, steel conduit, or EMT

    English

    Download File [221.2 kB]
  • W-J-7021

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [243.3 kB]
  • W-L-0015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 36" blank opening

    English

    Download File [209.5 kB]
  • W-L-0030

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)

    English

  • W-J-8017

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [56.1 kB]
  • W-L-1408

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • W-J-7110

    (Approval document / Penetration)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-J-8022

    (Firestop System Details / UL Detail Drawing)

    HVAC Line Set

    English

  • W-L-1206

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-L-1406

    (Approval document / Penetration)

    Max. 8" steel, cast iron, steel conduit, max. 4" copper or EMT (UL Classified U336 or U366 Wall)

    English

  • W-L-1367

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT

    English

    Download File [178.6 kB]
  • W-J-8049

    (Approval document / Penetration)

    Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)

    English

    Download File [367.6 kB]
  • W-L-0013

    (Firestop System Details / UL Detail Drawing)

    Max. 4" threaded steel conduit with plastic or metal bushings

    English

    Download File [142.6 kB]
  • W-J-7038

    (Approval document / Penetration)

    Max. 6" sheet metal duct w/o damper (Shaft Wall)

    English

  • W-L-1170

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" copper, (sleeved)

    English

    Download File [248.8 kB]
  • W-J-8009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle

    English

    Download File [229.8 kB]
  • W-L-1243

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" aluminum or steel flexible conduit

    English

  • W-J-7021

    (Firestop System Details / UL Detail Drawing)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [153 kB]
  • W-L-0042

    (Approval document / Penetration)

    Blank opening through Gypsum wall assembly

    English

    Download File [309.2 kB]
  • W-L-0030

    (Firestop System Details / UL Detail Drawing)

    Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)

    English

  • W-L-1408

    (Firestop System Details / UL Detail Drawing)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • W-L-1164

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-J-7039

    (Approval document / Penetration)

    Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)

    English

  • W-J-8007

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)

    English

    Download File [220.1 kB]
  • W-J-8050

    (Approval document / Penetration)

    Multiple penetrating items through concrete block wall assembly (min. 5" thick)

    English

    Download File [82.8 kB]
  • W-L-1367

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT

    English

    Download File [318.6 kB]
  • W-L-1408

    (Approval document / Penetration)

    Multiple max. 4" steel, steel conduit, or EMT

    English

  • W-J-7029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation

    English

  • W-L-0013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" threaded steel conduit with plastic or metal bushings

    English

    Download File [366.8 kB]
  • W-L-0042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank opening through gypsum wall assembly

    English

    Download File [288.2 kB]
  • W-L-1412

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")

    English

  • W-L-1243

    (Firestop System Details / UL Detail Drawing)

    Max. 2" aluminum or steel flexible conduit

    English

  • W-J-8018

    (Approval document / Penetration)

    Cable bundle Cable Rack (Telecom) (various cables)

    English

    Download File [35 kB]
  • W-L-1359

    (Firestop System Details / UL Detail Drawing)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • W-L-1175

    (Approval document / Penetration)

    Max. 4" EMT or steel conduit

    English

    Download File [17.6 kB]
  • W-L-1402

    (Approval document / Penetration)

    Max. 4" steel, cast iron, steel conduit or EMT (one or more)

    English

    Download File [27.1 kB]
  • W-L-1304

    (Approval document / Penetration)

    Max. 4" steel, cast iron, conduit, or EMT

    English

    Download File [333.1 kB]
  • W-L-1164

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-J-8007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)

    English

    Download File [328.5 kB]
  • W-J-7112

    (Approval document / Penetration)

    Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/2" to 2")

    English

  • W-L-1248

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [155 kB]
  • W-J-7029

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation

    English

  • W-L-1252

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [379.9 kB]
  • W-L-0042

    (Firestop System Details / UL Detail Drawing)

    Blank opening through gypsum wall assembly

    English

    Download File [114.1 kB]
  • W-L-1148

    (Approval document / Penetration)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • W-L-1412

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")

    English

  • W-L-1111

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • W-J-7112

    (Firestop System Details / UL Detail Drawing)

    Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/4" to 3-1/2")

    English

  • W-L-1359

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" cast iron with "No-Hub" Connector

    English

  • W-J-7039

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)

    English

  • W-L-1441

    (Approval document / Penetration)

    Max. 3" steel, cast iron, steel conduit, or EMT

    English

    Download File [83.1 kB]
  • W-L-1441

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3" steel, cast iron, steel conduit, or EMT

    English

  • W-L-0014

    (Approval document / Penetration)

    Max. 24" x 36" blank opening

    English

    Download File [366.5 kB]
  • W-L-1248

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [44.6 kB]
  • W-L-1297

    (Firestop System Details / UL Detail Drawing)

    Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe

    English

    Download File [95.1 kB]
  • W-J-8049

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)

    English

    Download File [156.6 kB]
  • W-L-0018

    (Approval document / Penetration)

    Max. 4" steel pipe sleeve

    English

  • W-L-1464

    (Approval document / Penetration)

    Max. 1" single or bundled fledxible steel conduits

    English

  • W-L-1111

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, max. 6" copper, conduit or max. 4" EMT

    English

  • W-L-1243

    (Approval document / Penetration)

    Max. 2" aluminum or steel flexible conduit

    English

  • W-J-7112

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 100" x 100" sheet metal duct with 1-1/2" or 2" thick glass fiber duct insulation (AS=1/2" to 2")

    English

  • W-L-1252

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [235.5 kB]
  • W-J-7039

    (Firestop System Details / UL Detail Drawing)

    Max. 7" x 7" sheet metal duct w/o damper (Shaft Wall) (No angles)

    English

  • W-J-8044

    (Approval document / Penetration)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [426.6 kB]
  • W-L-1441

    (Firestop System Details / UL Detail Drawing)

    Max. 3" steel, cast iron, steel conduit, or EMT

    English

  • W-L-1465

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve

    English

    Download File [167.4 kB]
  • W-L-1110

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • W-L-1095

    (Firestop System Details / UL Detail Drawing)

    Max. 1" steel, conduit or EMT pipes (one or more)

    English

  • W-L-1248

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [370.8 kB]
  • W-L-1297

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe

    English

    Download File [374.5 kB]
  • W-J-8007

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, cable tray or cables (single or bundled)

    English

    Download File [513.6 kB]
  • W-J-7091

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 2-1/4")

    English

  • W-J-8049

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrants through concrete block wall assembly (minimum 7-5/8" thick)

    English

    Download File [302.6 kB]
  • W-L-1058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 16" steel, max. 4" copper, in wire mesh sleeve

    English

  • W-L-1464

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" single or bundled fledxible steel conduits

    English

  • W-L-1360

    (Approval document / Penetration)

    Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT

    English

  • W-L-1389

    (Approval document / Penetration)

    Multiple max. 2" steel, steel conduit, or EMT

    English

    Download File [312.5 kB]
  • W-L-1205

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-L-1252

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [109.5 kB]
  • W-J-7021

    (Approval document / Penetration)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [281.3 kB]
  • W-J-8016

    (Approval document / Penetration)

    ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct

    English

    Download File [85.6 kB]
  • W-L-1289

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT pipe

    English

    Download File [104.7 kB]
  • W-L-1465

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 6" steel conduit, 4" copper or EMT w/ sheet metal sleeve

    English

    Download File [328.8 kB]
  • W-L-1056

    (Approval document / Penetration)

    Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve

    English

  • W-L-1095

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" steel, conduit or EMT pipes (one or more)

    English

  • W-J-8048

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)

    English

    Download File [327.1 kB]
  • W-J-7109

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 100" x 100" sheet metal duct (w/o damper) ((AS=0" to 2"))

    English

    Download File [336.7 kB]
  • W-J-8048

    (Approval document / Penetration)

    Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)

    English

    Download File [494.7 kB]
  • W-J-7091

    (Firestop System Details / UL Detail Drawing)

    Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 3-1/2")

    English

  • W-J-7029

    (Approval document / Penetration)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1-1/2" thickness foil scrim glass fiber duct insulation

    English

  • W-L-1058

    (Firestop System Details / UL Detail Drawing)

    Max. 16" steel, max. 4" copper, in wire mesh sleeve

    English

  • W-L-1464

    (Firestop System Details / UL Detail Drawing)

    Max. 1" single or bundled fledxible steel conduits

    English

  • W-J-7109

    (Approval document / Penetration)

    Max. 100" x 100" sheet metal duct (w/o damper) ((AS=0" to 2"))

    English

    Download File [82.6 kB]
  • W-L-1462

    (Firestop System Details / UL Detail Drawing)

    Medical gas station outlet

    English

    Download File [30.6 kB]
  • W-L-1056

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve

    English

  • W-L-0043

    (Approval document / Penetration)

    Blank opening through Gypsum wall assembly

    English

    Download File [387 kB]
  • W-L-0030

    (Approval document / Penetration)

    Max. 240 sq. in. blank opening with a max. dimension of 20" (unframed opening)

    English

  • W-J-7085

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [123.6 kB]
  • W-L-1289

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, conduit, or EMT pipe

    English

    Download File [104.7 kB]
  • W-J-7110

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-L-1110

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • W-J-7085

    (Approval document / Penetration)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [17.4 kB]
  • W-J-8048

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through concrete block wall (minimum 7-5/8" thick)

    English

    Download File [197.9 kB]
  • W-L-1290

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, copper, conduit, or EMT

    English

    Download File [94.7 kB]
  • W-L-1249

    (Firestop System Details / UL Detail Drawing)

    Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)

    English

    Download File [196.2 kB]
  • W-J-8044

    (Firestop System Details / UL Detail Drawing)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [124.3 kB]
  • W-L-1462

    (CAD/BIM Typicals / Auto CAD drawing file)

    Medical gas station outlet

    English

    Download File [294.4 kB]
  • W-J-8022

    (Approval document / Penetration)

    HVAC Line Set

    English

  • W-L-1056

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 4" copper, conduit or EMT pipe in steel sleeve

    English

  • W-J-8050

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through concrete block wall assembly (min. 5" thick)

    English

    Download File [313.2 kB]
  • W-J-7085

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [131.9 kB]
  • W-L-1304

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, conduit, or EMT

    English

    Download File [241.5 kB]
  • W-L-1170

    (Approval document / Penetration)

    Max. 6" copper, (sleeved)

    English

    Download File [77.5 kB]
  • W-J-7110

    (Firestop System Details / UL Detail Drawing)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-L-1297

    (Approval document / Penetration)

    Max. 30" steel, cast iron, max. 6" copper, steel conduit or max. 4" EMT pipe

    English

    Download File [73.1 kB]
  • W-L-1110

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" copper, conduit or max. 4" EMT in sleeve

    English

  • W-L-1440

    (Firestop System Details / UL Detail Drawing)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-L-0043

    (Firestop System Details / UL Detail Drawing)

    Blank opening through gypsum wall assembly

    English

    Download File [124.8 kB]
  • W-L-1289

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT pipe

    English

    Download File [18.8 kB]
  • W-J-7038

    (Firestop System Details / UL Detail Drawing)

    Max. 6" sheet metal duct w/o damper (Shaft Wall)

    English

  • W-L-1164

    (Approval document / Penetration)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-L-1249

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" Steel Conduit or EMT (Multiple in 30" x 12" opening)

    English

    Download File [120.2 kB]
  • W-J-8044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [318.1 kB]
  • W-L-1148

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • W-J-8050

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through concrete block wall assembly (min. 5" thick)

    English

    Download File [214.6 kB]
  • W-L-1304

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, conduit, or EMT

    English

    Download File [112.4 kB]
  • W-L-1440

    (Approval document / Penetration)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-L-1247

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [44.7 kB]
  • W-L-0013

    (Approval document / Penetration)

    Max. 4" threaded steel conduit with plastic or metal bushings

    English

  • W-L-1440

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" steel conduit or EMT with steel junction box (AS=0" to 1-1/8")

    English

  • W-L-0043

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank opening through gypsum wall assembly

    English

    Download File [367.5 kB]
  • W-L-0012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 15" blank opening

    English

    Download File [106.9 kB]
  • W-J-7038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" sheet metal duct w/o damper (Shaft Wall)

    English

  • W-L-1360

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT

    English

  • W-L-0019

    (Approval document / Penetration)

    Max. 4" steel pipe sleeve

    English

  • W-L-1148

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel or cast iron pipe or max. 4" conduit or EMT

    English

  • W-L-1214

    (Approval document / Penetration)

    Max. 1" flexible steel conduit

    English

  • W-L-0040

    (Firestop System Details / UL Detail Drawing)

    Max. 2-1/2" dia or 2" x 2" blank

    English

  • W-L-1247

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [129 kB]
  • W-J-8008

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)

    English

    Download File [272 kB]
  • W-L-1165

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-L-1095

    (Approval document / Penetration)

    Max. 1" steel, conduit or EMT pipes (one or more)

    English

  • W-L-1247

    (Approval document / Penetration)

    Max. 6" steel, cast iron, steel conduit or max. 3" copper, or max. 4" EMT pipe (one or more)

    English

    Download File [369.1 kB]
  • W-L-0012

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 15" blank opening

    English

    Download File [142.3 kB]
  • W-L-1360

    (Firestop System Details / UL Detail Drawing)

    Max. 24" steel, cast iron, max. 6" copper, steel conduit, or max. 4" EMT

    English

  • W-J-8008

    (Approval document / Penetration)

    Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)

    English

    Download File [312.9 kB]
  • W-L-1214

    (Firestop System Details / UL Detail Drawing)

    Max. 1" flexible steel conduit

    English

  • W-L-1367

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 6" steel conduit, or 4" copper, EMT

    English

    Download File [488.3 kB]
  • W-J-8034

    (Firestop System Details / UL Detail Drawing)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [176.6 kB]
  • W-L-1380

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)

    English

  • W-J-6003

    (Approval document / Penetration)

    Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")

    English

    Download File [77.9 kB]
  • W-L-0014

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 36" blank opening

    English

    Download File [307.7 kB]
  • W-J-7022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct

    English

    Download File [280.6 kB]
  • W-J-8009

    (Approval document / Penetration)

    Max. 6" steel, cast iron, copper, conduit or max. 4" EMT or max. 4" cable bundle

    English

    Download File [272.6 kB]
  • W-L-1380

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)

    English

  • W-J-8008

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrants through concrete block wall assembly (min. 7-5/8" thick)

    English

    Download File [146.7 kB]
  • W-L-1165

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-L-1058

    (Approval document / Penetration)

    Max. 16" steel, max. 4" copper, in wire mesh sleeve

    English

  • W-L-1406

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, steel conduit, max. 4" copper or EMT (UL Classified U336 or U366 Wall)

    English

  • W-L-0023

    (Firestop System Details / UL Detail Drawing)

    Max. 4" blank steel sleeve

    English

    Download File [174 kB]
  • W-J-7022

    (Approval document / Penetration)

    Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct

    English

    Download File [255.2 kB]
  • W-J-6003

    (Firestop System Details / UL Detail Drawing)

    Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")

    English

    Download File [127.5 kB]
  • W-L-1214

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" flexible steel conduit

    English

  • W-J-8016

    (CAD/BIM Typicals / Auto CAD drawing file)

    ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct

    English

    Download File [302.6 kB]
  • W-J-8034

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [271.9 kB]
  • W-L-1206

    (Approval document / Penetration)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-L-1175

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" EMT or steel conduit

    English

    Download File [114.9 kB]
  • W-L-0023

    (Approval document / Penetration)

    Max. 4" blank steel sleeve

    English

    Download File [78.6 kB]
  • W-L-0014

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 36" blank opening

    English

    Download File [121.6 kB]
  • W-L-1380

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 6" copper, 4" steel conduit or EMT (shaft wall)

    English

  • W-L-1205

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-J-7091

    (Approval document / Penetration)

    Max. 60" x 36" sheet metal duct w/o damper with max. 2" thickness foil scrim glass fiber duct insulation (w/ optional angles) (AS=1/4" to 2-1/4")

    English

  • W-J-8018

    (Firestop System Details / UL Detail Drawing)

    Cable bundle Cable Rack (Telecom) (various cables)

    English

    Download File [115.6 kB]
  • W-L-0012

    (Approval document / Penetration)

    Max. 30" x 15" blank opening

    English

    Download File [17 kB]
  • W-L-1412

    (Approval document / Penetration)

    Max. 2" steel, cast iron, steel conduit, or EMT running vertically through plane of wall on one side (AS=0" to 3/4")

    English

  • W-L-0023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" blank steel sleeve

    English

    Download File [175.2 kB]
  • W-L-0018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel pipe sleeve

    English

    Download File [301 kB]
  • W-J-6003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Fiber optic cable tray (ABS) (12" x 4") (AS=0" to 4")

    English

    Download File [226.6 kB]
  • W-L-1392

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)

    English

  • W-J-8016

    (Firestop System Details / UL Detail Drawing)

    ABS Fiber Optic Cable tray, cables (single or bundled), 2" Innerduct

    English

    Download File [242.7 kB]
  • W-L-1175

    (Firestop System Details / UL Detail Drawing)

    Max. 4" EMT or steel conduit

    English

    Download File [110.7 kB]
  • W-J-8034

    (Approval document / Penetration)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [360.3 kB]
  • W-L-1392

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron, max. 6" steel conduit or EMT (sleeved)

    English

  • W-L-1165

    (Approval document / Penetration)

    Max. 6" steel, copper, conduit or max. 4" EMT pipe in steel pipe sleeve

    English

  • W-L-0018

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel pipe sleeve

    English

    Download File [150.6 kB]
  • W-L-1205

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, max. 6" conduit, max. 4" copper, EMT or max. 2" flexible steel conduit (sleeved) (one-sided installation, includes shaft wall)

    English

  • W-J-8018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle Cable Rack (Telecom) (various cables)

    English

    Download File [280.4 kB]
  • W-L-5029

    (Approval document / Penetration)

    Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation

    English

  • W-L-8035

    (Firestop System Details / UL Detail Drawing)

    Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)

    English

    Download File [263.8 kB]
  • W-L-8013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [364.9 kB]
  • F-A-5070

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [657.8 kB]
  • W-L-3185

    (Firestop System Details / UL Detail Drawing)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [234.7 kB]
  • W-L-5261

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation

    English

  • W-L-5240

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)

    English

  • W-L-4060

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

  • W-L-5029

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation

    English

  • W-L-3382

    (Firestop System Details / UL Detail Drawing)

    Cable bundle through gypsum wall assembly (0-12" annular space)

    English

    Download File [168.1 kB]
  • W-L-7069

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)

    English

  • W-L-7143

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [104.3 kB]
  • W-L-4019

    (Approval document / Penetration)

    Spine Cable Tray

    English

    Download File [382.9 kB]
  • W-L-3071

    (Approval document / Penetration)

    Cable bundle (SER power cables)

    English

  • W-L-3296

    (Approval document / Penetration)

    Cable bundle (various cables)

    English

    Download File [31.6 kB]
  • W-L-5244

    (Approval document / Penetration)

    Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)

    English

    Download File [486.7 kB]
  • W-L-2537

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" PEX (bundled) through CP 653 Speed Sleeve

    English

  • W-L-7124

    (Firestop System Details / UL Detail Drawing)

    Max. 32"Metal Fab Grease Duct (AS varies)

    English

  • W-L-7040

    (Approval document / Penetration)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [77.9 kB]
  • W-L-7059

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1 1/2" thickness foil scrim glass fiber duct insulation

    English

  • W-L-3335

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-L-3385

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (optional 45º angle)

    English

    Download File [158 kB]
  • W-L-5027

    (Firestop System Details / UL Detail Drawing)

    Max 2" steel, copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation within a steel sleeve

    English

  • W-L-4049

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [709.1 kB]
  • W-L-5257

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [227.9 kB]
  • W-L-5274

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)

    English

  • W-L-3139

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(sleeved)

    English

  • W-L-3111

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [130.1 kB]
  • W-L-8015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrants through gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)

    English

    Download File [357.7 kB]
  • W-L-8058

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, copper, conduit or EMT, cable bundle

    English

    Download File [168.4 kB]
  • W-L-3226

    (Approval document / Penetration)

    Cable bundle (various cables)(PW Southern steel sleeve)

    English

    Download File [94.7 kB]
  • W-L-3161

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeved)(shaft wall)

    English

  • W-L-3391

    (Approval document / Penetration)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [104.5 kB]
  • W-L-7153

    (Approval document / Penetration)

    Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")

    English

  • W-L-3334

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve

    English

    Download File [110.5 kB]
  • W-L-8019

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [112.7 kB]
  • W-L-7198

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" sheet metal duct (30 Ga)

    English

  • W-L-3161

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeved)(shaft wall)

    English

  • W-L-2568

    (Approval document / Penetration)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [974.3 kB]
  • W-L-5259

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-5025

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)

    English

  • W-L-5047

    (Firestop System Details / UL Detail Drawing)

    Max. 20" steel, max. 6" copper, conduit or max. 4" EMT pipe with max. 3" Paroc insulation (Steel sleeve optional)

    English

  • W-L-3334

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-L-8086

    (Approval document / Penetration)

    Cable bundle and metallic pipe through CP 653 Speed Sleeve

    English

    Download File [86.3 kB]
  • W-L-2537

    (Firestop System Details / UL Detail Drawing)

    Max. 1" PEX (bundled) through CP 653 Speed Sleeve

    English

  • W-L-3310

    (CAD/BIM Typicals / Auto CAD drawing file)

    MC Cables (max qty 3) (membrane penetration)

    English

    Download File [191.7 kB]
  • W-L-7121

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 24" air or grease duct with 1-1/2" thick Firemaster® Fast Wrap manufactured by Thermal Ceramics

    English

  • W-L-7153

    (Firestop System Details / UL Detail Drawing)

    Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")

    English

  • W-L-4050

    (Approval document / Penetration)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [126.2 kB]
  • W-L-5126

    (Approval document / Penetration)

    Max. 10" steel pipe with max. 3" glass fiber insulation

    English

    Download File [80.5 kB]
  • W-L-2537

    (Approval document / Penetration)

    Max. 1" PEX (bundled) through CP 653 Speed Sleeve

    English

    Download File [84.3 kB]
  • W-L-8023

    (Approval document / Penetration)

    Max. 6" steel tube (16 Ga) and cables (Translogic)

    English

  • W-L-8086

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle and metallic pipe through CP 653 Speed Sleeve

    English

  • W-L-8019

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [103.9 kB]
  • W-L-7096

    (Firestop System Details / UL Detail Drawing)

    Max. 13" x 12" sheet metal duct w/o damper (no angles)

    English

  • W-L-7040

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [280 kB]
  • W-L-3384

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

  • W-L-3394

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [246.7 kB]
  • W-L-5125

    (Approval document / Penetration)

    Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation

    English

    Download File [80.3 kB]
  • W-L-4081

    (Firestop System Details / UL Detail Drawing)

    Cable tray through gypsum wall assembly

    English

    Download File [255.4 kB]
  • W-L-4038

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Tray

    English

    Download File [334.6 kB]
  • W-L-5260

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-4060

    (Approval document / Penetration)

    Cable Tray

    English

  • W-L-3112

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(sleeved)

    English

    Download File [96.7 kB]
  • W-L-3071

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (SER power cables)

    English

  • W-L-8023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel tube (16 Ga) and cables (Translogic)

    English

  • W-L-8085

    (Approval document / Penetration)

    HVAC Line Set through CP 653 Speed Sleeve

    English

    Download File [86.2 kB]
  • W-L-2567

    (Approval document / Penetration)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [289.8 kB]
  • W-L-3335

    (Approval document / Penetration)

    Blank or cables through CP 653 Speed Sleeve

    English

    Download File [86.7 kB]
  • W-L-8014

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [249.5 kB]
  • W-L-3213

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(PVC sleeve)

    English

    Download File [303.7 kB]
  • W-L-5244

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)

    English

    Download File [135.3 kB]
  • W-L-5144

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" copper with max. 2" thick glass fiber (Shaft Wall) (sleeved)

    English

  • W-L-5028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation

    English

  • W-L-7154

    (Approval document / Penetration)

    Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")

    English

  • W-L-5096

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)

    English

  • W-L-3316

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through Unique Sleeves with "gang plate"

    English

    Download File [24 kB]
  • W-L-3296

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)

    English

    Download File [230 kB]
  • W-L-7130

    (CAD/BIM Typicals / Auto CAD drawing file)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [235.3 kB]
  • W-L-7155

    (Firestop System Details / UL Detail Drawing)

    Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")

    English

    Download File [103.1 kB]
  • W-L-3139

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeved)

    English

  • W-L-3272

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeved)

    English

  • W-L-7096

    (Approval document / Penetration)

    Max. 13" x 12" sheet metal duct w/o damper (no angles)

    English

  • W-L-7042

    (Approval document / Penetration)

    Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct

    English

    Download File [76.2 kB]
  • W-L-5257

    (Approval document / Penetration)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [303.1 kB]
  • W-L-3282

    (Approval document / Penetration)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

  • W-L-2567

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [143.3 kB]
  • W-L-3079

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeve optional)

    English

    Download File [815.7 kB]
  • W-L-7068

    (Firestop System Details / UL Detail Drawing)

    Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)

    English

  • W-L-7017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" diameter sheet metal duct w/o damper

    English

  • W-L-3391

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or Cables (various) through Firestop Cable Transit

    English

    Download File [382.8 kB]
  • W-L-3396

    (Firestop System Details / UL Detail Drawing)

    Cable Bundle (various cables) (optional steel pipe sleeve)

    English

    Download File [162.5 kB]
  • W-L-3394

    (Approval document / Penetration)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [402.6 kB]
  • W-L-4050

    (Firestop System Details / UL Detail Drawing)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [382.8 kB]
  • W-L-7158

    (Approval document / Penetration)

    Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-4019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Spine Cable Tray

    English

    Download File [334.5 kB]
  • W-L-5263

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [224.8 kB]
  • W-L-6017

    (Firestop System Details / UL Detail Drawing)

    Max. 12" x 4" Fiber Optic Cable Tray (ABS)

    English

    Download File [143.9 kB]
  • W-L-5292

    (Approval document / Penetration)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • W-L-3079

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(sleeve optional)

    English

    Download File [144.1 kB]
  • W-L-3058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable (telephone cable)

    English

  • W-L-8047

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC Line Set (AS varies)

    English

  • W-L-8079

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)

    English

  • W-L-7157

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-3224

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [329.1 kB]
  • W-L-3273

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

    Download File [146.8 kB]
  • W-L-5028

    (Approval document / Penetration)

    Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. " AB/PVC insulation

    English

  • W-L-5126

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel pipe with max. 3" glass fiber insulation

    English

    Download File [117.5 kB]
  • W-L-5046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve

    English

  • W-L-5126

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel pipe with max. 3" glass fiber insulation

    English

    Download File [216.6 kB]
  • W-L-5046

    (Approval document / Penetration)

    Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve

    English

  • W-L-3307

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (UL Classified U336 or U366 Wall)

    English

  • W-L-3278

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (shaft wall) (AS=0" to 1")

    English

  • W-L-7151

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 60" x 36" sheet metal duct (w/o damper) with max. 2" thick glass fiber duct insulation (optional angles fastened through insulation) (AS=1/4" to 2-1/4")

    English

  • W-L-7157

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-8059

    (Approval document / Penetration)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [443 kB]
  • W-L-4034

    (Approval document / Penetration)

    Aluminum Cable Tray (24" x 4") (AS=0" to 5")

    English

    Download File [28.2 kB]
  • W-L-8079

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)

    English

  • W-L-3046

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (power cables)Steel sleeve

    English

  • W-L-6017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" x 4" Fiber Optic Cable Tray (ABS)

    English

    Download File [240.5 kB]
  • W-L-3393

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Firestop Retrofit Sleeve Kit

    English

    Download File [277.1 kB]
  • W-L-7188

    (Approval document / Penetration)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-L-4019

    (Firestop System Details / UL Detail Drawing)

    Spine Cable Tray

    English

    Download File [146.8 kB]
  • W-L-4048

    (Firestop System Details / UL Detail Drawing)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [163.5 kB]
  • W-L-3396

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Bundle (various cables) (optional steel pipe sleeve)

    English

    Download File [330.5 kB]
  • W-L-5292

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • W-L-7017

    (Firestop System Details / UL Detail Drawing)

    Max. 6" diameter sheet metal duct w/o damper

    English

  • W-L-3065

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")

    English

    Download File [81.3 kB]
  • W-L-3065

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")

    English

    Download File [279.8 kB]
  • W-L-3046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (power cables)Steel sleeve

    English

  • W-L-8059

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [252.5 kB]
  • W-L-3307

    (Approval document / Penetration)

    Cable bundle (various cables) (UL Classified U336 or U366 Wall)

    English

  • W-L-5240

    (Approval document / Penetration)

    Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)

    English

  • W-L-7018

    (Approval document / Penetration)

    Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)

    English

  • W-L-7124

    (Approval document / Penetration)

    Max. 32" Metal Fab Grease Duct (AS varies)

    English

  • W-L-3224

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [1 MB]
  • W-L-3185

    (Approval document / Penetration)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [80.5 kB]
  • W-L-7188

    (Firestop System Details / UL Detail Drawing)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-L-7155

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")

    English

    Download File [288.5 kB]
  • W-L-3272

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeved)

    English

    Download File [301.3 kB]
  • W-L-3278

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (shaft wall) (AS=0" to 1")

    English

  • W-L-7151

    (Approval document / Penetration)

    Max. 60" x 36" sheet metal duct (w/o damper) with max. 2" thick glass fiber duct insulation (optional angles fastened through insulation) (AS=1/4" to 2-1/4")

    English

  • W-L-5096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)

    English

  • W-L-5073

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve

    English

  • W-L-3282

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

    Download File [39.4 kB]
  • W-L-3273

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

    Download File [345.3 kB]
  • W-L-7154

    (CAD/BIM Typicals / Auto CAD drawing file)

    Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")

    English

  • W-L-6017

    (Approval document / Penetration)

    Max. 12" x 4" Fiber Optic Cable Tray (ABS)

    English

    Download File [78.4 kB]
  • W-L-3046

    (Approval document / Penetration)

    Cable bundle (power cables)Steel sleeve

    English

  • W-L-8085

    (Firestop System Details / UL Detail Drawing)

    HVAC Line Set through CP 653 Speed Sleeve

    English

  • W-L-2568

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [409.2 kB]
  • W-L-3058

    (Firestop System Details / UL Detail Drawing)

    Cable (telephone cable)

    English

  • W-L-4049

    (Approval document / Penetration)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [69.9 kB]
  • W-L-7018

    (Firestop System Details / UL Detail Drawing)

    Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)

    English

  • W-L-3395

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Cable Mangagment Devices using Firestop Gangplate

    English

    Download File [1.3 MB]
  • W-L-5143

    (Approval document / Penetration)

    Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)

    English

  • W-L-4034

    (Firestop System Details / UL Detail Drawing)

    Aluminum Cable Tray (24" x 4") (AS=0" to 5")

    English

    Download File [106.2 kB]
  • W-L-3394

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through Firestop Sleeve Kit

    English

    Download File [384.2 kB]
  • W-L-7040

    (Firestop System Details / UL Detail Drawing)

    Max. 48" x 24" sheet metal duct w/o damper

    English

    Download File [138 kB]
  • W-L-3047

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (power cables)

    English

  • W-L-8035

    (Approval document / Penetration)

    Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)

    English

    Download File [131.7 kB]
  • W-L-2567

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [250.1 kB]
  • W-L-8086

    (Firestop System Details / UL Detail Drawing)

    Cable bundle and metallic pipe through CP 653 Speed Sleeve

    English

  • W-L-8015

    (Approval document / Penetration)

    Multiple penetrants through Gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)

    English

    Download File [443.6 kB]
  • W-L-5096

    (Approval document / Penetration)

    Max. 12" steel or max. 6" copper pipe with max. 2" glass fiber insulation (steel sleeve optional) (AS varies)

    English

  • W-L-4081

    (Approval document / Penetration)

    Cable tray through Gypsum wall assembly

    English

    Download File [81.5 kB]
  • W-L-2538

    (Approval document / Penetration)

    Max. 2" ENT (one or more) through CP 653 Speed Sleeve

    English

    Download File [86.9 kB]
  • W-L-7158

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-7153

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" spiral wound duct or 12" sheet metal duct (w/o damper) with 1-1/2" glass fiber duct insulation (AS=1/4" to 1")

    English

  • W-L-3277

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeved)

    English

    Download File [134.9 kB]
  • W-L-3296

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)

    English

    Download File [166.6 kB]
  • W-L-5143

    (Firestop System Details / UL Detail Drawing)

    Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)

    English

  • W-L-5125

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation

    English

    Download File [131.7 kB]
  • W-L-3277

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(sleeved)

    English

    Download File [103.5 kB]
  • W-L-3226

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(PW Southern steel sleeve)

    English

    Download File [247.4 kB]
  • W-L-7156

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/2" to 2")

    English

  • W-L-7198

    (Firestop System Details / UL Detail Drawing)

    Max. 4" sheet metal duct (30 Ga)

    English

  • W-L-3382

    (Approval document / Penetration)

    Cable bundle through Gypsum wall assembly (0-12" annular space)

    English

    Download File [80.4 kB]
  • W-L-7155

    (Approval document / Penetration)

    Max. 100" x 100" sheet metal duct (w/o damper) (AS=0" to 2")

    English

    Download File [83.2 kB]
  • F-A-5070

    (Approval document / Penetration)

    English

    Download File [103.1 kB]
  • W-L-3273

    (Approval document / Penetration)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

    Download File [82.1 kB]
  • W-L-8081

    (Firestop System Details / UL Detail Drawing)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [166.4 kB]
  • W-L-5261

    (Approval document / Penetration)

    Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation

    English

  • W-L-8058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, copper, conduit or EMT, cable bundle

    English

    Download File [223.7 kB]
  • W-L-3047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (power cables)

    English

  • W-L-3071

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (SER power cables)

    English

  • W-L-6019

    (Firestop System Details / UL Detail Drawing)

    Max. 11-1/4" x 4-1/4" Electrical Busway

    English

  • W-L-7069

    (Approval document / Penetration)

    Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)

    English

  • W-L-5274

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)

    English

  • W-L-4049

    (Firestop System Details / UL Detail Drawing)

    Multiple Cable Racks (optional) in max. 24" x 36" opening

    English

    Download File [373.9 kB]
  • W-L-4011

    (Firestop System Details / UL Detail Drawing)

    Aluminum Cable Tray (24" x 6") (AS=0" to 4")

    English

    Download File [100.2 kB]
  • W-L-3392

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cables (various) through Firestop Cable Transit

    English

    Download File [385.7 kB]
  • W-L-6019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 11-1/4" x 4-1/4" Electrical Busway

    English

  • W-L-7059

    (Approval document / Penetration)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1 ›" thickness foil scrim glass fiber duct insulation

    English

  • W-L-7059

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" sheet metal duct w/o damper with max. 1 1/2" thickness foil scrim glass fiber duct insulation

    English

  • W-L-2568

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) in flexible nylon fiber optic cable routing system (sleeved) (AS=0" to 1" outside sleeve) (AS=0" to 3" inside sleeve)

    English

    Download File [169.6 kB]
  • W-L-8081

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [290 kB]
  • W-L-5259

    (Approval document / Penetration)

    Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-3278

    (Approval document / Penetration)

    Cable bundle (various cables) (shaft wall) (AS=0" to 1")

    English

  • W-L-3111

    (Approval document / Penetration)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [308.8 kB]
  • W-L-7157

    (Approval document / Penetration)

    Max. 24" x 24" steel greas duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-5274

    (Approval document / Penetration)

    Max. 2" steel, cast iron, or copper with 1-1/2" glass fiber pipe insulation (AS=0", cont. point of contact)

    English

  • W-L-3385

    (Approval document / Penetration)

    Cable bundle (various cables) (optional 45┬║ angle)

    English

    Download File [75.2 kB]
  • W-L-7156

    (Firestop System Details / UL Detail Drawing)

    Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/4" to 3-1/2")

    English

  • W-L-7143

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [148.7 kB]
  • W-L-3282

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Unique Firestop Sleeve)

    English

    Download File [359.3 kB]
  • W-L-3310

    (Firestop System Details / UL Detail Drawing)

    MC Cables (max qty 3) (membrane penetration)

    English

    Download File [100.8 kB]
  • W-L-5125

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel, cast iron or max. 4" copper pipe with max. 3" glass fiber insulation

    English

    Download File [274.2 kB]
  • W-L-5029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron or max. 6" copper 1", 1-1/2", or 2" glass fiber or max. 2" calcium silicate insulation

    English

  • W-L-5143

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" copper with max. 3/4" thick AB/PVC (Shaft Wall) (sleeved)

    English

  • W-L-5240

    (Firestop System Details / UL Detail Drawing)

    Max. 8" steel, cast iron, 4" copper with 1" or 1-1/2" thick glass fiber pipe insulation (shaft wall)

    English

  • W-L-3272

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(sleeved)

    English

    Download File [156.3 kB]
  • W-L-8079

    (Approval document / Penetration)

    Insulated or non-insulated metallic, non metallic pipes, and cable bundle (AS varies) (unframed opening)

    English

  • W-L-3220

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(Unique Firestop Sleeve)

    English

    Download File [207.9 kB]
  • W-L-7158

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 12" steel air or grease duct w/ 1-1/2" duct wrap manufactured by Unifrax

    English

  • W-L-8013

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [256.7 kB]
  • W-L-5027

    (Approval document / Penetration)

    Max 2" steel, copper, conduit or EMT pipe with max. " AB/PVC insulation within a steel sleeve

    English

  • W-L-8013

    (Approval document / Penetration)

    Insulated or non-insulated steel, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [94.3 kB]
  • W-L-8035

    (CAD/BIM Typicals / Auto CAD drawing file)

    Fiber Optic cable tray (ABS), Cable Bundle, Max. 2" Fiber Optic Raceway (PVC) (AS varies)

    English

    Download File [340.9 kB]
  • W-L-3065

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional) (AS=0" to 1")

    English

    Download File [116.9 kB]
  • W-L-8058

    (Approval document / Penetration)

    Insulated or non-insulated steel, copper, conduit or EMT, cable bundle

    English

    Download File [35.1 kB]
  • W-L-3111

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [123.6 kB]
  • W-L-5261

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, cast iron or 6" copper with 2" foam glass insulation

    English

  • W-L-4034

    (CAD/BIM Typicals / Auto CAD drawing file)

    Aluminum Cable Tray (24" x 4") (AS=0" to 5")

    English

    Download File [209.6 kB]
  • W-L-4060

    (Firestop System Details / UL Detail Drawing)

    Cable Tray

    English

  • W-L-5223

    (Approval document / Penetration)

    Max. 12" steel or 6" copper with Nom. 1-1/2" or 3" thick Foam Glass pipe insulation

    English

  • W-L-3385

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (optional 45º angle)

    English

    Download File [108.3 kB]
  • W-L-7018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" diameter sheet metal duct with max. 1" thick glass fiber insulation (w/o damper)

    English

  • W-L-7069

    (Firestop System Details / UL Detail Drawing)

    Max. 7" x 7" sheet metal duct w/o damper (No angles) (Shaft Wall ) (sleeved)

    English

  • W-L-3392

    (Approval document / Penetration)

    Cables (various) through Firestop Cable Transit

    English

    Download File [1.4 MB]
  • W-L-4038

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [81.6 kB]
  • W-L-8085

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC Line Set through CP 653 Speed Sleeve

    English

  • W-L-3393

    (Approval document / Penetration)

    Blank or cables through Firestop Retrofit Sleeve Kit

    English

    Download File [146.9 kB]
  • W-L-7198

    (Approval document / Penetration)

    Max. 4" sheet metal duct (30 Ga)

    English

  • W-L-3396

    (Approval document / Penetration)

    Cable Bundle (various cables) (optional steel pipe sleeve)

    English

    Download File [468.1 kB]
  • W-L-3058

    (Approval document / Penetration)

    Cable (telephone cable)

    English

  • W-L-3310

    (Approval document / Penetration)

    MC Cables (max qty 3) (membrane penetration)

    English

    Download File [238.7 kB]
  • W-L-7154

    (Firestop System Details / UL Detail Drawing)

    Mechanical Support Member (steel strut, steel angle, steel channel) (shaft wall) (membrane penetration) (AS=0" to 7/8")

    English

  • W-L-7017

    (Approval document / Penetration)

    Max. 6" diameter sheet metal duct w/o damper

    English

    Download File [263.5 kB]
  • W-L-7124

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 32"Metal Fab Grease Duct (AS varies)

    English

  • W-L-3307

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (UL Classified U336 or U366 Wall)

    English

  • W-L-2538

    (Firestop System Details / UL Detail Drawing)

    Max. 2" ENT (one or more) through CP 653 Speed Sleeve

    English

  • W-L-5073

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve

    English

  • W-L-5027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max 2" steel, copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation within a steel sleeve

    English

  • W-L-5223

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel or 6" copper with Nom. 1-1/2" or 3" thick Foam Glass pipe insulation

    English

  • W-L-7130

    (Approval document / Penetration)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [338.6 kB]
  • W-L-5257

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation

    English

    Download File [140.7 kB]
  • W-L-3224

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (sleeve optional)

    English

    Download File [145.6 kB]
  • W-L-3185

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle Cable Rack (Telecom) (various Cables)

    English

    Download File [255.6 kB]
  • W-L-7188

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. W14 x 90 Steel I-beam service support (AS=1/2" to 3")

    English

  • W-L-8015

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrants through gypsum wall assembly (combination of max 12" steel, max 6" copper, max 6" steel conduit, max 4" EMT)

    English

    Download File [167.6 kB]
  • W-L-3220

    (Approval document / Penetration)

    Cable bundle (various cables)(Unique Firestop Sleeve)

    English

    Download File [644 kB]
  • W-L-3213

    (Approval document / Penetration)

    Cable bundle (various cables)(PVC sleeve)

    English

    Download File [83.3 kB]
  • W-L-7143

    (Approval document / Penetration)

    Max. 24" x 24" sheet metal duct w/o damper (no angles)

    English

    Download File [18.3 kB]
  • W-L-6019

    (Approval document / Penetration)

    Max. 11-1/4" x 4-1/4" Electrical Busway

    English

  • W-L-3316

    (Approval document / Penetration)

    Cable bundle (various cables) through Unique Sleeves with "gang plate"

    English

    Download File [21.4 kB]
  • W-L-8059

    (Firestop System Details / UL Detail Drawing)

    Multiple steel pipe, steel conduit, EMT and/or cable bundle

    English

    Download File [177.9 kB]
  • W-L-8019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, flexible metal conduit or cables (single or bundled)

    English

    Download File [528.2 kB]
  • W-L-3079

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeve optional)

    English

    Download File [314.8 kB]
  • F-A-5070

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [109.2 kB]
  • W-L-3047

    (Approval document / Penetration)

    Cable bundle (power cables)

    English

  • W-L-5292

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or cast iron pipe with max. 4" calcium silicate pipe insulation

    English

  • W-L-5259

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron or copper with 1-1/2" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-4048

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [261.9 kB]
  • W-L-5025

    (Firestop System Details / UL Detail Drawing)

    Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)

    English

  • W-L-3393

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through Firestop Retrofit Sleeve Kit

    English

    Download File [40.3 kB]
  • W-L-3382

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle through gypsum wall assembly (0-12" annular space)

    English

    Download File [293.4 kB]
  • W-L-7042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 20" spiral wound duct w/o damper, or 12" sheet metal duct

    English

    Download File [230.2 kB]
  • W-L-7121

    (Firestop System Details / UL Detail Drawing)

    Max. 30" x 24" air or grease duct with 1-1/2" thick Firemaster® Fast Wrap manufactured by Thermal Ceramics

    English

  • W-L-2538

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" ENT (one or more) through CP 653 Speed Sleeve

    English

  • W-L-4048

    (Approval document / Penetration)

    Cable Rack in max. 24" x 36" opening

    English

    Download File [413 kB]
  • W-L-5144

    (Approval document / Penetration)

    Max. 1" copper with max. 2" thick glass fiber (Shaft Wall) (sleeved)

    English

  • W-L-8047

    (Approval document / Penetration)

    HVAC Line Set (AS varies)

    English

  • W-L-8014

    (Approval document / Penetration)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [644.4 kB]
  • W-L-7096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 13" x 12" sheet metal duct w/o damper (no angles)

    English

  • W-L-3316

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through Unique Sleeves with "gang plate"

    English

    Download File [168.1 kB]
  • W-L-3335

    (Firestop System Details / UL Detail Drawing)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-L-5073

    (Approval document / Penetration)

    Max. 6" steel, copper, conduit or EMT pipe with max. 1-1/2" glass fiber insulation in a sleeve

    English

  • W-L-5046

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel or max. 6" copper pipe with max. 3" FOAMGLAS insulation within a steel sleeve

    English

  • W-L-4081

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable tray through gypsum wall assembly

    English

    Download File [252.9 kB]
  • W-L-5260

    (Firestop System Details / UL Detail Drawing)

    Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-5025

    (Approval document / Penetration)

    Max. 10" steel pipe with max. 2" glass fiber insulation (Steel sleeve optional)

    English

  • W-L-3213

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables)(PVC sleeve)

    English

    Download File [139 kB]
  • W-L-3139

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeved)

    English

  • W-L-8023

    (Firestop System Details / UL Detail Drawing)

    Max. 6" steel tube (16 Ga) and cables (Translogic)

    English

  • W-L-3395

    (Approval document / Penetration)

    Blank or cables through Cable Mangagment Devices using Firestop Gangplate

    English

    Download File [173.7 kB]
  • W-L-8081

    (Approval document / Penetration)

    Multiple HVAC Line Sete (max qty 3) bundled together (AS=0" to 1-1/2")

    English

    Download File [459 kB]
  • W-L-3384

    (Approval document / Penetration)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

    Download File [120.6 kB]
  • W-L-8047

    (Firestop System Details / UL Detail Drawing)

    HVAC Line Set (AS varies)

    English

  • W-L-8014

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated or non-insulated steel, cast iron, copper, conduit or EMT pipes, plastic pipe, cable tray or cables (single or bundled)

    English

    Download File [316.9 kB]
  • W-L-3112

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables)(sleeved)

    English

    Download File [217.5 kB]
  • W-L-5263

    (Approval document / Penetration)

    Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [342.9 kB]
  • W-L-5263

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, cast iron, max 2" copper with 3/4" AB/PVC pipe insulation (AS=0" to 7/8")

    English

    Download File [136.4 kB]
  • W-L-5244

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel, cast iron, or copper w/ max. 2" glass fiber pipe insulation (shaft wall)

    English

    Download File [233.5 kB]
  • W-L-4050

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple Cable Racks (optional) in max. 36" x 48" opening

    English

    Download File [799.3 kB]
  • W-L-7156

    (Approval document / Penetration)

    Max. 100" x 100" sheet metal duct (w/o damper) with 1-1/2" or 2" thick glass fiber duct insulation (insulation split for angles) (AS=1/2" to 2")

    English

  • W-L-5028

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel, max. 2" copper, conduit or EMT pipe with max. 3/4" AB/PVC insulation

    English

  • W-L-3384

    (Firestop System Details / UL Detail Drawing)

    Cable Bundle (various cables) through "ganged" Speed Sleeves

    English

  • W-L-3334

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables through CP 653 Speed Sleeve

    English

  • W-L-7068

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)

    English

  • W-L-7130

    (Firestop System Details / UL Detail Drawing)

    Mechanical support mechanisms (strut, steel cable, steel rod, steel angle)

    English

    Download File [126.3 kB]
  • W-L-3112

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeved)

    English

    Download File [754 kB]
  • W-L-3277

    (Approval document / Penetration)

    Cable bundle (various cables)(sleeved)

    English

  • W-L-5260

    (Approval document / Penetration)

    Max. 2" steel, cast iron or copper with 3/4" glass fiber (UL Classified U336 or U366 Wall)

    English

  • W-L-7068

    (Approval document / Penetration)

    Max. 6" sheet metal duct w/o damper (Shaft Wall) (sleeved)

    English

  • TP-CS-SL SA

    (Firestop System Details / UL Detail Drawing)

    Through penetration for non fire-rated smoke partitions

    English

    Download File [272.2 kB]
  • F-C-2416

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • C-AJ-2684

    (Firestop System Details / UL Detail Drawing)

    English

  • F-C-1168

    (Approval document / Penetration)

    Max. 3/4" steel, iron, conduit, or EMT pipe; Max. 1/2" copper tubing or copper pipe; AS = Min. 0"

    English

    Download File [88.9 kB]
  • F-B-2053

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [26.1 kB]
  • C-AJ-0141

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24” blank opening (Mineral Wool & Silicone Sealant)

    English

    Download File [252.4 kB]
  • HI/PF 120-04

    (Approval document / Penetration)

    English

  • W-L-5011

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-8098

    (Approval document / Penetration)

    Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)

    English

    Download File [423.6 kB]
  • F-A-1136

    (Approval document / Penetration)

    English

    Download File [343.6 kB]
  • F-C-7058

    (Approval document / Penetration)

    English

  • W-L-0005

    (Approval document / Penetration)

    English

  • W-L-3234

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through gypsum board wall (Max. 34% fill) in unique threaded sleeve or threaded split sleeve

    English

    Download File [147.3 kB]
  • C-AJ-8248

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [586.5 kB]
  • W-J-2027

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [101.9 kB]
  • F-A-5047

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [22.5 kB]
  • W-J-2027

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [192.1 kB]
  • W-J-0024

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [134.9 kB]
  • W-L-8093

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through gypsum wall assembly (various cable and pipe sizes)

    English

    Download File [312 kB]
  • W-L-3413

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [160.1 kB]
  • C-AJ-7153

    (Approval document / Penetration)

    English

    Download File [83.9 kB]
  • F-C-2045

    (Approval document / Penetration)

    English

  • W-J-2032

    (Firestop System Details / UL Detail Drawing)

    English

  • W-L-5011

    (Firestop System Details / UL Detail Drawing)

    English

  • C-AJ-2080

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [297.2 kB]
  • C-AJ-1664

    (Approval document / Penetration)

    English

    Download File [300.3 kB]
  • W-J-3215

    (Approval document / Penetration)

    Cable bundle; VF = 0 - 100%; AS = Min. 0"

    English

    Download File [91.3 kB]
  • F-C-2035

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [299.4 kB]
  • C-AJ-1661

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [283.3 kB]
  • C-AJ-1661

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [115.9 kB]
  • C-AJ-7152

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [295.7 kB]
  • F-C-2416

    (Firestop System Details / UL Detail Drawing)

    English

  • F-C-1168

    (Firestop System Details / UL Detail Drawing)

    Max. 3/4" steel, iron, conduit, or EMT pipe; Max. 1/2" copper tubing or copper pipe; AS = Min. 0"

    English

    Download File [93.5 kB]
  • C-AJ-8014

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [405.3 kB]
  • F-C-2416

    (Approval document / Penetration)

    English

  • W-L-2062

    (Approval document / Penetration)

    English

  • C-AJ-1612

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [95.5 kB]
  • W-J-7123

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [121.1 kB]
  • W-L-3413

    (Approval document / Penetration)

    English

    Download File [79.6 kB]
  • HI/PF 120-05

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-A-2317

    (Approval document / Penetration)

    English

    Download File [119.7 kB]
  • C-AJ-2677

    (Approval document / Penetration)

    English

    Download File [88.5 kB]
  • C-AJ-7154

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [174.1 kB]
  • C-BJ-1069

    (Approval document / Penetration)

    English

    Download File [87.1 kB]
  • C-AJ-6048

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [155.2 kB]
  • W-L-8098

    (Firestop System Details / UL Detail Drawing)

    Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)

    English

    Download File [153.4 kB]
  • F-A-3073

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [698.8 kB]
  • C-AJ-0142

    (Firestop System Details / UL Detail Drawing)

    Max. 6” blank opening (Mineral Wool & Silicone Sealant)

    English

    Download File [97.4 kB]
  • F-A-2310

    (Approval document / Penetration)

    English

    Download File [95.8 kB]
  • W-L-2061

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-3415

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle, Visual Fill = 0 - 100%; AS = Min. 0"

    English

    Download File [370.8 kB]
  • W-L-7214

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [252.8 kB]
  • C-AJ-7150

    (Approval document / Penetration)

    English

    Download File [153.1 kB]
  • W-J-2030

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-2565

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [167.6 kB]
  • W-J-2029

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [264.9 kB]
  • C-AJ-4106

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [125.9 kB]
  • C-AJ-7153

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [252.9 kB]
  • W-L-3414

    (Approval document / Penetration)

    Cable bundle; VF = 0 - 100%; AS = Min. 0"

    English

    Download File [78.2 kB]
  • F-C-5088

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel pipe, iron pipe, copper tubing, copper pipe

    English

    Download File [76.2 kB]
  • C-AJ-2079

    (Approval document / Penetration)

    English

  • F-C-5088

    (Approval document / Penetration)

    Max. 4" steel pipe, iron pipe, copper tubing, or copper pipe

    English

    Download File [147.1 kB]
  • C-AJ-2677

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [296.7 kB]
  • C-AJ-6048

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [124 kB]
  • F-C-1168

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 3/4" steel, iron, conduit or EMT; Max. 1/2" copper tubing or pipe; AS = Min. 0"

    English

    Download File [410.7 kB]
  • W-L-2052

    (Approval document / Penetration)

    English

    Download File [783.3 kB]
  • W-L-3414

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle, Visual Fill = 0 - 100%; AS = Min. 0"

    English

    Download File [378.1 kB]
  • C-AJ-8014

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [178.8 kB]
  • F-C-7059

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • HI/PF 120-03

    (Approval document / Penetration)

    English

  • W-K-3002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable Bundle (Max. 100% visual fill)

    English

    Download File [608.5 kB]
  • F-B-2011

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [109.8 kB]
  • C-AJ-7149

    (Approval document / Penetration)

    English

    Download File [207.5 kB]
  • W-L-2062

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-C-7059

    (Approval document / Penetration)

    English

  • F-B-1032

    (Approval document / Penetration)

    Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)

    English

    Download File [74.7 kB]
  • C-AJ-4106

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [276.6 kB]
  • W-L-8094

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through gypsum wall assembly (various cable and cable bundle sizes)

    English

    Download File [233.1 kB]
  • W-K-3002

    (Firestop System Details / UL Detail Drawing)

    Cable Bundle (Max. 100% visual fill)

    English

    Download File [179.7 kB]
  • C-AJ-7150

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [40.3 kB]
  • C-AJ-1630

    (Approval document / Penetration)

    English

    Download File [381.1 kB]
  • F-C-2035

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [138.4 kB]
  • W-J-7124

    (Firestop System Details / UL Detail Drawing)

    English

  • HI/PF 120-05

    (Approval document / Penetration)

    English

  • W-L-2565

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [326.3 kB]
  • F-A-5069

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [762.7 kB]
  • W-L-2061

    (Approval document / Penetration)

    English

  • W-J-2029

    (Approval document / Penetration)

    English

    Download File [310.9 kB]
  • C-AJ-7149

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [255.5 kB]
  • C-AJ-2684

    (Approval document / Penetration)

    English

  • W-J-2029

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [147.8 kB]
  • F-B-1032

    (Firestop System Details / UL Detail Drawing)

    Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)

    English

    Download File [106.9 kB]
  • F-A-1136

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [264.1 kB]
  • C-AJ-1662

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [99.1 kB]
  • C-AJ-1661

    (Approval document / Penetration)

    English

    Download File [73.2 kB]
  • F-A-3073

    (Approval document / Penetration)

    English

    Download File [97.3 kB]
  • W-L-3233

    (Approval document / Penetration)

    Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded sleeve

    English

    Download File [76.6 kB]
  • HI/PF 60-01

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-J-2031

    (Firestop System Details / UL Detail Drawing)

    English

  • C-AJ-2079

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • C-AJ-7152

    (Approval document / Penetration)

    English

    Download File [152.3 kB]
  • W-L-7213

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [306.8 kB]
  • F-B-2053

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [231.3 kB]
  • C-BJ-1069

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [155.9 kB]
  • C-AJ-6048

    (Approval document / Penetration)

    English

    Download File [78.6 kB]
  • C-AJ-7151

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [41 kB]
  • W-L-7214

    (Approval document / Penetration)

    English

    Download File [75.1 kB]
  • C-AJ-8014

    (Approval document / Penetration)

    English

    Download File [806.3 kB]
  • W-L-3233

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded sleeve

    English

    Download File [147.2 kB]
  • TP-CS-SL SA

    (CAD/BIM Typicals / Auto CAD drawing file)

    Through penetration for non fire-rated smoke partitions

    English

    Download File [1.5 MB]
  • F-A-5047

    (Approval document)

    English

    Download File [78 kB]
  • C-AJ-0142

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6” blank opening (Mineral Wool & Silicone Sealant)

    English

    Download File [243.8 kB]
  • HI/PF 120-04

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-A-2316

    (Approval document / Penetration)

    English

    Download File [94.6 kB]
  • F-B-2010

    (Approval document)

    English

    Download File [225.7 kB]
  • C-AJ-2678

    (Firestop System Details / UL Detail Drawing)

    English

  • W-J-3215

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle, Visual fill = 0 - 100%; AS = Min. 0"

    English

    Download File [363.4 kB]
  • F-A-5047

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [281.2 kB]
  • F-C-2045

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-J-2031

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-2060

    (Firestop System Details / UL Detail Drawing)

    English

  • F-C-3110

    (Firestop System Details / UL Detail Drawing)

    Cable bundle, VF = 0 - 100%; AS = Min. 0"

    English

    Download File [99.2 kB]
  • C-AJ-2674

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [307.1 kB]
  • F-B-2051

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [46.9 kB]
  • W-J-7123

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [282.1 kB]
  • C-AJ-8218

    (Approval document)

    English

    Download File [419.6 kB]
  • F-B-2008

    (Approval document)

    English

    Download File [448.2 kB]
  • F-A-5069

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [107.8 kB]
  • W-L-0005

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-A-2219

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [261.6 kB]
  • F-A-2219

    (Approval document)

    English

    Download File [354.4 kB]
  • C-AJ-2080

    (Approval document)

    English

    Download File [83.1 kB]
  • W-J-7123

    (Approval document)

    English

    Download File [331.5 kB]
  • W-L-2057

    (Approval document)

    English

    Download File [581.7 kB]
  • W-L-2578

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [284.4 kB]
  • HI/PF 120-02

    (Approval document)

    English

  • F-B-2010

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [95.5 kB]
  • F-C-7058

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-5011

    (Approval document)

    English

  • C-AJ-1662

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [269.5 kB]
  • F-B-1032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nom. 1-1/2" or 2" steel or iron pipe, tub box (Min. 6" concrete)

    English

    Download File [285.7 kB]
  • F-B-2049

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [395.2 kB]
  • W-L-2578

    (Firestop System Details / UL Detail Drawing)

    English

  • W-J-2032

    (Approval document)

    English

  • C-AJ-2678

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [367.1 kB]
  • W-L-2060

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-J-2027

    (Approval document)

    English

    Download File [253.2 kB]
  • W-L-3230

    (CAD/BIM Typicals / Auto CAD drawing file)

    Angled cable membrane penetration through gypsum board wall (Max. 0.4 sq. in.)

    English

    Download File [104.7 kB]
  • W-J-0024

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [93.8 kB]
  • W-L-2603

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1-1/4" PP pipe (c)

    English

    Download File [348.2 kB]
  • W-L-0005

    (Firestop System Details / UL Detail Drawing)

    English

  • C-AJ-0142

    (Approval document / Penetration)

    Max. 6” blank opening (Mineral Wool & Silicone Sealant)

    English

    Download File [192.4 kB]
  • C-AJ-8248

    (Approval document)

    English

    Download File [128.6 kB]
  • W-L-8093

    (Firestop System Details / UL Detail Drawing)

    Multiple penetrating items through gypsum wall assembly (various cable and pipe sizes)

    English

    Download File [269.4 kB]
  • C-AJ-8248

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [276.6 kB]
  • C-AJ-7149

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [27.9 kB]
  • W-L-3415

    (Approval document / Penetration)

    Cable bundle; VF = 0 - 100%; AS = Min. 0"

    English

    Download File [90.6 kB]
  • F-B-2008

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [164.8 kB]
  • C-AJ-7151

    (Approval document)

    English

    Download File [153.7 kB]
  • F-C-3110

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle, Visual fill 0-100%; AS = Min. 0"

    English

    Download File [374.7 kB]
  • F-C-2035

    (Approval document)

    English

    Download File [417.4 kB]
  • HI/PF 120-01

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-7214

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [23.2 kB]
  • W-J-2030

    (Firestop System Details / UL Detail Drawing)

    English

  • W-L-2603

    (Approval document / Penetration)

    Max. 1-1/4" PP pipe (c)

    English

    Download File [92.7 kB]
  • C-AJ-1663

    (Approval document)

    English

    Download File [72.2 kB]
  • F-B-2011

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [264 kB]
  • C-AJ-1664

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [130.7 kB]
  • C-AJ-7154

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [351.9 kB]
  • F-B-1033

    (Approval document / Penetration)

    Nom. 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)

    English

    Download File [78.2 kB]
  • C-AJ-1612

    (Approval document)

    English

    Download File [350.5 kB]
  • C-AJ-7151

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [300.7 kB]
  • F-A-2317

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [1.1 MB]
  • C-AJ-1612

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [326.7 kB]
  • F-C-7057

    (Approval document)

    English

  • C-AJ-2079

    (Firestop System Details / UL Detail Drawing)

    English

  • W-L-7213

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [22.6 kB]
  • HI/PF 120-03

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-B-2011

    (Approval document)

    English

    Download File [252.4 kB]
  • C-AJ-2674

    (Approval document)

    English

    Download File [424 kB]
  • C-AJ-1664

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [283 kB]
  • C-AJ-1663

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [267.7 kB]
  • F-A-2316

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [457.7 kB]
  • C-AJ-7153

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [39.5 kB]
  • C-AJ-2678

    (Approval document)

    English

    Download File [153.4 kB]
  • W-J-2032

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-8094

    (Approval document / Penetration)

    Multiple penetrating items through Gypsum wall assembly (various cable and cable bundle sizes)

    English

    Download File [82.9 kB]
  • W-L-2057

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [132.1 kB]
  • W-L-7213

    (Approval document)

    English

    Download File [77.5 kB]
  • W-L-3413

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [239.4 kB]
  • C-AJ-5098

    (Approval document / Penetration)

    Max. 6" steel or copper pipe with max. 3" thick glass fiber insulation (Steel sleeve optional) (AS=1/2")

    English

    Download File [77.4 kB]
  • W-L-3230

    (Approval document / Penetration)

    Angled cable membrane penetration through gypsum board wall (Max. 0.4 sq. in.)

    English

    Download File [77.8 kB]
  • W-L-2061

    (Firestop System Details / UL Detail Drawing)

    English

  • W-L-2052

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [222 kB]
  • C-AJ-7150

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [306.2 kB]
  • W-J-2030

    (Approval document)

    English

  • C-AJ-8218

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [307.5 kB]
  • C-AJ-1663

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [111.9 kB]
  • W-L-2060

    (Approval document)

    English

  • C-AJ-1662

    (Approval document)

    English

    Download File [72.5 kB]
  • F-A-2219

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [119.9 kB]
  • W-L-2062

    (Firestop System Details / UL Detail Drawing)

    English

  • F-A-2156

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [173.7 kB]
  • W-L-3232

    (Approval document / Penetration)

    Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded split sleeve

    English

    Download File [76.7 kB]
  • HI/PF 60-01

    (Approval document)

    English

  • HI/PF 120-01

    (Approval document / Penetration)

    English

  • F-C-7057

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-K-3002

    (Approval document / Penetration)

    Cable Bundle (Max. 100% visual fill)

    English

    Download File [93.1 kB]
  • F-A-2317

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [141 kB]
  • W-L-8093

    (Approval document / Penetration)

    Multiple penetrating items through Gypsum wall assembly (various cable and pipe sizes)

    English

    Download File [627.1 kB]
  • W-L-2565

    (Approval document)

    English

    Download File [909.8 kB]
  • C-AJ-8249

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [157.8 kB]
  • C-AJ-8249

    (Approval document)

    English

    Download File [101.2 kB]
  • F-A-1136

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [22.5 kB]
  • F-B-1033

    (Firestop System Details / UL Detail Drawing)

    Nom. 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)

    English

    Download File [132.1 kB]
  • C-AJ-0141

    (Approval document / Penetration)

    Max. 24” blank opening (Mineral Wool & Silicone Sealant)

    English

    Download File [169.3 kB]
  • W-J-2031

    (Approval document)

    English

  • F-C-2045

    (Firestop System Details / UL Detail Drawing)

    English

  • W-L-2578

    (Approval document)

    English

    Download File [697.3 kB]
  • C-BJ-1069

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [201.6 kB]
  • W-L-2057

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [194.3 kB]
  • W-L-3232

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through gypsum board wall (Max. 48% fill) in unique threaded split sleeve

    English

    Download File [147.8 kB]
  • F-C-3110

    (Approval document / Penetration)

    Cable bundle; VF = 0 - 100%; AS = Min. 0"

    English

    Download File [79.4 kB]
  • W-L-8098

    (CAD/BIM Typicals / Auto CAD drawing file)

    Metal pipes, insulated pipes, cable bundles through Gypsum Shaft Wall (No max annular space)

    English

    Download File [286.2 kB]
  • F-B-2049

    (Approval document)

    English

    Download File [475.8 kB]
  • C-AJ-5098

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" steel or copper pipe with max. 3" thick glass fiber insulation (Steel sleeve optional) (AS=1/2")

    English

    Download File [134 kB]
  • W-L-2052

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [174.6 kB]
  • F-B-2008

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [302.7 kB]
  • C-AJ-2684

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • F-A-2310

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [679.5 kB]
  • F-B-2053

    (Approval document)

    English

    Download File [80.5 kB]
  • W-L-3234

    (Approval document / Penetration)

    Cable bundle (various cables) through gypsum board wall (Max. 34% fill) in unique threaded sleeve or threaded split sleeve

    English

    Download File [77.9 kB]
  • HI/PF 120-02

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • C-AJ-1630

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [378.1 kB]
  • F-B-1033

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal 3" or 4" steel or iron pipe, toilet flange / water closet (Min. 6" concrete)

    English

    Download File [156.4 kB]
  • C-AJ-2080

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [100.4 kB]
  • C-AJ-2674

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [179 kB]
  • F-C-5088

    (Firestop System Details / UL Detail Drawing)

    Max. 4" steel pipe, iron pipe, copper tubing, copper pipe

    English

    Download File [103.5 kB]
  • W-J-7124

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • C-AJ-7154

    (Approval document / Penetration)

    English

    Download File [88.1 kB]
  • W-L-8094

    (CAD/BIM Typicals / Auto CAD drawing file)

    Multiple penetrating items through gypsum wall assembly (various cable and cable bundle sizes)

    English

    Download File [368.4 kB]
  • F-B-2010

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [215.2 kB]
  • W-J-7124

    (Approval document)

    English

  • W-L-2649

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 6" Cosmoplast PP-R pipe or HDPE, or Max. 4" Coprax or Aquatherm Greenpipe PP-R pipe (AS varies) (Sheet Metal Sleeve, CP 648E wrap insert & FS-ONE MAX)

    English

    Download File [391.6 kB]
  • W-L-2676

    (Firestop System Details / UL Detail Drawing)

    Max. 2" ENT (AS=0" to 1/2")

    English

    Download File [94.2 kB]
  • W-L-8110

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set through Firestop Sleeve Kit

    English

    Download File [268.2 kB]
  • (DWG) W-J-5194

    (CAD/BIM Typicals / Auto CAD drawing file)

    One or more Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation (Max Qty. = 4) (Sealant, wrap strip & retaining collar)

    English

    Download File [282.5 kB]
  • ASSET_DOC_LOC_8844106

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation

    English

    Download File [234.8 kB]
  • C-BJ-3039

    (Approval document / Penetration)

    English

    Download File [80 kB]
  • W-L-7277

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-8110

    (Firestop System Details / UL Detail Drawing)

    HVAC line set through Firestop Sleeve Kit

    English

    Download File [95.2 kB]
  • F-A-5062

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" steel or copper pipe with nom. 1-1/2" thickness cellular glass (foamglass) insulation (4-1/2" concrete) (CP 680-P Cast-In Device)

    English

    Download File [1.3 MB]
  • W-J-2332

    (Firestop System Details / UL Detail Drawing)

    Max. 2" electrical non-metallic tubing (ENT)

    English

    Download File [92.5 kB]
  • W-J-8055

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [475.9 kB]
  • C-AJ-7192

    (Firestop System Details / UL Detail Drawing)

    Max. 30” x 30” steel sheet metal air duct (w/o steel angles) (Min. 24 ga. for 2 hour, Min. 22 ga for 3 hour) (AS=1/2” to 1-1/2”)

    English

    Download File [104.3 kB]
  • F-B-1035

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, cast iron, copper, steel conduit, or EMT (through Concrete Floor or Hollow-Core Floor) inside Optional Gypsum Chase Wall

    English

    Download File [318.9 kB]
  • W-L-2744

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [112 kB]
  • W-L-5345

    (Approval document / Penetration)

    Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation

    English

    Download File [326.2 kB]
  • W-J-1299

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [97.6 kB]
  • W-L-4087

    (Approval document / Penetration)

    English

    Download File [355 kB]
  • F-A-8047

    (Approval document / Penetration)

    Single HVAC Line Set through CFS-DID Firestop Drop-In Device 3" MD or C

    English

    Download File [84.5 kB]
  • W-L-5345

    (Firestop System Details / UL Detail Drawing)

    Max. 7/8" Streamline ACR-Type L Copper Tubing with Nom. 1/2" Polyethylene Insulation

    English

    Download File [105.3 kB]
  • C-BJ-8038

    (Approval document / Penetration)

    English

  • F-C-2515

    (Approval document / Penetration)

    English

  • W-L-2677

    (Approval document / Penetration)

    Max. 2" electrical nonmetallic tubing (ENT)

    English

    Download File [316.2 kB]
  • W-J-8068

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set through Firestop Sleeve Kit

    English

    Download File [453.2 kB]
  • W-L-2694

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [404.9 kB]
  • F-A-1170

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [691.6 kB]
  • F-B-0005

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank CFS-CID M & P (6" concrete)

    English

    Download File [1.4 MB]
  • W-J-2332

    (Approval document / Penetration)

    Max. 2" electrical non-metallic tubing (ENT)

    English

    Download File [74.9 kB]
  • W-L-4087

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [335.2 kB]
  • W-J-1259

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [104.6 kB]
  • C-AJ-0155

    (Firestop System Details / UL Detail Drawing)

    Max 30" x 30" Blank opening with CFS-COS Firestop Composite Sheet (rigid foil-faced intumescent sheet with stainless steel backing) (min. 4-1/2" concrete) (4 hour)

    English

    Download File [198.6 kB]
  • ASSET_DOC_LOC_8593777

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [293.6 kB]
  • C-AJ-7199

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [355.3 kB]
  • F-A-8047

    (Firestop System Details / UL Detail Drawing)

    Single HVAC Line Set through CFS-DID Firestop Drop-In Device 3" MD or C

    English

    Download File [265.7 kB]
  • W-J-8068

    (Firestop System Details / UL Detail Drawing)

    HVAC line set through Firestop Sleeve Kit

    English

    Download File [95 kB]
  • F-B-2062

    (Firestop System Details / UL Detail Drawing)

    Nominal 8" or 10" XFR pipe (c,v) (6" concrete)

    English

    Download File [122.2 kB]
  • F-A-5062

    (Approval document / Penetration)

    Max. 2" steel or copper pipe with nom. 1-1/2" thickness cellular glass (foamglass) insulation (4-1/2" concrete) (CP 680-P Cast-In Device)

    English

    Download File [86.6 kB]
  • W-J-8055

    (Approval document / Penetration)

    English

    Download File [110.5 kB]
  • C-AJ-7195

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [166.7 kB]
  • F-E-3021

    (Approval document / Penetration)

    Structural cement-fiber panel and steel truss floor-ceiling assembly for max 1" diameter cable bundle through penetrant.

    English

    Download File [80.1 kB]
  • TP-506

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [201.2 kB]
  • W-L-1518

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [95.9 kB]
  • C-BJ-8038

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • W-L-2766

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [100.2 kB]
  • W-J-2332

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" electrical non-metallic tubing (ENT)

    English

    Download File [157.5 kB]
  • F-B-2063

    (Approval document / Penetration)

    Max. 4" PVC, CPVC, or ABS (Concrete Floor or Hollow-Core Floor) inside optional Gypsum Chase Wall.

    English

    Download File [80 kB]
  • F-C-2515

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • TP-572

    (Firestop System Details / UL Detail Drawing)

    Through penetration systems for non-rated smoke partitions using CP 572

    English

    Download File [251.3 kB]
  • W-J-5190

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1/2" PEX tubing with 3/4" thick AB/PVC pipe insulation (AS=1/4" to 7/8")

    English

    Download File [135.1 kB]
  • W-L-1597

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [623.1 kB]
  • CAD Detail (PDF) CT-L03-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-PS07-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) PL-SA02-C

    (CAD/BIM Typicals)

    English

  • Fastening to Steel Strut to Steel

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-PS56-C

    (CAD/BIM Typicals)

    English

  • Spec Section 26 05 29 for Hanger Supports for Electrical Systems

    (Specification Text)

    English

  • CAD Detail (PDF) CT-L07-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C09-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TP50-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-TR52-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-PS01-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP51-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-D50-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BF02-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-BC53-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TR53-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-BPS02-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP07-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F03-C

    (CAD/BIM Typicals)

    English

  • Fastening to Steel Decking

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC08-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR13-S

    (CAD/BIM Typicals)

    English

  • Fastening to Steel Grating

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-GP56-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TP50-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR57-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F51-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F10-C_S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC01-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR54-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TP04-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-P17-CS

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR50-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC05-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F06-C_S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP04-C

    (CAD/BIM Typicals)

    English

  • Fastening to Steel Grounding

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR61-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TR04-S

    (CAD/BIM Typicals)

    English

  • Spec Section 05 43 00 for Slotted Channel Framing

    (Specification Text)

    English

  • CAD Detail (PDF) P-GP11-NA

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR09-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC52-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-D53-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP11-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-BPS52-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-BC01-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR02-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C03-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C50-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-L04-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-PS51-C

    (CAD/BIM Typicals)

    English

  • Spec Section 05 50 60 for Pre-Engineered Modular Systems

    (Specification Text)

    French

  • CAD Detail (PDF) EI-PS55-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-L06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C10-S

    (CAD/BIM Typicals)

    English

  • HCS_Spec for Concrete Monitoring (Canada English).docx

    (Specification Text)

    Specification Text for Concrete Monitoring (Canada)

    English

  • CAD Detail (PDF) CT-C05-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TP51-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-TR53-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-BPS54-NA

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) (CA-EN) for Decking

    (CAD/BIM Typicals)

    English

  • CAD Detail (DWG) (CA-EN) for Decking

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP50-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-D51-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BF01-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR07-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-BC56-S

    (CAD/BIM Typicals)

    English

  • Spec Section 22 05 29 for Hanger Supports for Plumbing and Piping Equipment

    (Specification Text)

    French

  • CAD Detail (PDF) P-TR51-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-BPS01-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP06-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F04-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC07-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR14-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-P06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TP23-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR56-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F50-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F11-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR55-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TP21-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-P16-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR15-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-F05-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP05-C

    (CAD/BIM Typicals)

    English

  • Spec Section 26 05 29 for Hanger Supports for Electrical Systems

    (Specification Text)

    French

  • CAD Detail (PDF) CT-TR62-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-TR25-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) P-GP06-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR08-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-BC53-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-D52-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-GP11-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-BPS53-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EI-TR54-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-TR01-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C04-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-C11-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) CT-L05-S

    (CAD/BIM Typicals)

    English

  • SDI DDM03 Appendix VII with Hilti Screws

    (Approval document)

    English

  • CAD Detail (PDF) EI-PS53-C

    (CAD/BIM Typicals)

    English

  • Fastening to Steel Electrical Connections

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-GP54-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete Over Metal Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Cable Tray Supports, MI Details

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-Complete Set

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TR03-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Low Voltage Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Concrete Over Metal Deck, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TR53-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Equipment Supports, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-BC02-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-C05-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete Floor, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EQP-50-C

    (CAD/BIM Typicals)

    English

  • Quickstart Guide for PR 30-HVS Rotating Laser

    (Brochure)

  • CAD Detail (PDF) TD-P-TP01-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Low Voltage Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Piping Supports, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-F16-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete Over Metal Deck, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) OHG-MED01- C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) OHG-COMM50-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete/Block Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-F06-S

    (CAD/BIM Typicals)

    English

  • Common Construction Joints Firestop Schedule

    (Specification Text)

    English

  • CAD Details (PDF) for Piping Supports, MQ Details

    (CAD/BIM Typicals)

    English

  • Product Data Sheet for CB-G MG Multipurpose Grout

    (Technical information / Product data sheet)

    French

  • CAD Detail (PDF) TD-P-TP01-S

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Low Voltage Penetrations Through Concrete Floor, Concrete Wall, or Block Wall, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EQP-51-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete Over Metal Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-BC52-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-BC52-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Equipment Supports, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Concrete Over Metal Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Low Voltage Penetrations Through Concrete Floor, Concrete Wall, or Block Wall, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TR03-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-F06-C

    (CAD/BIM Typicals)

    English

  • Common Through Penetrations Firestop Schedule

    (Specification Text)

    English

  • Product Data Sheet for CB-G MG Multipurpose Grout

    (Technical information / Product data sheet)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete Over Metal Deck, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-GP04-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-GP54-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete Floor, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Cable Tray Supports, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-C55-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TR53-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • Product Data Sheet for Shower and Floor Drain

    (Technical information / Product data sheet)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Concrete/Block Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TR53-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Integrated Floor Systems, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-BC02-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-C05-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete Floor, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EQP-03-C

    (CAD/BIM Typicals)

    English

  • Customer Flyer for PR 2-HS Rotating Laser

    (Brochure)

  • CAD Details (DWG) for Low Voltage Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-GP54-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Platforms, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-F16-S

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete Over Metal Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) OHG-COMM52-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) OHG-COMM51-S

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete/Block Wall, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-F06-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Piping Supports, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TP51-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Low Voltage Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) EQP-01-NA

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete Over Metal Deck, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-BC52-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-BC52-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical and Instrumentation Stands, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Concrete Floor, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Low Voltage Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TP51-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-F06-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete/Block Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-GP04-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TP01-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete Floor, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Cable Tray Supports, MQ Details

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-C55-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TR53-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • Product Data Sheet for CB-G PG Precision Grout

    (Technical information / Product data sheet)

    French

  • CAD Details (DWG) for Electrical Penetrations Through Concrete/Block Wall, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TR03-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Overhead Grid Systems, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-C55-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • Customer Flyer for PR 2-HS Rotating Laser

    (Brochure)

  • CAD Detail (PDF) EQP-02-NA

    (CAD/BIM Typicals)

    English

  • Customer Flyer for PR 30-HVS Rotating Laser

    (Brochure)

  • CAD Detail (PDF) PL-SA03-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-GP54-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Platforms, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-GP04-C

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete Floor, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) PL-BC50-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) IFS-FT51-C

    (CAD/BIM Typicals)

    English

  • Product Data Sheet for CB-G PG Precision Grout

    (Technical information / Product data sheet)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-Complete Set

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Piping Supports, MI Details

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TP51-S

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete/Block Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-BC02-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-C05-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical and Instrumentation Stands, MI Library

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Concrete Floor, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Low Voltage Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TP51-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-F16-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations Through Concrete/Block Wall, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-F16-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-TP01-S

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Mechanical Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations, 1, 2 or 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Cable Tray Supports, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-CT-C05-S

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-BC02-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Electrical Penetrations Through Concrete/Block Wall, 3 Hour

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Electrical Penetrations Through Gypsum Wall, 1 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-TR03-C

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Overhead Grid Systems, MQ Library

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-C55-S

    (CAD/BIM Typicals)

    English

  • Customer Flyer for PR 30-HVS Rotating Laser

    (Brochure)

  • CAD Details (DWG) for Mechanical Penetrations Through Gypsum Wall, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) IFS-EQP50-C

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) PL-BC01-NA

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for Mechanical Penetrations Through Concrete Floor, 2 Hour

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) TD-P-GP04-S

    (CAD/BIM Typicals)

    English

  • Commercial Building Metal deck & Bar Joist (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Installation Troubleshooting Guide for CFP-SP WB Fire Finish

    (Reference document)

    Detailed installation troubleshooting guide for CFP-SP WB fire finish.

    English

  • Residential Wood (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • CAD Details (DWG) for Top and Bottom-of-Wall Joint for Flat Deck, 2 Hour

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Commercial Building Metal deck (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Residential Building Flat deck (CA-EN)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Top-of-Wall Joint for Concrete Over Metal Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • Residential Building Hollow Core (CA-EN)

    (CAD/BIM Typicals)

    English

  • Commercial Building Metal deck (CA-EN)

    (CAD/BIM Typicals)

    English

  • Healthcare Building Metal deck (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Residential Building Hollow Core (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Healthcare Building Metal deck (CA-EN)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for Top and Bottom-of-Wall Joint for Flat Deck, 2 Hour

    (CAD/BIM Typicals)

    English

  • Common Through Penetrations Firestop Schedule

    (Specification Text)

    English

  • Residential Wood (CA-EN)

    (CAD/BIM Typicals)

    English

  • Common Construction Joints Firestop Schedule (Excel)

    (Specification Text)

    English

  • Commercial Building Metal deck & Bar Joist (CA-EN)

    (CAD/BIM Typicals)

    English

  • UL Listing (CA-EN) for HCI-WF/MD, HDI, HDV, Kwik Bolt 3, Kwik Bolt-TZ, and KBV for Pipe Hangers

    (Approval document / FM (Factory Mutual))

    English

  • Residential Building Flat deck (CA-EN)

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • Hilti Certificate 2.2 2008565 8.8 AM8X3000

    (Inspection document / 2.2 Inspection document)

    English

  • Hilti Certificate 2.2 333157 5.8 HAS-E-F M16X125 348

    (Inspection document / 2.2 Inspection document)

    English

  • Hilti Certificate 2.2 387070 5.8 HIT-V M20X380

    (Inspection document / 2.2 Inspection document)

    English

    English

  • Hilti Certificate 2.2 407495 8.8 AM6X1000

    (Inspection document / 2.2 Inspection document)

    English

    English

  • Hilti Certificate 2.2 409556 5.8 HIT-V-F M12X120

    (Inspection document / 2.2 Inspection document)

    English

    English

  • Technical Manual for ETA-13/0516 for CFS-T cable transit system for penetrations

    (Technical information / ETA)

    Technical Manual for ETA-13/0516 for CFS-T cable transit system for penetrations issued by Hilti in 07/2013

    English

    Download File [6.5 MB]
  • VOC_SCAQMD and EPA24_CFS-F SOL_EN

    (HSE Information / LEED / VOC)

    VOC_SCAQMD and EPA24_CFS-F SOL_EN

    English

  • VOC_Test_Report_CDPH_HIT-RE 500 V3_EN

    (HSE Information)

    VOC_Test_Report_CDPH_HIT-RE 500 V3_EN

    English

    Download File [218.9 kB]
  • VOC_AgBB_HIT-RE 100_EN

    (HSE Information)

    VOC_AgBB_HIT-RE 100_EN

    English

    Download File [173.5 kB]
  • VOC_AgBB_HIT-RE 10_EN

    (HSE Information)

    VOC_AgBB_HIT-RE 10_EN

    English

  • VOC_AgBB_HIT-RE 500 V3 _EN

    (HSE Information)

    VOC_AgBB_HIT-RE 500 V3 _EN

    English

    Download File [174.7 kB]
  • VOC_French Label_HIT-RE 100_EN

    (HSE Information)

    VOC_French Label_HIT-RE 100_EN

    English

    Download File [428.7 kB]
  • VOC_French Label_HVU 2_EN

    (HSE Information)

    VOC_French Label_HVU 2_EN

    English

    Download File [275.6 kB]
  • EPD_HIT-HY 200-A_EN

    (HSE Information)

    EPD_HIT-HY 200-A_EN

    English

  • Technical data HAC-30 with MQM wing nut

    (Technical information / Technical Information)

    Tech.Data of HAC-30 in combination w/ MQM wing nuts

    English

    Download File [3.4 MB]
  • Texte de spécification - HCS

    (Specification Text)

    French

  • CFS-EOS QS Application Guideline (CA-FR)

    (Technical information / Operating Instruction)

    French

    Download File [12.2 MB]
  • Corrosion handbook

    (Documentation)

    Corrosion handbook

    English

    Download File [2.6 MB]
  • ETA_Modulare_Schienensysteme_V1.4_de

    (Approval document / ETA)

    ETA

    German

    Download File [14.2 MB]
  • HCS White Paper on Maturity Method (French)

    (Brochure)

    White Paper on Maturity Method (FR)

  • CAD Details (PDF) for MEP Anchor Supports

    (CAD/BIM Typicals)

  • CAD Details (DWG) for MEP Anchor Supports

    (CAD/BIM Typicals)

  • CAD Details (DWG) for Post-Installed Adhesive Anchors

    (CAD/BIM Typicals / Auto CAD drawing file)

    Typical details and general notes for post-installed adhesive anchors.

    English

    Download File [521.9 kB]
  • CAD Details (DWG) for Post-Installed Mechanical Anchors

    (CAD/BIM Typicals / Auto CAD drawing file)

    Typical details and general notes for post-installed mechanical anchors.

    English

    Download File [257.1 kB]
  • Confirmation_LEED_V4.1_HIT-RE 500 V3_102020

    (HSE Information)

    English

    Download File [238.6 kB]
  • Confirmation_LEED_V4_HIT-RE 100_112015

    (HSE Information)

    English

    Download File [199.7 kB]
  • Confirmation_LEED_V4_HIT-RE 10_102017

    (HSE Information)

    English

  • Confirmation_LEED_V4_HVU 2_032017

    (HSE Information)

    English

    Download File [223.9 kB]
  • Confirmation_LEED_HVU-TZ_LEED_062009

    (HSE Information)

    English

  • Anchor Selector Chart

    (Brochure)

  • ULc_E505298_X-MW-ALH27_X-MW-ALH32_Cables-Conduits_2021-06-09_en

    (Approval document)

    English

  • UL-CAN_E505298_X-MW-ALH27_X-MW-ALH32_Cables-Conduits_2021-06-09_en

    (Approval document / UL (Underwriter Laboratories))

    UL approval for Hilti X-MW-ALH27, X-MW-ALH32 fastener for fastening of cables and conduits, delivered by UL on June 9, 2021

    English

    Download File [96 kB]
  • UL_E517614_X-MW-ALH27_X-MW-ALH32_X-MW-MX_Luminaire-Fittings_2021-06-09_en

    (Approval document)

    English

    Download File [94.5 kB]
  • UL-Can_E517614_X-MW-ALH27_X-MW-ALH32_X-MW-MX_Luminaire-Fittings_2021-06-09_en

    (Approval document)

    English

    Download File [95.8 kB]
  • Installation Guide for CP 617 Firestop Putty Pads_SP

    (Reference document / Operating Instruction)

    Detailed installation instructions for the CP 617 Firestop Putty Pad

    Spanish

    Download File [730.6 kB]
  • Installation Guide for CP 617 Firestop Putty Pads_ENG

    (Reference document / Operating Instruction)

    Detailed installation instructions for the CP 617 Firestop Putty Pad

    English

    Download File [720.4 kB]
  • Installation Guide for CP 617 Firestop Putty Pads_FR_CA

    (Reference document / Operating Instruction)

    Detailed installation instructions for the CP 617 Firestop Putty Pad

    French

    Download File [726 kB]
  • X-DFB, X-EMTC Data Sheet

    (Technical information)

    English

  • X-EAS-FE MX Data Sheet

    (Technical information)

    English

  • X-FB Data Sheet

    (Technical information)

    English

  • Platform Typicals

    (CAD/BIM Typicals)

  • X-W6-12-14 B3 Performance Letter

    (Technical information / Technical Information)

    English

  • LEEDv4.1 (CDPH) Emissions Report_CFS-COS

    (Schematic / LEED)

    Download File [340.8 kB]
  • UL listing Hilti AG Sprinkler

    (Approval document / UL (Underwriter Laboratories))

    UL approved EX15279

    English

    Download File [439.6 kB]
  • Technical Bulletin for HIT-RE 500 V3 with large annular gap

    (Technical information / Technical Information)

    English

    Download File [280.6 kB]
  • CAD Details (DWG) for HAC-40 EDGE Lite

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC-50 EDGE Lite also includes HAC-T50 EDGE Lite details (serrated channel profile)

    (CAD/BIM Typicals)

    English

  • CAD Details for HAC-50 EDGE includes HAC-50 EDGE (EDGE C, S EDGE, & S EDGE C)

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC CRFoS U - Rebar Face of Slab includes HAC-50, HAC-60, and HAC-70 channel profiles

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC-30

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC-T50 EDGE Lite Also includes HAC-50 EDGE Lite details (smooth channel profile)

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HBC-B to be used with HAC-30 anchor channels

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HBC-C and HBC-C-N to be used with HAC-40, HAC-50, HAC-60, and HAC-70 (smooth channels profiles)

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HBC-T (Serrated T-bolts) to be used with HAC-T50, HAC-T70 and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC Includes HAC-40, HAC-50, HAC-60, and HAC-70 channel profiles

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC-40 EDGE Lite

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC-50 EDGE Lite also includes HAC-T50 EDGE Lite details (serrated channel profile)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC-50 EDGE includes HAC-50 EDGE (EDGE C, S EDGE, & S EDGE C)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC CRFoS U - Rebar Face of Slab includes HAC-50, HAC-60, and HAC-70 channel profiles

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC-30

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HAC-T50 EDGE Lite Also includes HAC-50 EDGE Lite details (smooth channel profile)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) (CA-EN) for MEP Anchor Supports

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) (CA-EN) for MEP Anchor Supports

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HBC-B to be used with HAC-30 anchor channels

    (CAD/BIM Typicals)

    English

  • CAD Detail (PDF) for HBC-C and HBC-C-N to be used with HAC-40, HAC-50, HAC-60, and HAC-70 (smooth channels profiles)

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC Includes HAC-40, HAC-50, HAC-60, and HAC-70 channel profiles

    (CAD/BIM Typicals)

    English

  • CAD Details (DWG) for HAC-T (serrated Channel) Includes HAC-T50, HAC-T70, and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)

    (CAD/BIM Typicals)

    English

  • CAD Details (PDF) for HBC-T (Serrated T-bolts) to be used with HAC-T50, HAC-T70 and HAC-T50 EDGE (EDGE C, S EDGE, & S EDGE C)

    (CAD/BIM Typicals)

    English

  • Abrasives Selector Card

    (Brochure)

    Download File [2.6 MB]
  • CAD Details (Simplified) (CA-EN) (PDF) for Smoke and Acoustic Penetrations and Joints

    (CAD/BIM Typicals)

    English

  • CAD Details (Simplified) (CA-EN) (PDF) for Joints

    (CAD/BIM Typicals)

    English

  • CAD Details (Simplified) (CA-EN) (PDF) for Floor Penetrations

    (CAD/BIM Typicals)

    English

  • CAD Details (Simplified) (CA-EN) (DWG) for Joints

    (CAD/BIM Typicals)

    English

  • CAD Details (Simplified) (CA-EN) (DWG) for Floor Penetrations

    (CAD/BIM Typicals)

    English

  • CAD Details (Simplified) (CA-EN) (PDF) for Wall Penetrations

    (CAD/BIM Typicals)

    English

  • ACI-349 Approval for KB-TZ2 Expansion Anchor

    (Technical information / ACI)

    English

    Download File [424 kB]
  • CFS-TTS Field Acoustical Field Testing Report

    (Test Report / Test Report)

    English

    Download File [2 MB]
  • Product Technical Guide Supplement for HRD-H Plastic Frame Anchor, English

    (Technical information)

    English

    Download File [448.3 kB]
  • ABS Approval 21-2146145-PDA for stainless steel powder-actuated X-CR, X-R and X-ST fasteners

    (Approval document / ABS)

    American Bureau of Shipping Approval for general purpose fasteners X-CR and X-R and threaded studs X-ST, delivered by ABS on August 2, 2021

    English

    Download File [111 kB]
  • LEED Information for Drywall Screws

    (Documentation / LEED)

    English

    Download File [122.9 kB]
  • Approval Document

    (Approval document)

    Download File [220.1 kB]
  • VOC_AgBB_CP648_EN

    (HSE Information / VOC)

    Certificate_VOC AgBB/DIBt for CP 648 firestop wrap strip for penetrations delivered by Eurofins on 28.12.2010

    English

    Download File [261.4 kB]
  • LEED Information for HVU2 Injectable Mortar

    (Documentation / LEED)

    English

    Download File [223.9 kB]
  • Productivity Component Wall Chart

    (Brochure / No approval)

    Download File [3.4 MB]
  • LEED Information for Hilti GX and BX Nails

    (Documentation / LEED)

    English

    Download File [159 kB]
  • Product Technical Guide Supplement for HRD-H Plastic Frame Anchor, French

    (Technical information)

    English

    Download File [587.1 kB]
  • California Proposition 65 Warning CFS-T

    (Approval document)

    English

    Download File [138.4 kB]
  • X-CR Fasteners - LEED Information

    (Documentation)

    English

    Download File [120.9 kB]
  • Product Data Sheet (US_CA_ENG) for CP 660 Firestop Foam

    (Technical information / Product data sheet)

    English

    Download File [383.3 kB]
  • Product Technical Guide Supplement for Kwik HUS-EZ I and E Screw Anchors

    (Technical information / Technical Information)

    English

    Download File [8.3 MB]
  • Product Technical Guide Supplement for KWIK-CON+ Concrete and Masonry Screw

    (Technical information / Technical Information)

    English

    Download File [7.5 MB]
  • Product Technical Guide Supplement for HLC Sleeve Anchor

    (Technical information / Technical Information)

    English

    Download File [2.5 MB]
  • Product Technical Guide Supplement for Cast-In Anchors KCS-WF

    (Technical information / Technical Information)

    English

  • Product Technical Guide Supplement for HDI-P Flush Anchors

    (Technical information / Technical Information)

    English

    Download File [1.3 MB]
  • Product Technical Guide Supplement for HDI+, HDI-L+, HDI and HDI-S Flush Anchors

    (Technical information / Technical Information)

    English

    Download File [2.7 MB]
  • Product Technical Guide Supplement for HVU2 Adhesive Capsule System

    (Technical information / Technical Information)

    English

    Download File [23.4 MB]
  • Product Features & Technical Data - Strut Beam Clamp MQT-U

    (Approval document)

    Download File [160.6 kB]
  • MT Slider Plate Mechanical Properties Technical Statement

    (Reference document / Product data sheet)

  • MT Long Goods LEED Information

    (Submittal / LEED)

    English

    Download File [256.6 kB]
  • Substitution Letter for HSL-3 to HSL4

    (Documentation)

    English

    Download File [59.1 kB]
  • Instructions for use_HUD-2

    (Documentation)

    English

    Download File [2.9 MB]
  • Substitution Letter for KB-TZ to KB-TZ2

    (Technical information / Technical Information)

    Download File [98 kB]
  • Substitution Letter for KB3 CS to KB1 CS

    (Technical information / Technical Information)

    Download File [97.3 kB]
  • Substitution Letter for KB-TZ to KB1

    (Technical information / Technical Information)

    Download File [97.7 kB]
  • Substitution Letter for KB3 to KB-TZ2

    (Technical information / Technical Information)

    Download File [98.3 kB]
  • UL 1598_Luminaire_MW imperial

    (Approval document / Approval)

    Download File [325 kB]
  • UL 2239 Conduit and cable_MW imperial

    (Approval document / Approval)

    Download File [322.5 kB]
  • Confirmation_LEED_4.1_HIT-HY-200-A V3_EN

    (HSE Information / LEED)

    English

    Download File [215 kB]
  • ICC ESR-4006 for Kwik Cast KCS-WF/MD Headed Cast-In Specialty Inserts in Cracked and Uncracked Concrete

    (Approval document / ICC-ESR)

    Headed cast-in specialty insert used to resist static, wind and seismic tension and shear loads in cracked and uncracked concrete; IBC 2015 compliant.

    English

  • Product Technical Guide Supplement (CA-FR) for HVU2 Adhesive Capsule System

    (Technical information / Technical Information)

    French

    Download File [1.2 MB]
  • CAD Details (PDF) for Non-Fire Rated Smoke Partition CS-S SA Light Smoke and Acousitic Sealant

    (CAD/BIM Typicals)

    English

    Download File [291.1 kB]
  • CAD Details (DWG) for Non-Fire Rated Smoke Partitions CS-S SA LIGHT Smoke and Acoustic Sealant

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [565.2 kB]
  • Hilti BX 3-SCT Test instructions_December 2021

    (Technical information)

    Hilti BX 3-SCT Test instructions_12-2021

    English

    Download File [4 MB]
  • CAD Details (DWG) for various penetrations with CPF-ES ENDO-SHIELD

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [685.1 kB]
  • Pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD

    French

    Download File [7.4 MB]
  • Pre-built submittal for T-ratings with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal for T-Ratings using HILTI CFP-ES ENDO-SHIELD

    English

    Download File [9.4 MB]
  • Product Data Sheet for CFP-ES ENDO-SHIELD

    (Technical information / Product data sheet)

    French

    Download File [289.7 kB]
  • Pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal for penetrants wrapped in HILTI CFP-ES ENDO-SHIELD

    English

    Download File [5.3 MB]
  • Pre-build submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD

    English

    Download File [4.4 MB]
  • Pre-built submittal for large metallic boxes with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal large metallic boxes treated with HILTI CFP-ES ENDO SHIELD

    French

    Download File [4.6 MB]
  • Pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD

    (Approval document / Approval)

    pre-built submittal for penetrants protected with HILTI CFP-ES ENDO-SHIELD

    French

    Download File [3 MB]
  • LEEDv4.1 (CDPH) Emissions Report_CFP-ES ENDO-SHIELD

    (Schematic / LEED)

    English

    Download File [236.8 kB]
  • CAD Details (PDF) for various penetrations with CFP-ES ENDO-SHIELD

    (CAD/BIM Typicals)

    English

    Download File [732.7 kB]
  • Technical Manual for ETA-10/0109 CFS-F FX firestop foam for penetrations

    (Technical information)

    Technical Manual for ETA-10/0109 CFS-F FX Firestop Foam

    English

  • ETA-12/0084 HIT-HY-200-R Anchor EC2 & TR055 50 years

    (Approval document / Seismic / ETA)

    ETA 12/0084 for HIT-HY 200-R injection mortar and standard anchor rods for anchoring in cracked and uncracked concrete and seismic C1, issued by DIBt on 14/04/2015

    English, German

    Download File [3.4 MB]
  • CoCP 2873-CPR-201-66 HIT-RE 500 V4 anchor for ETA 20-0541

    (Certificate)

    CoCP_2873-CPR-201-66_01.04.2021_HIT-RE 500 V4 anchor for ETA-20-0541_21.11.2020

    English, French, German

  • Spec Section 2X 05 29 for Cable Hanging System (CA-FR)

    (Specification Text)

    French

  • Product Data Sheet for CFS-TTS MD P & CFS-TTS MD C (CA-FR)

    (Technical information / Product data sheet)

    French

    Download File [959.6 kB]
  • SMACNA Test & Verification Report for X-MW Wire Hanger System

    (Certificate / UL (Underwriter Laboratories))

    English

    Download File [126.7 kB]
  • Anchor Channel Design Guide

    (Technical information / Technical Information)

    Design Guide for Hilti Anchor Channels

    English

    Download File [9.1 MB]
  • Technical Datasheet HAC-C-P Anchor Channels

    (Technical information / Technical Information)

    Technical Datasheet HAC-C-P Anchor Channels

    English

  • CoCP 2873-CPR-201-56 HIT-HY 200-A / R V3 for ETA 19-0601

    (Certificate)

    English, German

    Download File [797 kB]
  • Electrical continuity test for MT Modular Support System_XE-21-48

    (Certificate / Certificate of Conformity)

    CoC for MT Modular Support System to IEC/ EN 61537

    English

    Download File [256.3 kB]
  • Wire Hanger System Portfolio

    (Brochure)

    Download File [1.7 MB]
  • ICC ESR-3963 for HIT-HY 200 Adhesive Anchors in Masonry

    (Approval document / ICC-ESR)

    Adhesive anchoring system to resist static, wind and seismic loads in fully grouted concrete and masonry walls in accordance with IBC 2015.

    English

  • Substitution letter HY 200 V3 (CA-EN)

    (Documentation / Technical Information)

    English

    Download File [19.7 kB]
  • Wire Hanger System MW - Technical Guide

    (Technical information / Technical Information)

    English

    Download File [5.4 MB]
  • Product Technical Guide Supplement for Seismic Bracing per NFPA January 2022

    (Technical information / Technical Information)

    English

    Download File [1.8 MB]
  • Fiche technique du produit pour CP 619T

    (Technical information / Product data sheet)

    French

    Download File [255.7 kB]
  • DOC CE Hilti PP EY-GU grey

    (Certificate / Declaration of Conformity)

    Declaration of Conformity for PP EY-GU tinted grey

    English

    Download File [92.1 kB]
  • Acoustics Performance Test Report for Joint CS-S-SA Light, No. TL20-402

    (Technical information / Test Report)

    English

    Download File [371.5 kB]
  • HI/PF 120-07

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set through Mass Timber Floor or Wall

    English

    Download File [462.1 kB]
  • HI/PF 120-10

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal 6" steel, or Iron Pipe with max 2" glass fiber through Mass Timber Floor or Wall.

    English

    Download File [438.9 kB]
  • DOC CE Hilti PP EY-GU blue

    (Certificate / Declaration of Conformity)

    Declaration of Conformity for PP EY-GU tinted blue

    English

  • FW-D-0042

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=2")

    English

    Download File [94.2 kB]
  • FW-D-0101

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [93.6 kB]
  • Powder-actuated fasteners and fastening screws in steel construction, Reprint from Stahlbau-Kalender 2019, Ernst & Sohn

    (Reference document)

    English

    Download File [7 MB]
  • ABS Type Approval 21-2140400-PDA for S-BT fastening system in off-shore and shipbuilding application

    (Approval document / ABS)

    American Bureau of Shipping Approval for S-BT screw-in stainless steel and carbon steel threaded fasteners, delivered by ABS on August 1, 2021

    English

  • HI/PF 120-10

    (Approval document / Penetration)

    Nominal 6" steel, or Iron pipe insulated with Max 2" glass fiber through Mass Timber Floor or Wall

    English

    Download File [857.5 kB]
  • HI/PF 120-08

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through Mass Timber Floor or Wall.

    English

    Download File [556.5 kB]
  • Electrical continuity test for Grating Fastening Solutions_XE-21-47

    (Certificate / Certificate of Conformity)

    CoC for Grating Fastening Solutions according to IEC/ EN 61537

    English

    Download File [216.2 kB]
  • DOC CE Hilti PP EY-CA

    (Certificate / Declaration of Conformity)

    Declaration of Conformity for PP EY-CA

    English

  • DOC CE Hilti PP EY-HAS

    (Certificate / Declaration of Conformity)

    Declaration of Conformity for PP EY-HA S

    English

  • DIBT_Z-21.8-2137_HUS4_reusability_122021_de

    (Approval document / aBG)

    German

  • WW-D-0270

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Optional one side installation) (Max. JW=2")

    English

    Download File [95 kB]
  • Acoustics Performance Test Report for Penetration CS-S-SA Light, No. TL20-406

    (Technical information / Test Report)

    English

    Download File [672 kB]
  • Electrical continuity test for Threaded Studs_XE-21-50

    (Certificate / Certificate of Conformity)

    CoC for Threaded Studs according to IEC/ EN 61537

    English

    Download File [233.9 kB]
  • HI/PF 120-07

    (Approval document / Penetration)

    HVAC Line Set through Mass Timber Floor or Wall.

    English

    Download File [631.5 kB]
  • Technical Manual for ETA-10/0292 and 10/0389 for CFS-ACR firestop acrylate sealant for penetrations

    (Technical information / ETA)

    Technical Manual for ETA-10/0292 and 10/0389 for CFS-ACR firestop acrylate sealant for penetrations issued by Hilti in 12/2021

    English

  • HW-D-0929

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")

    English

    Download File [93.7 kB]
  • FF-D-0155

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [94.2 kB]
  • WW-D-0269

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete or block wall Using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")

    English

    Download File [95.1 kB]
  • ASSET_DOC_LOC_16907462

    (Brochure)

  • DOC CE Hilti PP EY-GU red

    (Certificate / Declaration of Conformity)

    Declaration of Conformity for PP EY-GU red

    English

    Download File [90.1 kB]
  • HI/PF 120-09

    (Approval document / Penetration)

    Max. 2" PVC (Sch. 40) (Vented) through Mass Timber Floor or Wall

    English

    Download File [623.7 kB]
  • HI/PF 120-11

    (Approval document / Penetration)

    Nominal 6" steel, iron, copper, steel conduit, or emt (AS = min. 1/2" to max. 1-7/16") through Mass Timber Floor or Wall.

    English

    Download File [624.2 kB]
  • FF-D-0055

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

    Download File [95.8 kB]
  • LR Type Approval LR21394055TA for S-BT fastening system in off-shore, shipbuilding and industrial application

    (Approval document / Lloyds)

    Lloyd's Register Type Approval for S-BT screw-in stainless steel and carbon steel threaded fasteners and X-FCM-M, X-FCM-NG, X-FCM-R, X-FCM-R NG, X-FCS-R grating fasteners, delivered by LR on October 15, 2021

    English

    Download File [470.9 kB]
  • RINA Type Approval FPE278318CS/001 for S-BT-MR / -MF, S-BT-GR / -GF, S-BT-ER / -EF, X-FCM-R (NG), X-FCM-M (NG) and X-FCS-R fastening system in off-shore and shipbuilding application

    (Approval document)

    RINA Type Approval for screw-in stainless steel and carbon steel threaded fasteners S-BT-MR / -MF, S-BT-GR / -GF, electrical connectors S-BT-ER / -EF, grating fasteners X-FCM-R (NG), X-FCM-M (NG) and X-FCS-R, delivered by RINA on June 22, 2021.

    English

    Download File [108.1 kB]
  • HW-D-0930

    (Firestop System Details / UL Detail Drawing)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) optional one-sided install (Max. JW=2")

    English

    Download File [96.2 kB]
  • HI/PF 120-09

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal 2" PVC (Sch. 40) Vented through Mass Timber Floor or Wall.

    English

    Download File [496.5 kB]
  • HI/PF 120-11

    (CAD/BIM Typicals / Auto CAD drawing file)

    Nominal 6" steel, iron, copper, steel conduit, or emt (AS = min. 1/2" to max. 1-7/16") through Mass Timber Floor or Wall.

    English

    Download File [363.9 kB]
  • DOC CE Hilti PP EY_HAR

    (Certificate / Declaration of Conformity)

    English

  • ETA 17/0336 for HAC-C(-P) anchor channels with channel bolts (HBC)

    (Approval document / ETA)

    ETA 17/0336 for HAC-C(-P) anchor channels with channel bolts (HBC) delivered by DiBT

    German

  • DRS Selector Chart (EN)

    (Brochure)

  • HI/PF 120-08

    (Approval document / Penetration)

    Cable bundle (various cables) through Mass Timber Floor or Wall

    English

    Download File [753.6 kB]
  • Electrical continuity test for Oglaend Mekano Modular Support System_XE-21-49

    (Certificate / Certificate of Conformity)

    CoC for Oglaend Mekano Modular Support System according to IEC/ EN 61537

    English

    Download File [252.3 kB]
  • FW-D-1013

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

    Download File [22.1 kB]
  • HW-D-0634

    (Firestop System Details / UL Detail Drawing)

    Gypsum Wall to bottom of offset I beam with Z-bar extensions (Max. JW=1-1/2")

    English

    Download File [186.6 kB]
  • HW-D-0654

    (Approval document / Joint)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    English

    Download File [345.7 kB]
  • HW-D-0286

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

    Download File [609.1 kB]
  • HW-D-0209

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    English

    Download File [100.2 kB]
  • CW-D-2025

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated Tilt-up Concrete Panel Curtain Wall (Max. JW=8")

    English

    Download File [170.1 kB]
  • HI/BP 120-08 (CEJ 259P)

    (Approval document / Joint)

    Gypsum with EIFS Finish and Steel Framing (Max. JW=8")

    English

    Download File [574.4 kB]
  • HI/PHV 120-07 (CEJ 261P)

    (Approval document / Joint)

    Gypsum with Stone Finish and Steel Framing (Max. JW=8")

    English

    Download File [528.1 kB]
  • HW-D-0296

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    English

    Download File [126.7 kB]
  • FF-D-1039

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

  • HW-D-0540

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")

    English

    Download File [431.7 kB]
  • HW-D-1011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")

    English

    Download File [1.4 MB]
  • HI/BP 105-02 (CEJ 310P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8")

    English

    Download File [1.8 MB]
  • HI/BP 180-01 (CEJ 307P)

    (Approval document / Joint)

    Glass or Aluminum Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [711.2 kB]
  • BW-S-0023

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete floor (bottom of wall)

    English

    Download File [93.4 kB]
  • HW-D-0403

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

    Download File [113.5 kB]
  • FW-D-1012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=3-3/4")

    English

    Download File [111.9 kB]
  • HW-D-1002

    (Approval document / Joint)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [18.2 kB]
  • HW-D-1001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [186.9 kB]
  • HI/BP 165-02 (CEJ 315P)

    (Approval document / Joint)

    Gypsum with Cementitious Finish and Steel Framing (Max. JW=6")

    English

    Download File [487.5 kB]
  • BW-S-0023

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall to concrete floor (bottom of wall)

    English

    Download File [486.1 kB]
  • FF-D-1001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to concrete floor (floor to floor)

    English

  • HI/BP 135-01 (CEJ 245P)

    (Approval document / Joint)

    Concrete Panels with Steel Framing (Max. JW=8")

    English

    Download File [103.1 kB]
  • FW-D-1021

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [102.6 kB]
  • HI/BP 60-01 (CEJ 526P)

    (Approval document / Joint)

    Glass Spandrel with Aluminum Framing (vision glass at floor) (Max. JW=6")

    English

    Download File [103.6 kB]
  • FF-D-1012

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [77.2 kB]
  • FW-D-1046

    (Approval document / Joint)

    Concrete stair case to Concrete wall joint (Max. JW=3-1/2")

    English

    Download File [83.3 kB]
  • HI/BP 180-02 (CEJ 308P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8")

    English

    Download File [1.9 MB]
  • HW-D-1008

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")

    English

  • FF-D-1087

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint (Max. JW=3")

    English

    Download File [79.6 kB]
  • HW-D-0294

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (perpendicular) (Max. JW=1")

    English

    Download File [285.9 kB]
  • HW-D-0225

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")

    English

    Download File [28.9 kB]
  • HW-D-0636

    (Firestop System Details / UL Detail Drawing)

    Gypsum Shaft Wall to bottom of offset I beam with Z-bar extensions (Max. JW=1-1/2")

    English

    Download File [108.4 kB]
  • HW-D-0516

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")

    English

    Download File [63.8 kB]
  • FF-D-1026

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [20.4 kB]
  • CW-D-2025

    (Approval document / Joint)

    Insulated Tilt-up Concrete Panel Curtain Wall (Max. JW=8")

    English

    Download File [168.8 kB]
  • HW-D-0184

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [24.7 kB]
  • CW-D-1015

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=4")

    English

    Download File [220.6 kB]
  • FF-D-1013

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

    Download File [86 kB]
  • HI/BP 165-02 (CEJ 315P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Cementitious Finish and Steel Framing (Max. JW=6")

    English

    Download File [624.8 kB]
  • HW-D-0225

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")

    English

    Download File [93.9 kB]
  • BW-S-0001

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to Concrete floor (bottom-of-wall)

    English

    Download File [106.7 kB]
  • HW-D-0460

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)

    English

    Download File [41.6 kB]
  • FW-D-0042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=2")

    English

    Download File [393 kB]
  • HW-D-1011

    (Approval document / Joint)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")

    English

    Download File [193.6 kB]
  • FF-D-1047

    (Approval document / Joint)

    Concrete floor to floor joint

    English

  • FW-D-1001

    (Approval document / Joint)

    Concrete floor to concrete wall joint (Max. JW=6")

    English

  • CW-S-2031

    (Approval document / Joint)

    Granite Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HW-D-1003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")

    English

    Download File [150.3 kB]
  • BW-S-0001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to Concrete floor (bottom-of-wall)

    English

    Download File [246.1 kB]
  • FW-D-1043

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete stair case to Concrete wall joint (Max. JW=3-3/4")

    English

    Download File [134.7 kB]
  • HW-D-0342

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete floor (Max. JW=1")

    English

    Download File [96.1 kB]
  • CW-D-1018

    (Approval document / Joint)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=3")

    English

    Download File [186.7 kB]
  • HW-D-0181

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")

    English

    Download File [200.8 kB]
  • HI/PHV 120-11 (CEJ 265P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")

    English

    Download File [883.8 kB]
  • HW-D-0654

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    English

    Download File [244.7 kB]
  • HI/JS 120-05 (CEJ 127P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 6")

    English

    Download File [2.5 MB]
  • CW-S-2032

    (Approval document / Joint)

    Granite Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [115.4 kB]
  • HW-D-0286

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

    Download File [165 kB]
  • CW-S-1007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tilt-Up Concrete Panel Curtain Wall (Max JW = 6")

    English

    Download File [50.8 kB]
  • FF-D-1087

    (Approval document / Joint)

    Concrete floor to floor joint (Max. JW=3")

    English

    Download File [76.5 kB]
  • HW-D-0687

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top of wall) (parallel)(cantilevered runner) (Max. JW=1-1/2")

    English

    Download File [40.7 kB]
  • HW-D-0258

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")

    English

  • HW-D-1001

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [23.8 kB]
  • HW-D-0570

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (top-of-wall) (parallel) (Max. JW=1-1/2")

    English

    Download File [39.1 kB]
  • HW-D-0155

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [110.1 kB]
  • FF-D-1011

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

  • HW-D-0529

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [260.5 kB]
  • HI/JS 120-05 (CEJ 127P)

    (Approval document / Joint)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 6")

    English

    Download File [109.4 kB]
  • HW-D-0528

    (Approval document / Joint)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [600.1 kB]
  • HW-D-0516

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")

    English

    Download File [114.9 kB]
  • FF-D-1087

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint (Max. JW=3")

    English

    Download File [165.1 kB]
  • HW-D-0120

    (Approval document / Joint)

    Gypsum shaft wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")

    English

    Download File [138.7 kB]
  • FW-D-1047

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=2")

    English

    Download File [77.9 kB]
  • FF-D-1013

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [22.3 kB]
  • FW-D-1047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=2")

    English

    Download File [222.4 kB]
  • HW-D-0313

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes and joint (top-of-wall) (Max. JW=3/4")

    English

    Download File [201.8 kB]
  • HI/BP 120-07 (CEJ 244P)

    (Approval document / Joint)

    Concrete Panels with Steel Framing (Max. JW=8")

    English

    Download File [360 kB]
  • FW-D-1071

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [91.1 kB]
  • HI/PHV 120-09 (CEJ 263P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")

    English

    Download File [863.3 kB]
  • HI/BP 120-07 (CEJ 244P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete Panels with Steel Framing (Max. JW=8")

    English

    Download File [755.8 kB]
  • FW-D-1012

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=3-3/4")

    English

    Download File [20.7 kB]
  • HW-D-0268

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)

    English

    Download File [432.2 kB]
  • CW-S-2028

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [330.1 kB]
  • HW-D-0268

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)

    English

    Download File [95.4 kB]
  • HI/BP 120-04 (CEJ 425P)

    (Approval document / Joint)

    Gypsum wall with various facades. Steel framing starts and stops above and below floor (Nom. 2" cantilever)

    English

    Download File [148.4 kB]
  • HW-D-1002

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [95.3 kB]
  • HW-D-0285

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

  • FF-D-0055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [437.1 kB]
  • HW-D-0564

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Penetrations through flutes) (Max. JW=2")

    English

    Download File [354.1 kB]
  • HI/BP 165-01 (CEJ 314P)

    (Approval document / Joint)

    Gypsum with Brick Finish and Steel Framing (Max. JW=6")

    English

    Download File [432.5 kB]
  • FW-D-1012

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=3-3/4")

    English

    Download File [78.4 kB]
  • FF-D-0052

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

    Download File [63.2 kB]
  • HW-D-0516

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")

    English

    Download File [107 kB]
  • HI/PHV 120-11 (CEJ 265P)

    (Approval document / Joint)

    Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")

    English

    Download File [482.4 kB]
  • HI/BP 120-04 (CEJ 425P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall with various facades. Steel framing starts and stops above and below floor (Nom. 2" cantilever)

    English

    Download File [1.1 MB]
  • HW-D-1008

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-0539

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor (top-of-wall) (Max. JW=1-1/2")

    English

    Download File [104.1 kB]
  • FF-D-1039

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

  • HW-D-0292

    (Approval document / Joint)

    Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")

    English

    Download File [26.7 kB]
  • HI/PHV 120-06 (CEJ 260P)

    (Approval document / Joint)

    Gypsum with Stucco Finish and Steel Framing (Max. JW=8")

    English

    Download File [572 kB]
  • HI/JF 120-01

    (Approval document / Joint)

    Gypsum Wall to Fireproofed Column Vertical Joint (Max. JW = 1-1/2")

    English

    Download File [302.2 kB]
  • FW-D-1021

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [22.7 kB]
  • CW-S-2027

    (Approval document / Joint)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HI/BP 120-05

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with various facades. Steel framing starts and stops above and below floor (Max. JW=0") (Max. 2" cantilever)

    English

    Download File [1 MB]
  • HW-D-0295

    (Firestop System Details / UL Detail Drawing)

    Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    English

    Download File [180.6 kB]
  • HI/BP 150-01

    (Approval document / Joint)

    Glass spandrel with aluminum framing (vision glass at floor) (Max. JW=8")

    English

    Download File [126.8 kB]
  • CW-S-2053

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated Tilt-up Panel Curtain Wall (Max. JW=6")

    English

    Download File [227.8 kB]
  • FW-D-1046

    (Firestop System Details / UL Detail Drawing)

    Concrete stair case to Concrete wall joint (Max. JW=3-1/2")

    English

  • HI/PHV 120-07 (CEJ 261P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Stone Finish and Steel Framing (Max. JW=8")

    English

    Download File [2.9 MB]
  • HI/BP 120-01 (CEJ 246P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [1.1 MB]
  • FW-D-1021

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [100.8 kB]
  • HI/BP 120-01 (CEJ 246P)

    (Approval document / Joint)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [485.9 kB]
  • HI/PHV 120-08 (CEJ 262P)

    (Approval document / Joint)

    Gypsum with Brick Finish and Steel Framing (Max. JW=8")

    English

    Download File [526 kB]
  • CW-S-2030

    (CAD/BIM Typicals / Auto CAD drawing file)

    Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [1.2 MB]
  • HW-D-0286

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

    Download File [163.3 kB]
  • FF-D-1011

    (Approval document / Joint)

    Concrete floor to floor joint

    English

  • FW-D-1043

    (Approval document / Joint)

    Concrete stair case to Concrete wall joint (Max. JW=3-3/4")

    English

    Download File [83.3 kB]
  • HI/BP 180-02 (CEJ 308P)

    (Approval document / Joint)

    Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8")

    English

    Download File [651.4 kB]
  • HW-D-0403

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

    Download File [18.2 kB]
  • FF-D-1012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [179.5 kB]
  • HI/BP 165-03 (CEJ 316P)

    (Approval document / Joint)

    Gypsum with Plaster Finish and Steel Framing (Max. JW=6")

    English

    Download File [486.5 kB]
  • HW-D-0542

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (top-of-wall) (parallel) (Max. JW=3/4")

    English

    Download File [39.1 kB]
  • HW-D-0466

    (Approval document / Joint)

    Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)

    English

  • CJ-D-0004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to non-rated floor/roof deck

    English

    Download File [238.8 kB]
  • HW-D-0440

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. JW=2")

    English

    Download File [296.4 kB]
  • HI/JS 120-04 (CEJ 529P)

    (Approval document / Joint)

    Glass spandrel panel with aluminum framing (Max. JW=2") (25% vertical shear movement)

    English

    Download File [108.7 kB]
  • HW-D-0460

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)

    English

    Download File [192.7 kB]
  • BW-S-0023

    (Approval document / Joint)

    Gypsum shaft wall to concrete floor (bottom of wall)

    English

    Download File [88.6 kB]
  • HI/JS 120-04 (CEJ 529P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass spandrel panel with aluminum framing (Max. JW=2") (25% vertical shear movement)

    English

    Download File [2.4 MB]
  • CW-D-2026

    (Approval document / Joint)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")

    English

  • HW-D-0541

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4")

    English

    Download File [39.5 kB]
  • FF-D-1013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [105.8 kB]
  • HI/JF 120-01

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum Wall to Fireproofed Column Vertical Joint (Max. JW = 1-1/2")

    English

    Download File [1 MB]
  • HW-D-0292

    (Firestop System Details / UL Detail Drawing)

    Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")

    English

    Download File [189.2 kB]
  • FF-D-1039

    (Approval document / Joint)

    Concrete floor to floor joint

    English

  • CW-S-2031

    (CAD/BIM Typicals / Auto CAD drawing file)

    Granite Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HW-D-0258

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")

    English

    Download File [179.5 kB]
  • CW-S-2030

    (Approval document / Joint)

    Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [118.1 kB]
  • FW-D-1037

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=6")

    English

  • CW-D-1003

    (Approval document / Joint)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=6")

    English

  • HI/BP 120-08 (CEJ 259P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with EIFS Finish and Steel Framing (Max. JW=8")

    English

    Download File [804.8 kB]
  • HI/PHV 120-06 (CEJ 260P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Stucco Finish and Steel Framing (Max. JW=8")

    English

    Download File [858.9 kB]
  • FW-D-1043

    (Firestop System Details / UL Detail Drawing)

    Concrete stair case to Concrete wall joint (Max. JW=3-3/4")

    English

    Download File [189.1 kB]
  • HW-D-0225

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")

    English

    Download File [142.1 kB]
  • CW-S-2032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Granite Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [1.2 MB]
  • HI/BP 150-01

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass spandrel with aluminum framing (vision glass at floor) (Max. JW=8")

    English

    Download File [1.6 MB]
  • CW-S-2053

    (Approval document / Joint)

    Insulated Tilt-up Panel Curtain Wall (Max. JW=6")

    English

    Download File [104.8 kB]
  • FW-D-0041

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=1/2")

    English

    Download File [17.7 kB]
  • FF-D-1026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [101.1 kB]
  • HW-D-0540

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")

    English

    Download File [22.7 kB]
  • HI/BP 60-01 (CEJ 526P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with Aluminum Framing (vision glass at floor) (Max. JW=6")

    English

    Download File [705 kB]
  • HW-D-0466

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)

    English

    Download File [197.8 kB]
  • HW-D-0403

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

    Download File [165.5 kB]
  • HW-D-0545

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4")

    English

    Download File [278.2 kB]
  • FF-D-1011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [269.5 kB]
  • FW-D-1001

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to concrete wall joint (Max. JW=6")

    English

  • HW-D-0529

    (Approval document / Joint)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [648.6 kB]
  • HW-D-0285

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

    Download File [170.1 kB]
  • CW-S-2029

    (CAD/BIM Typicals / Auto CAD drawing file)

    Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HW-D-0540

    (Approval document / Joint)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")

    English

  • FW-D-1013

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

    Download File [99.3 kB]
  • HI/BP 135-01 (CEJ 245P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete Panels with Steel Framing (Max. JW=8")

    English

    Download File [866.4 kB]
  • HI/PHV 120-08 (CEJ 262P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Brick Finish and Steel Framing (Max. JW=8")

    English

    Download File [1.8 MB]
  • FW-D-1071

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [78 kB]
  • FW-D-1047

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=2")

    English

  • HW-D-0296

    (Firestop System Details / UL Detail Drawing)

    Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    English

    Download File [123.6 kB]
  • FW-D-1071

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=3")

    English

    Download File [166.6 kB]
  • HI/BPF 120-06 (CEJ 216P)

    (Approval document / Joint)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=6")

    English

    Download File [113.1 kB]
  • CW-D-1015

    (Approval document / Joint)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=4")

    English

    Download File [159 kB]
  • FF-D-0052

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [16.2 kB]
  • FF-D-1047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

  • HW-D-0538

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")

    English

    Download File [104.3 kB]
  • HI/BP 120-03 (CEJ 421P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall with various facades (Max. JW=9", including studs)

    English

    Download File [718.7 kB]
  • HW-D-0528

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [251.4 kB]
  • HW-D-0296

    (Approval document / Joint)

    Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    English

  • HW-D-0154

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [191.5 kB]
  • HW-D-0268

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)

    English

    Download File [89.6 kB]
  • HW-D-0569

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (top-of-wall) (perpendicular) (Max. JW=1-1/2")

    English

    Download File [40.4 kB]
  • FF-D-0052

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint

    English

    Download File [97.8 kB]
  • FW-D-1011

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

    Download File [78.4 kB]
  • BW-S-0001

    (Approval document / Joint)

    Gypsum wall to Concrete floor (bottom-of-wall)

    English

    Download File [375.8 kB]
  • HW-D-1008

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-1009

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-3/4")

    English

    Download File [230.1 kB]
  • HI/BP 120-03 (CEJ 421P)

    (Approval document / Joint)

    Gypsum wall with various facades (Max. JW=9", including studs)

    English

    Download File [120.1 kB]
  • HW-D-0294

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (perpendicular) (Max. JW=1")

    English

  • HW-D-0264

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (offset flutes) (Max. JW=1-1/2")

    English

    Download File [102.9 kB]
  • CW-S-2027

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HW-D-0285

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal roof deck (top-of-wall) (stuff/spray/stuff/spray) (Max. JW=2")

    English

    Download File [164.9 kB]
  • FW-D-1011

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

  • HI/BPF 120-06 (CEJ 216P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=6")

    English

    Download File [672.3 kB]
  • HI/BP 105-02 (CEJ 310P)

    (Approval document / Joint)

    Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8")

    English

    Download File [643.7 kB]
  • HI/PHV 120-10 (CEJ 264P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with EIFS Finish and Steel Framing (Max. JW=8")

    English

    Download File [896.2 kB]
  • CW-S-2028

    (Approval document / Joint)

    Glass Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

    Download File [224.6 kB]
  • HW-D-0324

    (Firestop System Details / UL Detail Drawing)

    Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")

    English

    Download File [149.3 kB]
  • FW-D-1046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete stair case to Concrete wall joint (Max. JW=3-1/2")

    English

    Download File [206.5 kB]
  • HI/PHV 120-10 (CEJ 264P)

    (Approval document / Joint)

    Gypsum with EIFS Finish and Steel Framing (Max. JW=8")

    English

    Download File [527.4 kB]
  • FF-D-1001

    (Approval document / Joint)

    Concrete floor to concrete floor (floor to floor)

    English

  • FW-D-0041

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=1/2")

    English

    Download File [156.6 kB]
  • HW-D-0466

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to conrete floor joint (top-of-wall) (Max. JW=3/4") (The Steel Network)

    English

    Download File [254.6 kB]
  • CW-D-2046

    (Approval document / Joint)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [239.9 kB]
  • FW-D-1037

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=6")

    English

  • CW-S-1007

    (Approval document / Joint)

    Tilt-Up Concrete Panel Curtain Wall (Max JW = 6")

    English

    Download File [173 kB]
  • HI/BP 165-03 (CEJ 316P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Plaster Finish and Steel Framing (Max. JW=6")

    English

    Download File [619.5 kB]
  • FF-D-1001

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to concrete floor (floor to floor)

    English

  • HW-D-0530

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [336.2 kB]
  • HI/BP 120-05

    (Approval document / Joint)

    Gypsum with various facades. Steel framing starts and stops above and below floor (Max. JW=0") (Max. 2" cantilever)

    English

    Download File [909.4 kB]
  • FF-D-1012

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

    Download File [146.4 kB]
  • HW-D-0181

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")

    English

    Download File [43.5 kB]
  • CW-D-1003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=6")

    English

  • HW-D-0181

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=1")

    English

    Download File [107.4 kB]
  • HW-D-0440

    (Approval document / Joint)

    Concrete or block wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. JW=2")

    English

  • HW-D-0571

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to bottom of fireproofed steel beam to concrete over metal deck (top-of-wall) (Max. JW=1-1/2")

    English

    Download File [116.2 kB]
  • HW-D-0460

    (Approval document / Joint)

    Gypsum wall to conrete over metal deck (top-of-wall) (perpendicular) (Max. JW=3/4") (The Steel Network)

    English

    Download File [30 kB]
  • HI/PHV 120-09 (CEJ 263P)

    (Approval document / Joint)

    Gypsum with Aluminum or Steel Siding and Steel Framing (Max. JW=8")

    English

    Download File [526.8 kB]
  • HI/BP 105-01 (CEJ 309P)

    (Approval document / Joint)

    Glass Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [610.1 kB]
  • HW-D-0258

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")

    English

    Download File [241.4 kB]
  • CW-D-2046

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [127.5 kB]
  • HW-D-0292

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")

    English

    Download File [216.1 kB]
  • FW-D-0041

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max. JW=1/2")

    English

    Download File [96.3 kB]
  • HW-D-1003

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")

    English

    Download File [237.8 kB]
  • HI/BP 180-01 (CEJ 307P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass or Aluminum Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [1.8 MB]
  • HW-D-0046

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall)

    English

  • FW-D-1037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=6")

    English

  • CJ-D-0004

    (Approval document / Joint)

    Gypsum wall to non-rated floor/roof deck

    English

    Download File [28.5 kB]
  • CW-S-2029

    (Approval document / Joint)

    Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")

    English

  • HW-D-1002

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [166.7 kB]
  • HW-D-1001

    (Approval document / UL Detail Drawing)

    Concrete or block wall to flat concrete floor joint (one sided) (Max. JW=3-1/2")

    English

    Download File [241.3 kB]
  • FW-D-1011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

  • HI/BP 165-01 (CEJ 314P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum with Brick Finish and Steel Framing (Max. JW=6")

    English

    Download File [1.2 MB]
  • FF-D-1026

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

    Download File [86.1 kB]
  • CW-D-1018

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=3")

    English

    Download File [100.4 kB]
  • FW-D-0042

    (Approval document / Joint)

    Concrete floor to wall joint (Max. JW=2")

    English

    Download File [88.6 kB]
  • HW-D-0190

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=2")

    English

    Download File [212.1 kB]
  • HW-D-0530

    (Approval document / Joint)

    Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    English

    Download File [680.3 kB]
  • HW-D-0635

    (Firestop System Details / UL Detail Drawing)

    Gypsum Wall to bottom of offset I beam with Z-bar extensions w/ additional gypsum (Max. JW=1-1/2")

    English

    Download File [229.6 kB]
  • CW-D-2026

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass, Aluminum, or Granite Spandrel with Aluminum Framing (Max. JW=8")

    English

  • FF-D-1047

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to floor joint

    English

  • FF-D-0055

    (Approval document / Joint)

    Concrete floor to floor joint

    English

    Download File [87.9 kB]
  • HW-D-1009

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=3-3/4")

    English

    Download File [276 kB]
  • HI/BP 105-01 (CEJ 309P)

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with Aluminum Framing (Max. JW=8")

    English

    Download File [1.7 MB]
  • HW-D-0120

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")

    English

    Download File [600.2 kB]
  • HW-D-0396

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal roof deck (offset to flute) (Max. JW=3/4")

    English

    Download File [251.7 kB]
  • FW-D-1013

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max. JW=3-1/2")

    English

    Download File [108.2 kB]
  • HW-D-1003

    (Approval document / Joint)

    Concrete or block wall to flat concrete floor joint with max. 2" steel, cast iron, steel conduits, EMT penetrations (Max. JW=3-1/2")

    English

    Download File [71.4 kB]
  • FW-D-1001

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to concrete wall joint (Max. JW=6")

    English

  • CJ-D-0004

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to non-rated floor/roof deck

    English

    Download File [166.9 kB]
  • CW-D-1019

    (Approval document / Joint)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=4")

    English

    Download File [181 kB]
  • J-CS-TTS SA

    (Firestop System Details / UL Detail Drawing)

    Joint system for non-rated smoke partitions with CS-TTS SA Smoke & Acoustic Track Seal

    English

    Download File [364.6 kB]
  • BW-S-0040

    (Approval document / Joint)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [77.2 kB]
  • HW-D-0881

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [154 kB]
  • HW-D-1069

    (Approval document / Joint)

    Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [83.1 kB]
  • HW-S-0055

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)

    English

    Download File [159.8 kB]
  • HW-D-1104

    (CAD/BIM Typicals / Auto CAD drawing file)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [306 kB]
  • HW-D-0077

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")

    English

    Download File [189.3 kB]
  • HW-D-0119

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete over fluted metal deck or flat concrete (top-of-wall)

    English

    Download File [713.4 kB]
  • WW-D-0064

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [93.9 kB]
  • HW-S-0053

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [197.3 kB]
  • FW-D-1092

    (Firestop System Details / UL Detail Drawing)

    Concrete floor to wall joint (Max JW=3”)

    English

    Download File [20.4 kB]
  • WW-D-0141

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=1”)

    English

    Download File [244.5 kB]
  • WW-D-0017

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [78.5 kB]
  • HI/BPF 120-19

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=4-1/2")

    English

    Download File [3.4 MB]
  • HW-D-1104

    (Approval document / Joint)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [75.1 kB]
  • HW-D-1070

    (Firestop System Details / UL Detail Drawing)

    Block wall to underside of flat concrete (Max. JW=2-1/2")

    English

    Download File [100.3 kB]
  • WW-D-1011

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

  • WW-D-0032

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)

    English

    Download File [98.2 kB]
  • FW-D-0066

    (Approval document / Joint)

    Concrete stair case to concrete wall joint (Max JW=2”)

    English

    Download File [80.4 kB]
  • HW-S-0090

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")

    English

    Download File [212.8 kB]
  • HI/BPF 120-22

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")

    English

    Download File [136.5 kB]
  • FF-D-0096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint (Max JW = 2”)

    English

    Download File [238.4 kB]
  • HW-D-0061

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")

    English

  • WW-S-0042

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)

    English

    Download File [217.1 kB]
  • HW-D-0883

    (Approval document / Joint)

    Gypsum shaft wall to bottom of fire-proofed steel beam (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [150 kB]
  • HW-S-0053

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [488.3 kB]
  • HI/BPF 120-17

    (Approval document / Joint)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 4")

    English

    Download File [143.9 kB]
  • HW-D-1041

    (Approval document / Joint)

    Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-1020

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck (Max. JW=3")

    English

    Download File [706.8 kB]
  • HW-D-0702

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)

    English

    Download File [381 kB]
  • HW-D-0081

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [147.3 kB]
  • HW-S-0069

    (Approval document / Joint)

    Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")

    English

    Download File [69.9 kB]
  • WW-D-0017

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [113.6 kB]
  • HW-S-0055

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)

    English

    Download File [177.4 kB]
  • HI/BPF 120-17

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 4")

    English

    Download File [4.1 MB]
  • J-572/TP-572

    (CAD/BIM Typicals / Auto CAD drawing file)

    Joint details for non fire-rated smoke partitions with CP 572 Smoke & Acoustic Spray

    English

    Download File [243.3 kB]
  • HW-D-0703

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)

    English

    Download File [76 kB]
  • HW-D-1068

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to underside of flat concrete (Max. JW=2-1/2")

    English

    Download File [158.2 kB]
  • HW-D-1045

    (Approval document / Joint)

    Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-1044

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-1037

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")

    English

  • HW-D-0097

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall)

    English

  • HI/BPF 120-15

    (Approval document / Joint)

    Zero Spandrel (Alll Vision Glass) (Max. JW = 4")

    English

    Download File [126.2 kB]
  • WW-D-0141

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=1”)

    English

    Download File [20.7 kB]
  • HW-D-0076

    (Approval document / Joint)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")

    English

  • HW-S-0055

    (Approval document / Joint)

    Concrete or block wall to concrete floor or hollow core concrete (top-of-wall)

    English

    Download File [16.6 kB]
  • FW-D-1093

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max JW=3”)

    English

    Download File [263.9 kB]
  • HW-D-1042

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

  • HW-D-0882

    (Approval document / Joint)

    Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [125 kB]
  • WW-S-0048

    (Approval document / Joint)

    Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")

    English

    Download File [294.2 kB]
  • WW-D-1080

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=3")

    English

    Download File [114.5 kB]
  • WW-D-0220

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [293.5 kB]
  • HW-D-1070

    (CAD/BIM Typicals / Auto CAD drawing file)

    Block wall to underside of flat concrete (Max. JW=2-1/2")

    English

    Download File [248.4 kB]
  • HW-D-1041

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [167.1 kB]
  • HW-D-0083

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=3/4")

    English

    Download File [161.4 kB]
  • HW-D-0097

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall)

    English

    Download File [102 kB]
  • BW-S-0039

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [333.5 kB]
  • HI/BPF 120-21

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")

    English

    Download File [136 kB]
  • HW-S-0090

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")

    English

    Download File [87.4 kB]
  • WW-D-0140

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=2”)

    English

    Download File [20.8 kB]
  • HW-S-0145

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")

    English

    Download File [92.5 kB]
  • HI/BPF 120-16

    (Approval document / Joint)

    Zero spandrel (All Vision Glass) (Max. JW = 4")

    English

    Download File [118.3 kB]
  • WW-D-1128

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [289.7 kB]
  • HW-D-0632

    (Approval document / Joint)

    Gypsum wall to flat concrete (top-of-wall) (Max. JW=1”)

    English

    Download File [83.1 kB]
  • HW-D-1066

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall perpendicular to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [174.7 kB]
  • HI/BPF 120-19

    (Approval document / Joint)

    Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=4-1/2")

    English

    Download File [122.9 kB]
  • WW-D-0105

    (Approval document / Joint)

    Gypsum wall to concrete/block wall joint (Max. JW=1") (Polyethylene Backer Rod)

    English

    Download File [260.8 kB]
  • FF-D-0096

    (Approval document / Joint)

    Concrete floor to floor joint (Max JW = 2”)

    English

    Download File [72.7 kB]
  • HI/BPF 120-16

    (CAD/BIM Typicals / Auto CAD drawing file)

    Zero Spandrel (Alll Vision Glass) (Max. JW = 4")

    English

    Download File [626.6 kB]
  • WW-S-0048

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")

    English

    Download File [255.7 kB]
  • WW-D-0032

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)

    English

    Download File [77.1 kB]
  • HW-D-0061

    (Approval document / Joint)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")

    English

  • FF-D-1125

    (CAD/BIM Typicals / Auto CAD drawing file)

    maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.

    English

    Download File [239.7 kB]
  • HW-S-0134

    (Firestop System Details / UL Detail Drawing)

    English

  • HW-D-1070

    (Approval document / Joint)

    Block wall to underside of flat concrete (Max. JW=2-1/2")

    English

  • WW-S-0048

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to gypsum wall joint (gypsum sitting on top of block) (Max. JW=3/4")

    English

    Download File [22.3 kB]
  • WW-D-1012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max JW = 3-3/4")

    English

    Download File [117.9 kB]
  • HW-D-0081

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [193.8 kB]
  • HW-D-1068

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to underside of flat concrete (Max. JW=2-1/2")

    English

    Download File [177.2 kB]
  • HW-D-1044

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [166.9 kB]
  • HW-S-0134

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

  • FW-D-0066

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [243.2 kB]
  • HW-D-0085

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (includes Epic Metals deck) (top-of-wall) (Max. JW=3/4")

    English

    Download File [99.6 kB]
  • WW-D-0067

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to wall joint (Max JW = 2")

    English

    Download File [222.8 kB]
  • WW-D-1012

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max JW = 3-3/4")

    English

    Download File [162.8 kB]
  • HI/BPF 120-13

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 6")

    English

    Download File [2.3 MB]
  • HI/JF 120-03

    (Approval document / Joint)

    Gypsum Shaft Wall to Fireproofed Column Vertical Joint (Max. JW = 5/8")

    English

    Download File [311.5 kB]
  • HW-D-1068

    (Approval document / Joint)

    Gypsum wall to underside of flat concrete (Max. JW=2-1/2")

    English

  • WW-D-1129

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=3”)

    English

    Download File [20.9 kB]
  • HI/BPF 120-23

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")

    English

    Download File [1.1 MB]
  • FW-D-0067

    (Approval document / Joint)

    Concrete floor to wall joint (Max JW=1”)

    English

    Download File [73 kB]
  • HW-D-1045

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [109.7 kB]
  • HI/BPF 120-18

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=5")

    English

    Download File [4 MB]
  • WW-D-1128

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=3”)

    English

    Download File [246.3 kB]
  • HW-D-0702

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)

    English

    Download File [21 kB]
  • HW-D-0825

    (Approval document / Joint)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [84.9 kB]
  • WW-D-1012

    (Approval document / Joint)

    Concrete wall to wall joint (Max JW = 3-3/4")

    English

    Download File [79.8 kB]
  • HW-D-1041

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [148.9 kB]
  • FF-D-1126

    (CAD/BIM Typicals / Auto CAD drawing file)

    maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.

    English

    Download File [238.5 kB]
  • J-CS-TTS SA

    (CAD/BIM Typicals / Auto CAD drawing file)

    Joint system for non-rated smoke partitions with CS-TTS SA Smoke & Acoustic Track Seal

    English

    Download File [974.9 kB]
  • HI/BPF 120-23

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")

    English

    Download File [202 kB]
  • WW-D-1084

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

    Download File [87.2 kB]
  • WW-D-0105

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete/block wall joint (Max. JW=1") (Polyethylene Backer Rod)

    English

    Download File [226.6 kB]
  • HW-D-0097

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall)

    English

    Download File [98.7 kB]
  • HW-D-1058

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor (Max. JW=3-1/4")

    English

    Download File [113.6 kB]
  • HW-D-0089

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck w/ optional use of spray-on fireproofing (top-of-wall) (Max. JW=2")

    English

    Download File [40.6 kB]
  • BW-S-0039

    (Approval document / Joint)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [78.8 kB]
  • HW-D-0882

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [139.3 kB]
  • WW-D-0082

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=1")

    English

    Download File [106.2 kB]
  • WW-D-1080

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=3")

    English

    Download File [83.4 kB]
  • WW-D-1084

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

    Download File [74.4 kB]
  • HW-D-0003

    (Approval document / Joint)

    Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [703 kB]
  • HW-D-0883

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [693.6 kB]
  • HW-S-0090

    (Approval document / Joint)

    Gypsum wall to wood floor/ceiling assembly (Max. JW=1/2")

    English

    Download File [315 kB]
  • FF-D-0097

    (Approval document / Penetration)

    Concrete floor to floor joint (Max JW = 1”)

    English

    Download File [71.3 kB]
  • HW-D-1042

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

  • WW-D-0140

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=2”)

    English

    Download File [215.9 kB]
  • HW-D-0004

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [268.2 kB]
  • HW-D-0704

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [20.6 kB]
  • HW-D-1058

    (Approval document / Joint)

    Concrete or block wall to concrete floor (Max. JW=3-1/4")

    English

  • WW-D-0220

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [134.9 kB]
  • HW-D-1020

    (Approval document / Joint)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck (Max. JW=3")

    English

    Download File [114.4 kB]
  • HW-D-1044

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [111.2 kB]
  • FF-D-1126

    (Approval document / Joint)

    maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.

    English

    Download File [73.6 kB]
  • HW-D-0881

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [542.8 kB]
  • CW-D-1019

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tilt-up Concrete Panel Curtain Wall (Max. JW=4")

    English

    Download File [682 kB]
  • HI/JF 120-02

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum Wall-to-Fireproofed-Column Vertical Joint (Max. JW = 2-1/2")

    English

    Download File [561.6 kB]
  • HI/BPF 120-21

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 5")

    English

    Download File [1.1 MB]
  • WW-D-1047

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=2")

    English

  • HW-S-0054

    (Approval document / Joint)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [38.2 kB]
  • HW-D-0087

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck w/ optional use of spray-on fireproofing (top-of-wall) (Max. JW=2")

    English

    Download File [41.1 kB]
  • HW-D-1045

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor w/ steel bracing (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [113.7 kB]
  • HW-D-1067

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [194.3 kB]
  • HW-D-0098

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (penetrations in flutes) (Max. JW=1")

    English

  • HW-D-0881

    (Approval document / Joint)

    Gypsum shaft wall to concrete over metal deck (perpendicular) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [134 kB]
  • WW-D-1011

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

  • WW-S-0042

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)

    English

    Download File [101.1 kB]
  • HW-D-0931

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    English

    Download File [97 kB]
  • WW-D-0067

    (Approval document / Joint)

    Gypsum wall to wall joint (Max JW = 2")

    English

    Download File [77.2 kB]
  • HW-D-0703

    (CAD/BIM Typicals / Auto CAD drawing file)

    English

    Download File [366.9 kB]
  • HW-D-1037

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [166.9 kB]
  • HI/BPF 120-20

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")

    English

    Download File [136.8 kB]
  • HW-D-0119

    (Approval document / Joint)

    Gypsum wall to concrete over fluted metal deck or flat concrete (top-of-wall)

    English

    Download File [161.1 kB]
  • HW-D-1104

    (Firestop System Details / UL Detail Drawing)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [20.9 kB]
  • WW-D-1129

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=3”)

    English

    Download File [245.2 kB]
  • WW-S-0042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=1") (Exterior side sealed with 790 or 795 Dow Sealant, Pensil 300 Sealant, or Dynatrol II caulk or 864 Pecora Sealant)

    English

    Download File [299.9 kB]
  • HW-D-0704

    (Approval document / Joint)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)

    English

    Download File [74.9 kB]
  • HW-D-0004

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [384.9 kB]
  • BW-S-0039

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [116.8 kB]
  • WW-D-0082

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=1")

    English

    Download File [17.8 kB]
  • HW-D-1058

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete floor (Max. JW=3-1/4")

    English

    Download File [101.4 kB]
  • FW-D-1093

    (Approval document)

    English

    Download File [75.2 kB]
  • WW-D-0141

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=1”)

    English

    Download File [289.5 kB]
  • HI/BPF 120-14

    (Approval document / Joint)

    Zero Spandrel (All Vision Glass) (Max. JW = 4")

    English

    Download File [127.1 kB]
  • HW-S-0145

    (Approval document / Joint)

    Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")

    English

    Download File [74.8 kB]
  • HI/BPF 120-27

    (CAD/BIM Typicals / Auto CAD drawing file)

    Zero Spandrel (All Vision Glass) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4")

    English

    Download File [904.8 kB]
  • WW-D-1011

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

  • WW-D-0064

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [105.6 kB]
  • HW-D-0084

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over metal deck (top-of-wall) (Max. JW=3/4")

    English

  • FW-D-1092

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max JW=3”)

    English

    Download File [239.8 kB]
  • HW-D-1042

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    English

  • HW-D-1069

    (CAD/BIM Typicals / Auto CAD drawing file)

    Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [324.5 kB]
  • HW-D-1078

    (Approval document / Joint)

    Block wall to underside of flat concrete (Max. JW=3")

    English

    Download File [79.6 kB]
  • HW-D-0080

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

  • HW-D-0825

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [257.6 kB]
  • WW-D-1047

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=2")

    English

  • HW-D-0081

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

    Download File [102.2 kB]
  • J-572

    (Firestop System Details / UL Detail Drawing)

    Joint details for non fire-rated smoke partitions with CP 572 Smoke & Acoustic Spray

    English

    Download File [473.2 kB]
  • FF-D-0097

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint (Max JW = 1”)

    English

    Download File [141.5 kB]
  • HW-D-1067

    (Approval document / Joint)

    Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")

    English

  • HW-D-0118

    (Approval document / Joint)

    Gypsum wall to concrete over fluted metal deck (top-of-wall)

    English

    Download File [182.6 kB]
  • HI/BPF 120-14

    (CAD/BIM Typicals / Auto CAD drawing file)

    Zero Spandrel (All Vision Glass) (Max. JW = 4")

    English

    Download File [776 kB]
  • HI/BPF 120-10

    (Approval document / Joint)

    Zero Spandrel (All Vision Glass) (Max. JW = 4")

    English

    Download File [106.8 kB]
  • WW-D-1129

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=3”)

    English

    Download File [290.4 kB]
  • HW-D-0633

    (Approval document / Joint)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular or parallel) (Max. JW=1")

    English

    Download File [108.1 kB]
  • HW-D-0931

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    English

    Download File [324.9 kB]
  • HI/BPF 120-09

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 6") (Static Joint)

    English

    Download File [756.8 kB]
  • HW-D-1067

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall parallel to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [161.4 kB]
  • HW-D-0702

    (Approval document / Joint)

    Gypsum wall to flat concrete or hollow core (top-of-wall) (Max. JW=1”)

    English

    Download File [81.4 kB]
  • WW-D-0140

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=2”)

    English

    Download File [280.6 kB]
  • HI/BPF 120-15

    (CAD/BIM Typicals / Auto CAD drawing file)

    Zero Spandrel (Alll Vision Glass) (Max. JW = 4")

    English

    Download File [772.2 kB]
  • J-506/TP-506

    (CAD/BIM Typicals / Auto CAD drawing file)

    Joint details for non fire-rated smoke partitions with CP 506 Smoke & Acoustic Sealant or CP 605 Bottom-of-Wall Firestop Sealant

    English

    Download File [490.3 kB]
  • HW-S-0145

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to wood floor/ceiling assembly with CP 605 Bottom of Wall Firestop Sealant(Max. JW=1/2")

    English

    Download File [265.8 kB]
  • WW-D-0220

    (Approval document / Joint)

    Concrete wall to wall joint (one-sided install) with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [83.3 kB]
  • HW-S-0069

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")

    English

    Download File [310.8 kB]
  • WW-D-1047

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=2")

    English

  • WW-D-0082

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=1")

    English

    Download File [97.2 kB]
  • WW-D-0032

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=1") (CP 606 only, backer rod optional)

    English

    Download File [373.3 kB]
  • HW-D-0004

    (Approval document / Joint)

    Concrete or block wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [511.3 kB]
  • BW-S-0040

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [341.9 kB]
  • HW-D-0098

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (penetrations in flutes) (Max. JW=1")

    English

    Download File [227.3 kB]
  • HW-D-0082

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor (top-of-wall) (Max. JW=3/4")

    English

  • HW-D-0633

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete over metal deck (top-of-wall) (perpendicular or parallel) (Max. JW=1")

    English

    Download File [679.5 kB]
  • HW-D-1037

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3-1/2")

    English

    Download File [152.6 kB]
  • HI/JF 120-03

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum Shaft Wall to Fireproofed Column Vertical Joint (Max. JW = 5/8")

    English

    Download File [630.3 kB]
  • HW-D-1078

    (CAD/BIM Typicals / Auto CAD drawing file)

    Block wall to underside of flat concrete (Max. JW=3")

    English

    Download File [141.4 kB]
  • HW-D-0076

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")

    English

  • J-506-605

    (Firestop System Details / UL Detail Drawing)

    Joint details for non fire-rated smoke partitions with CP 506 Smoke & Acoustic Sealant or CP 605 Bottom-of-Wall Firestop Sealant

    English

    Download File [473.7 kB]
  • HI/BPF 120-27

    (Approval document / Joint)

    Zero Spandrel (All Vision Glass) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4")

    English

    Download File [141.7 kB]
  • WW-D-1084

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete wall to wall joint (Max. JW=3-1/2")

    English

    Download File [114.1 kB]
  • HW-D-0003

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [303.2 kB]
  • HI/BPF 120-18

    (Approval document / Joint)

    Glass Spandrel with Aluminum Framing (vision glass at floor) with CFS-EOS QS Edge of Slab Quick Seal (Max. JW=5")

    English

    Download File [119.9 kB]
  • FW-D-0067

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to wall joint (Max JW=1”)

    English

    Download File [93.8 kB]
  • WW-D-1080

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=3")

    English

    Download File [17.9 kB]
  • HI/BPF 120-13

    (Approval document / Joint)

    Glass Spandrel Panel with Aluminum Framing (Max JW = 6")

    English

    Download File [111.1 kB]
  • WW-D-1128

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=3”)

    English

    Download File [21.1 kB]
  • HI/BPF 120-22

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")

    English

    Download File [1.1 MB]
  • HW-D-1103

    (CAD/BIM Typicals / Auto CAD drawing file)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [310.5 kB]
  • FW-D-1092

    (Approval document / Joint)

    Concrete floor to wall joint (Max JW=3”)

    English

    Download File [74.7 kB]
  • WW-D-0017

    (Firestop System Details / UL Detail Drawing)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [98.9 kB]
  • BW-S-0040

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete floor (bottom-of-wall)

    English

    Download File [116.3 kB]
  • HW-D-1069

    (Firestop System Details / UL Detail Drawing)

    Block wall perpendicular/parallel to fluted metal deck (Max. JW=2-1/2")

    English

    Download File [96.4 kB]
  • HW-D-1103

    (Approval document / Joint)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [75.5 kB]
  • HW-D-0750

    (Firestop System Details / UL Detail Drawing)

    Gypsum shaft wall to concrete over metal deck (top-of-wall) (Max. JW=1-1/2")

    English

    Download File [393.8 kB]
  • HW-D-0703

    (Firestop System Details / UL Detail Drawing)

    English

    Download File [20.3 kB]
  • HW-S-0054

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [362.6 kB]
  • HW-D-1012

    (Approval document / Joint)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")

    English

    Download File [128.6 kB]
  • HW-D-0118

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete over fluted metal deck (top-of-wall)

    English

    Download File [1 MB]
  • HW-D-0080

    (Firestop System Details / UL Detail Drawing)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

  • HW-D-0704

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1”)

    English

    Download File [376.2 kB]
  • HW-D-1012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (Max. JW=3")

    English

    Download File [614.4 kB]
  • HW-S-0054

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [381.7 kB]
  • HW-D-0080

    (Approval document / Joint)

    Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    English

  • HI/JF 120-02

    (Approval document / Joint)

    Gypsum Wall-to-Fireproofed-Column Vertical Joint (Max. JW = 2-1/2")

    English

    Download File [389.3 kB]
  • HI/BPF 120-12

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 4")

    English

    Download File [598.5 kB]
  • HW-S-0053

    (Approval document / Joint)

    Gypsum wall to concrete floor or fluted metal roof deck (Max. JW=0")

    English

    Download File [136.7 kB]
  • HW-D-0003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall perpendicular to concrete over metal deck with max. 1-1/2” EMT/steel conduit through flutes (Max. JW=2")

    English

    Download File [364 kB]
  • HI/BPF 120-20

    (CAD/BIM Typicals / Auto CAD drawing file)

    Glass Spandrel Panel with Back Pan and Aluminum Framing with CFS-EOS QS Edge of Slab Quick Seal (Max. JW = 4-1/2")

    English

    Download File [1.1 MB]
  • WW-D-0220

    (Approval document / Joint)

    Concrete wall to wall joint (one-sided install) with optional max. 1" steel or pvc conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [83.1 kB]
  • HI/BPF 120-12

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 4")

    English

    Download File [121.6 kB]
  • HW-S-0069

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum wall to underside of offset I-beam with Z-bar extentions (Max. JW=1")

    English

    Download File [184 kB]
  • WW-D-0064

    (Approval document / Joint)

    Concrete wall to wall joint (Max. JW=2")

    English

    Download File [17.1 kB]
  • HW-D-0882

    (CAD/BIM Typicals / Auto CAD drawing file)

    Gypsum shaft wall to concrete over metal deck (parallel) (top-of-wall) with CFS-TTS MD Top Track Seal (Max. JW=1/2")

    English

    Download File [504.2 kB]
  • HI/BPF 120-10

    (CAD/BIM Typicals / Auto CAD drawing file)

    Zero Spandrel (All Vision Glass) (Max. JW = 4")

    English

    Download File [601.4 kB]
  • HW-D-0076

    (Firestop System Details / UL Detail Drawing)

    Gypsum wall to concrete over fluted metal deck (top-of-wall) (castle cut, gypsum cut to profile) (Max. JW=3/4")

    English

  • FF-D-1125

    (Approval document / Joint)

    maximum 3" Floor to Floor joint utilizinig mineral wool and CFS-S SIL GG or CFS-S SIL SL Firestop Silicone Sealant.

    English

    Download File [73.2 kB]
  • HW-S-0134

    (Approval document / Joint)

    English

  • HW-D-0825

    (Firestop System Details / UL Detail Drawing)

    Concrete wall/block wall to flat concrete floor (Includes Hollow-Core) one-sided install with optional max. 1" steel conduit penetrants (CFS-D 1" Firestop Putty Disc installed on each penetrant) (Max. JW=2")

    English

    Download File [101 kB]
  • HW-D-1078

    (Firestop System Details / UL Detail Drawing)

    Block wall to underside of flat concrete (Max. JW=3")

    English

    Download File [92 kB]
  • HW-D-1103

    (Firestop System Details / UL Detail Drawing)

    Block wall to underside of flat concrete or hollow core (Max. JW=3”)

    English

    Download File [20.4 kB]
  • HI/BPF 120-09

    (Approval document / Joint)

    Glass Spandrel Panel with Back Pan and Aluminum Framing (Max. JW = 6") (Static Joint)

    English

    Download File [424.6 kB]
  • HI/BPF 120-31

    (Approval document / Joint)

    Glass Spandrel Panel with Perimeter support angles, and aluminum framing. Treated with CFS-EOS QS Edge of Slab Quick Seal. (Max. JW = 5")

    English

    Download File [135.2 kB]
  • C-AJ-2021

    (Approval document / Penetration)

    Max. 6" PVC, ABS, CPVC, 4" FRPP or RNC, 3" Aquarise CPVC (optional hub on max. 4'"ABS)

    English

    Download File [88.1 kB]
  • C-AJ-5096

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")

    English

  • C-AJ-5096

    (Firestop System Details / UL Detail Drawing)

    Max. 12" steel, max. 6" copper with max. 1-1/2" glass fiber insulation (Steel sleeve optional) (2-1/2" concrete) (AS=1/2" to 1-7/8")

    English

  • HW-D-0929

    (Approval document / Joint)

    Concrete or block wall to concrete floor using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")

    English

    Download File [78.5 kB]
  • C-AJ-2024

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 2" PVC,  CPVC, or Aquarise CPVC  (knock-out sleeve)

    English

    Download File [206.5 kB]
  • C-AJ-3180

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve optional)

    English

  • C-AJ-5185

    (Approval document / Penetration)

    Max. 24" steel, cast iron, max. 4" copper with max. 3" thick mineral fiber insulation butted up to firestop assembly (AS=0" to 1-7/8")

    English

  • C-AJ-3138

    (Firestop System Details / UL Detail Drawing)

    Single cable (telephone cable)

    English

    Download File [164.8 kB]
  • C-AJ-3298

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)

    English

  • C-AJ-3138

    (Approval document / Penetration)

    Single cable (telephone cable)

    English

    Download File [20.5 kB]
  • C-AJ-5090

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" steel, copper pipe with max. 3/4" AB/PVC insulation (AS=1/2" to 2-1/4")

    English

  • C-AJ-3138

    (CAD/BIM Typicals / Auto CAD drawing file)

    Single cable (telephone cable)

    English

    Download File [99.9 kB]
  • C-AJ-5277

    (Approval document / Penetration)

    Max. 12" steel, 6" copper with nom. 1-1/2" or 3" thick Foam Glass pipe insulation in min. 2-1/2" concrete

    English

  • C-AJ-3298

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) through CP 653 Speed Sleeve (Unifrax Insulation)

    English

  • C-AJ-4034

    (Approval document / Penetration)

    Cable Tray

    English

    Download File [452.9 kB]
  • WW-D-0269

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete or block wall to concrete or block wall Using CFS-SP WB Firestop Joint Spray without overlap. (Max. JW=1")

    English

    Download File [332.9 kB]
  • FF-D-1216

    (CAD/BIM Typicals / Auto CAD drawing file)

    Concrete floor to floor joint with CFS-SP SIL Firestop Silicone Joint Spray (Max. JW=3")

    English

    Download File [339.7 kB]
  • C-AJ-5341

    (Approval document / Penetration)

    Max. 10" steel/cast iron with 1" to 3" glass fiber insulation (optional sleeve)

    English

    Download File [384.5 kB]
  • C-AJ-2071

    (Approval document / Penetration)

    Max. 2" Fusiotherm and Climatherm

    English

    Download File [88.8 kB]
  • HW-D-1125

    (Approval document / Joint)

    Gypsum wall (with RipTRAK) to concrete over fluted metal deck or flat concrete (Max. JW=4")

    English

    Download File [155.3 kB]
  • C-AJ-3284

    (Firestop System Details / UL Detail Drawing)

    Blank or cables (various cables) through CP 653 Speed Sleeve

    English

  • F-A-1003

    (CAD/BIM Typicals / Auto CAD drawing file)

    Tub Box with max. 1-1/2” Brass waste/overflow fittings (PVC drain)

    English

  • C-AJ-3180

    (CAD/BIM Typicals / Auto CAD drawing file)

    Cable bundle (various cables) (Steel sleeve optional)

    English

  • C-AJ-3216

    (Approval document / Penetration)

    Cable bundle (various cables) (Steel sleeve)

    English

    Download File [19.5 kB]
  • C-AJ-5044

    (Approval document / Penetration)

    Multiple insulated steel and copper pipes (max. 3")

    English

  • C-AJ-3284

    (CAD/BIM Typicals / Auto CAD drawing file)

    Blank or cables (various cables) through CP 653 Speed Sleeve

    English

  • C-AJ-3180

    (Firestop System Details / UL Detail Drawing)

    Cable bundle (various cables) (Steel sleeve optional)

    English